首页

> 学术发表知识库

首页 学术发表知识库 问题

火灾报警器论文参考文献

发布时间:

火灾报警器论文参考文献

摘要: 对火灾自动报警控制系统及智能火灾报警控制系统的特征进行了分析, 在高层建筑设 计中采用智能火灾报警控制系统的主—从式网络结构, 解决了高层建筑与大型建筑中探测区 域广、探测器数量多、原有系统不能适应等问题。 关键词:高层建筑 火灾自动报警 探测器 智能控制 联动控制 The design and application of automatic fire warning control system in high buidings Abstract: This article analyses the characteristics of the fire antomatic warning system and the intelligent fire warning control system. By using the sytem a lot of traditional problems can be solved, including using a lot of probes but cotrolling olny a relalively small area. Key words: high rised buiding; fire automatic warning system; probe; intelligent control; coordinated control system 随着我国经济建设的发展,现代高层建筑及重要建筑的防火问题引起了国家消防部门及设 计院等社会各界的高度重视。 国家制定了一系列防火规范, 从而促进火灾自动报警设备的研究和 推广使用。高层建筑建设规模大,装修标准高,人员密集,各种电气设备使用频繁,因而存在着 火灾隐患, 在建筑电气设计中必须严格依照规范要求设计火灾报警控制系统。 但选择何种控制系 统,使该系统充分有效地发挥功能,是设计中十分重要的问题。 1 火灾自动报警系统的主要部件及特征 火灾自动报警系统的基本形式有三种,即:区域报警系统、集中报警系统的控制中心报警系 统。高层建筑和大型建筑主要采用控制中心报警系统,这是一种复杂的火灾自动报警系统,主要 由触发器件、火灾报警装置、消防控制设备及电源组成。该系统从通报火灾到启动灭火系统和控 制各种消防设备,基本实现自动化。 触发器件 主要包括火灾探测器和手动火灾报警按钮。 火灾探测器是对火灾参数 (如烟、 温、 光、火焰辐射、气体浓度等)响应,并自动产生火灾报警信号的器件。按响应火灾参数的不同, 火灾探测器分为感温火灾探测器、感烟火灾探测器、气体火灾探测器、感光火灾探测器和复合火 灾探测器五种基本类型。 火灾报警装置 火灾报警装置 消防控制设备 在火灾自动报警系统中用以接收、 显示和传递火灾报警信号, 并能发生控制 在火灾自动报警系统中用以发出区别于环境声、光的火灾警报信号的装置, 在火灾自动报警系统中当接收到来自触发器件的火灾报警信号, 能自动或手 信号和具有其它辅助功能的控制指标设备。 如火灾警报器, 它是一种基本的火灾警报装置, 以声、 光音响方式向报警区域发出火灾警报信号。 动启动相关消防设施并显示其状态的设备。主要包括:火灾报警控制器;自动灭火系统的控制装 置;室内消火栓系统的控制装置;防排烟系统及空调通风系统的控制装置;常开防火门、防火卷 帘的控制装置;电梯回降控制装置以及火灾应急广播、火灾警报装置、消防通信设备、火灾应急 照明与疏散指示标志的控制装置等十类控制装置。 每个系统根据工程的需要应具有十类控制装置 的部分或全部。 电源 火灾自动报警系统属于消防用电设备,主电源采用消防电源,备用电源采用蓄电池, 保证不间断供电。 设计中消防控制设备主要设置在消防控制中心, 便于实行集中统一控制, 有些消防控制设备 可设在消防设备现场,而动作信号必须返回消防控制中心,实行集中与分散相结合的控制方式。 但该探测器有误报现象、控制器容量较小。 2 智能火灾报警控制系统工作原理 智能火灾报警控制系统与火灾自动报警系统不同之处在于: 将发生火灾期间所产生的烟、 温、 光等, 以模拟量形式连同外界相关的环境参量一起传送给报警器, 报警器再根据获取的数据及内 部存贮的大量数据,利用火灾判据来判断火灾是否存在。 智能火灾报警器中编址单元包括: 智能控测器、 智能手动按钮、 智能模块、 探测器并联接口、 总线隔离器和可编程继电器卡等。新型的智能火灾探测器,又称模拟量火灾探测器,这种探测器 给出的输出信号是代表被响应的火灾参数值的模拟量信号或其等效的数字信号。 传统探测器称为 有阈值火灾探测器,而智能火灾探测器没有阈值,却设有专用芯片,智能火灾探测器的应用提高 了报警系统的准确性和智能化程度。 在火灾报警时,报警控制器通过控制模块启动相应的外探设备,如排烟阀、送风阀、卷帘门 等,需要接受外控设备的反馈信号时,应加一个监视模块,控制模块和监视模块一样,联接在报 警回路总线上,安装在所控设备的附近。模块内设十进制编码开关,可现场编号,各占用回路总 线上一个地址。通过报警控制器显示控制模块和监视模块的具体地址,用声、光报警可反映联动 设备的工作状态。 可编程继电器卡,通过编程可实现对风机、水泵等大型设备的二级联动控制。智能控制是一 种无需人的干预就能够自主地驱动智能机器实现其目标的过程。 3 工程实例 火灾自动报警系统的设计应用 笔者 1992~1993 年参与设计的海南省物资局金属大厦,该大厦是座地下 1 层,地上 22 层, 建筑高度 70 多米,建筑面积 1.2 万平方米的写字楼。根据《高层民用建筑设计防火规范》的规 定,建筑高度超过 50 m 的办公楼属于一类防火建筑,因此该大厦要设火灾自动报警系统。 设计中选择了国产火灾自动报警系统,这种系统在当时较普遍,仅有一台主机控制器,因而 适用于中、小型建筑。 3.1 大厦消防控制中心设在 1 层,每层设层显示器。地下室作设备用房有变电室、空调机房、 水泵房,机房内设有防排烟风机、消防水泵等消防设备,当火灾发生时,温度达到一定值排 烟风机自动启动,并打开排烟阀,开始排烟(图 1)。 图1 排烟风机控制原理 该工程地下室是消防联动控制的集中点,将地下室的防排烟风机、排烟阀等控制线均引 至消防中心的联动控制器。消防泵、喷淋泵、正压风机、排烟风机、消防电梯等却属于外控 设备,均由联动控制器控制。整个火灾自动报警系统设计合理、运行可靠。 3.2 智能火灾报警系统的设计应用 随着科学技术的发展,智能火灾报警系统问世,从传统型走向智能型是国内外火灾报警 系统技术发展的必然趋势,工程设计人员必须予以充分重视。 徐州某大型建筑群由三栋塔楼组成,一栋为 25 层,一栋 13 层和一栋 12 层的塔楼由 4 层 裙楼连接而成,建筑面积 6 万平方米,建筑高度 85 m,主要功能:1 至 4 层为商场,5 层以上 为写字楼。由于该大厦建筑面积大,探测区域广,探测器数量非常可观。传统的火灾自动报 警系统已无法满足需要,因此,在设计中,经过反复的方案比较,选择了采用主—从式网结 构的智能火灾报警控制系统,该系统利用大容量的控制矩阵交叉查寻软件包,以软件编程代 替硬件组合,满足了大型工程的适用性,提高了消防联动的灵活性和可修改性。系统由主机、 从机、复示器等构成。该工程消防控制中心设于 1 层,主机和消防联动控制柜设在消防中心, 从机与复示器分设于楼层内。 智能探测器数量的确定 设计时先根据《火灾自动报警器系统设计规范》的规定确定探 测器的布局和设置。其规定探测区域内的每个房间至少应设置一只火灾探测器。感烟、感温 探测器的保护面积和保护半径应按表 1 确定。表中列出的是一个感烟探测器或感温探测器的 保护面积和保护半径。建筑物内往往一个探测区域的面积较大,超过一只探测器的保护面积, 这时需要计算一个探测区域内所需设置的探测器数量,可按下式计算: 式中:N 为一个探测区域内所需设置的探测器数量(只),N 取整数;S 为一个探测区域的面 积(m );A 为探测器的保护面积;K 为修正系数,重点保护建筑取 0.7~0.9,非重点保护建 筑取 1.0。 根据上式计算结果,可确定一个探测区内的智能探测器的安装数量。 选择控制器容量计算 该系统控制器为主—从式网络结构,每个主—从机系统,只能有 一台主机,从机数量根据工程要求确定,一般按探测器数量计算,从机数量最多为 15 台。 表1 感烟、感温探测器的保护面积和保护半径探测器的保护面积 A 和保护半径 R 火灾探测 器的种类 地面面积 S (m ) 2 2 房间高度 H (m) θ≤15° A (m ) 2 屋顶坡度 θ 15°<θ≤30° A (m ) 80 100 80 30 30 4.9 4.9 2 θ>30° A (m ) 80 120 100 30 40 2 R (m) 6/7 6.7 5.8 4.4 3.6 R (m) 7.2 8.0 7.2 R (m) 8.0 9.9 9.0 5.5 6.3 S≤80 感烟探测器 S>80 h≤12 6<h≤12 h≤6 80 80 60 30 20 感温探测器 S≤30 S>30 h≤8 h≤80 每台控制器最大有四个回路,每个回路容量均为 198 个地址,其中 99 个智能探测 器,99 个编址模块。因此一台主机或从机的最大容量为 4×99=396 个智能探测器, 4×99=396 个编址模块。 该工程经过计算,选用了一台主机和四台从机,每台控制器都按四个回路设计。 主机 N 控制 1~4 层商场内的所有探测器,手动报警按钮,控制按钮,水流指示器等消 防设备,从机 N1 控制地下室的所有探测器、送风阀、排烟阀、防火阀等消防设备,从 机 N2 控制 13 层和 12 层两座连通塔楼的 5~13 层的消防设备,N3、N4 分别控制 25 层 塔楼的 5~13 层和 14~25 层的消防设备。 整个大厦智能火灾报警控制系统设计比较合理,充分考虑到建筑群的特点,选用 一台主机、四台从机控制了 6 万平方米的建筑,如果用传统火灾自动报警系统则需要 几套控制系统分别控制,现有系统设计即经济实用,又准确可靠。 4 结论 综合上述工程设计与实践研究,可以得出以下几点认识与结论。 1) 传统的火灾自动报警系统适合于中、 小型建筑, 它的特点是探测器属于阀值型, 控制器仅有主机一台。而智能火灾报警控制系统,采用模拟量探测器,控制系统采用 主—从式网络结构,适应性强,尤其适合大型建筑的火灾报警系统。 2)智能火灾报警系统,克服了传统火灾自动报警系统存在的漏报和误报的难题, 提高了报警系统的准确性、可靠性。在设计中可灵活应用,根据工程需要选择适当的 从机数量,使工程设计最经济、最合理。 3)为了防患于未然,火灾报警系统的设计和应用十分重要,设计人员应根据不同 的建筑工程,优化设计方案。 参考文献:〔1〕 蔡自兴, 徐光礻 〔2〕 右.人工智能及其应用 〔M〕 .北京: 清华大学出版社, 1996,329~ 360 戴汝为.智能系统的综合集成〔M〕.杭州:浙江科学技术出版社,1995,128~ 160 〔3〕 陈一才.大楼自动化系统设计手册 〔M〕 .北京: 中国建筑工业出版社, 1994,230~ 270 〔4〕 王根堂.公安消防监督员业务培训教材,群众出版社,1997,213~236

原创论文,包通过,包修改。

1. 基于FX2N-48MRPLC的交通灯控制2. 西门子PLC控制的四层电梯毕业设计论文3. PLC电梯控制毕业论文4. 基于plc的五层电梯控制5. 松下PLC控制的五层电梯设计6. 基于PLC控制的立体车库系统设计7. PLC控制的花样喷泉8. 三菱PLC控制的花样喷泉系统9. PLC控制的抢答器设计10. 世纪星组态 PLC控制的交通灯系统11. X62W型卧式万能铣床设计12. 四路抢答器PLC控制13. PLC控制类毕业设计论文14. 铁路与公路交叉口护栏自动控制系统15. 基于PLC的机械手自动操作系统16. 三相异步电动机正反转控制17. 基于机械手分选大小球的自动控制18. 基于PLC控制的作息时间控制系统19. 变频恒压供水控制系统20. PLC在电网备用自动投入中的应用21. PLC在变电站变压器自动化中的应用22. FX2系列PCL五层电梯控制系统23. PLC控制的自动售货机毕业设计论文24. 双恒压供水西门子PLC毕业设计25. 交流变频调速PLC控制电梯系统设计毕业论文26. 基于PLC的三层电梯控制系统设计27. PLC控制自动门的课程设计28. PLC控制锅炉输煤系统29. PLC控制变频调速五层电梯系统设计30. 机械手PLC控制设计31. 基于PLC的组合机床控制系统设计32. PLC在改造z-3040型摇臂钻床中的应用33. 超高压水射流机器人切割系统电气控制设计34. PLC在数控技术中进给系统的开发中的应用35. PLC在船用牵引控制系统开发中的应用36. 智能组合秤控制系统设计37. S7-200PLC在数控车床控制系统中的应用38. 自动送料装车系统PLC控制设计39. 三菱PLC在五层电梯控制中的应用40. PLC在交流双速电梯控制系统中的应用41. PLC电梯控制毕业论文42. 基于PLC的电机故障诊断系统设计43. 欧姆龙PLC控制交通灯系统毕业论文44. PLC在配料生产线上的应用毕业论文45. 三菱PLC控制的四层电梯毕业设计论文46. 全自动洗衣机PLC控制毕业设计论文47. 工业洗衣机的PLC控制毕业论文48. 《双恒压无塔供水的PLC电气控制》49. 基于三菱PLC设计的四层电梯控制系统50. 西门子PLC交通灯毕业设计51. 自动铣床PLC控制系统毕业设计52. PLC变频调速恒压供水系统53. PLC控制的行车自动化控制系统54. 基于PLC的自动售货机的设计55. 基于PLC的气动机械手控制系统56. PLC在电梯自动化控制中的应用57. 组态控制交通灯58. PLC控制的升降横移式自动化立体车库59. PLC在电动单梁天车中的应用60. PLC在液体混合控制系统中的应用61. 基于西门子PLC控制的全自动洗衣机仿真设计62. 基于三菱PLC控制的全自动洗衣机63. 基于plc的污水处理系统64. 恒压供水系统的PLC控制设计65. 基于欧姆龙PLC的变频恒压供水系统设计66. 西门子PLC编写的花样喷泉控制程序67. 欧姆龙PLC编写的全自动洗衣机控制程序68 景观温室控制系统的设计69. 贮丝生产线PLC控制的系统70. 基于PLC的霓虹灯控制系统71. PLC在砂光机控制系统上的应用72. 磨石粉生产线控制系统的设计73. 自动药片装瓶机PLC控制设计74. 装卸料小车多方式运行的PLC控制系统设计75. PLC控制的自动罐装机系统76. 基于CPLD的可控硅中频电源77. 西门子PLC编写的花样喷泉控制程序78. 欧姆龙PLC编写的全自动洗衣机控制程序79. PLC在板式过滤器中的应用80. PLC在粮食存储物流控制系统设计中的应用81. 变频调速式疲劳试验装置控制系统设计82. 基于PLC的贮料罐控制系统83. 基于PLC的智能交通灯监控系统设计1.基于labVIEW虚拟滤波器的设计与实现2.双闭环直流调速系统设计3.单片机脉搏测量仪4.单片机控制的全自动洗衣机毕业设计论文5.FPGA电梯控制的设计与实现6.恒温箱单片机控制7.基于单片机的数字电压表8.单片机控制步进电机毕业设计论文9.函数信号发生器设计论文10.110KV变电所一次系统设计11.报警门铃设计论文12.51单片机交通灯控制13.单片机温度控制系统14.CDMA通信系统中的接入信道部分进行仿真与分析15.仓库温湿度的监测系统16.基于单片机的电子密码锁17.单片机控制交通灯系统设计18.基于DSP的IIR数字低通滤波器的设计与实现19.智能抢答器设计20.基于LabVIEW的PC机与单片机串口通信21.DSP设计的IIR数字高通滤波器22.单片机数字钟设计23.自动起闭光控窗帘毕业设计论文24.三容液位远程测控系统毕业论文25.基于Matlab的PWM波形仿真与分析26.集成功率放大电路的设计27.波形发生器、频率计和数字电压表设计28.水位遥测自控系统 毕业论文29.宽带视频放大电路的设计 毕业设计30.简易数字存储示波器设计毕业论文31.球赛计时计分器 毕业设计论文32.IIR数字滤波器的设计毕业论文33.PC机与单片机串行通信毕业论文34.基于CPLD的低频信号发生器设计毕业论文35.110kV变电站电气主接线设计36.m序列在扩频通信中的应用37.正弦信号发生器38.红外报警器设计与实现39.开关稳压电源设计40.基于MCS51单片机温度控制毕业设计论文41.步进电动机竹竿舞健身娱乐器材42.单片机控制步进电机 毕业设计论文43.单片机汽车倒车测距仪44.基于单片机的自行车测速系统设计45.水电站电气一次及发电机保护46.基于单片机的数字显示温度系统毕业设计论文47.语音电子门锁设计与实现48.工厂总降压变电所设计-毕业论文49.单片机无线抢答器设计50.基于单片机控制直流电机调速系统毕业设计论文51.单片机串行通信发射部分毕业设计论文52.基于VHDL语言PLD设计的出租车计费系统毕业设计论文53.超声波测距仪毕业设计论文54.单片机控制的数控电流源毕业设计论文55.声控报警器毕业设计论文56.基于单片机的锁相频率合成器毕业设计论文57.基于Multism/protel的数字抢答器58.单片机智能火灾报警器毕业设计论59.无线多路遥控发射接收系统设计毕业论文60.单片机对玩具小车的智能控制毕业设计论文61.数字频率计毕业设计论文62.基于单片机控制的电机交流调速毕业设计论文63.楼宇自动化--毕业设计论文64.车辆牌照图像识别算法的实现--毕业设计65.超声波测距仪--毕业设计66.工厂变电所一次侧电气设计67.电子测频仪--毕业设计68.点阵电子显示屏--毕业设计69.电子电路的电子仿真实验研究70.基于51单片机的多路温度采集控制系统71.基于单片机的数字钟设计72.小功率不间断电源(UPS)中变换器的原理与设计73.自动存包柜的设计74.空调器微电脑控制系统75.全自动洗衣机控制器76.电力线载波调制解调器毕业设计论文77.图书馆照明控制系统设计78.基于AC3的虚拟环绕声实现79.电视伴音红外转发器的设计80.多传感器障碍物检测系统的软件设计81.基于单片机的电器遥控器设计82.基于单片机的数码录音与播放系统83.单片机控制的霓虹灯控制器84.电阻炉温度控制系统85.智能温度巡检仪的研制86.保险箱遥控密码锁 毕业设计87.10KV变电所的电气部分及继电保护88.年产26000吨乙醇精馏装置设计89.卷扬机自动控制限位控制系统90.铁矿综合自动化调度系统91.磁敏传感器水位控制系统92.继电器控制两段传输带机电系统93.广告灯自动控制系统94.基于CFA的二阶滤波器设计95.霍尔传感器水位控制系统96.全自动车载饮水机97.浮球液位传感器水位控制系统98.干簧继电器水位控制系统99.电接点压力表水位控制系统100.低成本智能住宅监控系统的设计101.大型发电厂的继电保护配置102.直流操作电源监控系统的研究103.悬挂运动控制系统104.气体泄漏超声检测系统的设计105.电压无功补偿综合控制装置106.FC-TCR型无功补偿装置控制器的设计107.DSP电机调速108.150MHz频段窄带调频无线接收机109.电子体温计110.基于单片机的病床呼叫控制系统111.红外测温仪112.基于单片微型计算机的测距仪113.智能数字频率计114.基于单片微型计算机的多路室内火灾报警器115.信号发生器116.基于单片微型计算机的语音播出的作息时间控制器117.交通信号灯控制电路的设计118.基于单片机步进电机控制系统设计119.多路数据采集系统的设计120.电子万年历121.遥控式数控电源设计122.110kV降压变电所一次系统设计123.220kv变电站一次系统设计124.智能数字频率计125.信号发生器126.基于虚拟仪器的电网主要电气参数测试设计127.基于FPGA的电网基本电量数字测量系统的设计128.风力发电电能变换装置的研究与设计129.电流继电器设计130.大功率电器智能识别与用电安全控制器的设计131.交流电机型式试验及计算机软件的研究132.单片机交通灯控制系统的设计133.智能立体仓库系统的设计134.智能火灾报警监测系统135.基于单片机的多点温度检测系统136.单片机定时闹钟设计137.湿度传感器单片机检测电路制作138.智能小车自动寻址设计--小车悬挂运动控制系统139.探讨未来通信技术的发展趋势140.音频多重混响设计141.单片机呼叫系统的设计142.基于FPGA和锁相环4046实现波形发生器143.基于FPGA的数字通信系统144.基于单片机的带智能自动化的红外遥控小车145.基于单片机AT89C51的语音温度计的设计146.智能楼宇设计147.移动电话接收机功能电路148.单片机演奏音乐歌曲装置的设计149.单片机电铃系统设计150.智能电子密码锁设计151.八路智能抢答器设计152.组态控制抢答器系统设计153.组态控制皮带运输机系统设计154..基于单片机控制音乐门铃155.基于单片机控制文字的显示156.基于单片机控制发生的数字音乐盒157.基于单片机控制动态扫描文字显示系统的设计158.基于LMS自适应滤波器的MATLAB实现159.D功率放大器毕业论文160.无线射频识别系统发射接收硬件电路的设计161.基于单片机PIC16F877的环境监测系统的设计162.基于ADE7758的电能监测系统的设计163.智能电话报警器164.数字频率计 课程设计165.多功能数字钟电路设计 课程设计166.基于VHDL数字频率计的设计与仿真167.基于单片机控制的电子秤168.基于单片机的智能电子负载系统设计169.电压比较器的模拟与仿真170.脉冲变压器设计171.MATLAB仿真技术及应用172.基于单片机的水温控制系统173.基于FPGA和单片机的多功能等精度频率计174.发电机-变压器组中微型机保护系统175.基于单片机的鸡雏恒温孵化器的设计176.数字温度计的设计177.生产流水线产品产量统计显示系统178.水位报警显时控制系统的设计179.红外遥控电子密码锁的设计180.基于MCU温控智能风扇控制系统的设计181.数字电容测量仪的设计182.基于单片机的遥控器的设计183.200电话卡代拨器的设计184.数字式心电信号发生器硬件设计及波形输出实现185.电压稳定毕业设计论文186.基于DSP的短波通信系统设计(IIR设计)187.一氧化碳报警器188.网络视频监控系统的设计189.全氢罩式退火炉温度控制系统190.通用串行总线数据采集卡的设计191.单片机控制单闭环直流电动机的调速控制系统192.单片机电加热炉温度控制系统193.单片机大型建筑火灾监控系统194.USB接口设备驱动程序的框架设计195.基于Matlab的多频率FMICW的信号分离及时延信息提取196.正弦信号发生器197.小功率UPS系统设计198.全数字控制SPWM单相变频器199.点阵式汉字电子显示屏的设计与制作200.基于AT89C51的路灯控制系统设计200.基于AT89C51的路灯控制系统设计201.基于AT89C51的宽范围高精度的电机转速测量系统202.开关电源设计203.基于PDIUSBD12和K9F2808简易USB闪存设计204.微型机控制一体化监控系统205.直流电机试验自动采集与控制系统的设计206.新型自动装弹机控制系统的研究与开发207.交流异步电机试验自动采集与控制系统的设计208.转速闭环控制的直流调速系统的仿真与设计209.基于单片机的数字直流调速系统设计210.多功能频率计的设计211.18信息移频信号的频谱分析和识别212.集散管理系统—终端设计213.基于MATLAB的数字滤波器优化设计214.基于AT89C51SND1C的MP3播放器215.基于光纤的汽车CAN总线研究216.汽车倒车雷达217.基于DSP的电机控制218.超媒体技术219.数字电子钟的设计与制作220.温度报警器的电路设计与制作221.数字电子钟的电路设计222.鸡舍电子智能补光器的设计223.高精度超声波传感器信号调理电路的设计224.电子密码锁的电路设计与制作225.单片机控制电梯系统的设计226.常用电器维修方法综述227.控制式智能计热表的设计228.电子指南针设计229.汽车防撞主控系统设计230.单片机的智能电源管理系统231.电力电子技术在绿色照明电路中的应用232.电气火灾自动保护型断路器的设计233.基于单片机的多功能智能小车设计234.对漏电保护器安全性能的剖析235.解析民用建筑的应急照明236.电力拖动控制系统设计237.低频功率放大器设计238.银行自动报警系统

正好我刚做好了,过两天也要交了,论文,仿真,还有PPt,不是一个学校的话可以发给你QQ1255324803

火灾报警器毕业论文

以下均可参考,从参考网址进入,合适的话,给我加分!谢谢1.基于labVIEW虚拟滤波器的设计与实现 2.双闭环直流调速系统设计3.单片机脉搏测量仪 4.单片机控制的全自动洗衣机毕业设计论文5.FPGA电梯控制的设计与实现 6.恒温箱单片机控制7.基于单片机的数字电压表 8.单片机控制步进电机毕业设计论文9.函数信号发生器设计论文 10.110KV变电所一次系统设计11.报警门铃设计论文 12.51单片机交通灯控制13.单片机温度控制系统 14.CDMA通信系统中的接入信道部分进行仿真与分析15.仓库温湿度的监测系统 16.基于单片机的电子密码锁17.单片机控制交通灯系统设计 18.基于DSP的IIR数字低通滤波器的设计与实现19.智能抢答器设计 20.基于LabVIEW的PC机与单片机串口通信21.DSP设计的IIR数字高通滤波器 22.单片机数字钟设计23.自动起闭光控窗帘毕业设计论文 24.三容液位远程测控系统毕业论文25.基于Matlab的PWM波形仿真与分析 26.集成功率放大电路的设计27.波形发生器、频率计和数字电压表设计 28.水位遥测自控系统 毕业论文29.宽带视频放大电路的设计 毕业设计 30.简易数字存储示波器设计毕业论文31.球赛计时计分器 毕业设计论文 32.IIR数字滤波器的设计毕业论文33.PC机与单片机串行通信毕业论文 34.基于CPLD的低频信号发生器设计毕业论文35.110kV变电站电气主接线设计 36.m序列在扩频通信中的应用37.正弦信号发生器 38.红外报警器设计与实现39.开关稳压电源设计 40.基于MCS51单片机温度控制毕业设计论文41.步进电动机竹竿舞健身娱乐器材 42.单片机控制步进电机 毕业设计论文43.单片机汽车倒车测距仪 44.基于单片机的自行车测速系统设计45.水电站电气一次及发电机保护 46.基于单片机的数字显示温度系统毕业设计论文47.语音电子门锁设计与实现 48.工厂总降压变电所设计-毕业论文49.单片机无线抢答器设计 50.基于单片机控制直流电机调速系统毕业设计论文51.单片机串行通信发射部分毕业设计论文 52.基于VHDL语言PLD设计的出租车计费系统毕业设计论文53.超声波测距仪毕业设计论文 54.单片机控制的数控电流源毕业设计论文55.声控报警器毕业设计论文 56.基于单片机的锁相频率合成器毕业设计论文57.基于Multism/protel的数字抢答器 58.单片机智能火灾报警器毕业设计论59.无线多路遥控发射接收系统设计毕业论文 60.单片机对玩具小车的智能控制毕业设计论文61.数字频率计毕业设计论文 62.基于单片机控制的电机交流调速毕业设计论文63.楼宇自动化--毕业设计论文 64.车辆牌照图像识别算法的实现--毕业设计65.超声波测距仪--毕业设计 66.工厂变电所一次侧电气设计67.电子测频仪--毕业设计 68.点阵电子显示屏--毕业设计69.电子电路的电子仿真实验研究 70.基于51单片机的多路温度采集控制系统71.基于单片机的数字钟设计 72.小功率不间断电源(UPS)中变换器的原理与设计73.自动存包柜的设计 74.空调器微电脑控制系统75.全自动洗衣机控制器 76.电力线载波调制解调器毕业设计论文77.图书馆照明控制系统设计 78.基于AC3的虚拟环绕声实现79.电视伴音红外转发器的设计 80.多传感器障碍物检测系统的软件设计81.基于单片机的电器遥控器设计 82.基于单片机的数码录音与播放系统83.单片机控制的霓虹灯控制器 84.电阻炉温度控制系统85.智能温度巡检仪的研制 86.保险箱遥控密码锁 毕业设计87.10KV变电所的电气部分及继电保护 88.年产26000吨乙醇精馏装置设计89.卷扬机自动控制限位控制系统 90.铁矿综合自动化调度系统91.磁敏传感器水位控制系统 92.继电器控制两段传输带机电系统93.广告灯自动控制系统 94.基于CFA的二阶滤波器设计95.霍尔传感器水位控制系统 96.全自动车载饮水机97.浮球液位传感器水位控制系统 98.干簧继电器水位控制系统99.电接点压力表水位控制系统 100.低成本智能住宅监控系统的设计101.大型发电厂的继电保护配置 102.直流操作电源监控系统的研究103.悬挂运动控制系统 104.气体泄漏超声检测系统的设计105.电压无功补偿综合控制装置 106.FC-TCR型无功补偿装置控制器的设计107.DSP电机调速 108.150MHz频段窄带调频无线接收机109.电子体温计 110.基于单片机的病床呼叫控制系统111.红外测温仪 112.基于单片微型计算机的测距仪113.智能数字频率计 114.基于单片微型计算机的多路室内火灾报警器115.信号发生器 116.基于单片微型计算机的语音播出的作息时间控制器117.交通信号灯控制电路的设计 118.基于单片机步进电机控制系统设计119.多路数据采集系统的设计 120.电子万年历 121.遥控式数控电源设计 122.110kV降压变电所一次系统设计 123.220kv变电站一次系统设计 124.智能数字频率计 125.信号发生器126.基于虚拟仪器的电网主要电气参数测试设计 127.基于FPGA的电网基本电量数字测量系统的设计 128.风力发电电能变换装置的研究与设计 129.电流继电器设计 130.大功率电器智能识别与用电安全控制器的设计 131.交流电机型式试验及计算机软件的研究 132.单片机交通灯控制系统的设计 133.智能立体仓库系统的设计 134.智能火灾报警监测系统 135.基于单片机的多点温度检测系统 136.单片机定时闹钟设计 137.湿度传感器单片机检测电路制作 138.智能小车自动寻址设计--小车悬挂运动控制系统 139.探讨未来通信技术的发展趋势 140.音频多重混响设计 141.单片机呼叫系统的设计 142.基于FPGA和锁相环4046实现波形发生器 143.基于FPGA的数字通信系统 144.基于单片机的带智能自动化的红外遥控小车 145.基于单片机AT89C51的语音温度计的设计 146.智能楼宇设计 147.移动电话接收机功能电路 148.单片机演奏音乐歌曲装置的设计 149.单片机电铃系统设计 150.智能电子密码锁设计 151.八路智能抢答器设计 152.组态控制抢答器系统设计 153.组态控制皮带运输机系统设计 154..基于单片机控制音乐门铃 155.基于单片机控制文字的显示 156.基于单片机控制发生的数字音乐盒 157.基于单片机控制动态扫描文字显示系统的设计 158.基于LMS自适应滤波器的MATLAB实现 159.D功率放大器毕业论文 160.无线射频识别系统发射接收硬件电路的设计 161.基于单片机PIC16F877的环境监测系统的设计 162.基于ADE7758的电能监测系统的设计 163.智能电话报警器 164.数字频率计 课程设计 165.多功能数字钟电路设计 课程设计 166.基于VHDL数字频率计的设计与仿真 167.基于单片机控制的电子秤 168.基于单片机的智能电子负载系统设计 169.电压比较器的模拟与仿真 170.脉冲变压器设计 171.MATLAB仿真技术及应用 172.基于单片机的水温控制系统 173.基于FPGA和单片机的多功能等精度频率计 174.发电机-变压器组中微型机保护系统 175.基于单片机的鸡雏恒温孵化器的设计 176.数字温度计的设计 177.生产流水线产品产量统计显示系统 178.水位报警显时控制系统的设计 179.红外遥控电子密码锁的设计 180.基于MCU温控智能风扇控制系统的设计 181.数字电容测量仪的设计 182.基于单片机的遥控器的设计 183.200电话卡代拨器的设计 184.数字式心电信号发生器硬件设计及波形输出实现 185.电压稳定毕业设计论文 186.基于DSP的短波通信系统设计(IIR设计) 187.一氧化碳报警器 188.网络视频监控系统的设计 189.全氢罩式退火炉温度控制系统 190.通用串行总线数据采集卡的设计 191.单片机控制单闭环直流电动机的调速控制系统 192.单片机电加热炉温度控制系统 193.单片机大型建筑火灾监控系统 194.USB接口设备驱动程序的框架设计 195.基于Matlab的多频率FMICW的信号分离及时延信息提取 196.正弦信号发生器 197.小功率UPS系统设计 198.全数字控制SPWM单相变频器 199.点阵式汉字电子显示屏的设计与制作 200.基于AT89C51的路灯控制系统设计 200.基于AT89C51的路灯控制系统设计 201.基于AT89C51的宽范围高精度的电机转速测量系统 202.开关电源设计203.基于PDIUSBD12和K9F2808简易USB闪存设计 204.微型机控制一体化监控系统205.直流电机试验自动采集与控制系统的设计 206.新型自动装弹机控制系统的研究与开发 207.交流异步电机试验自动采集与控制系统的设计208.转速闭环控制的直流调速系统的仿真与设计209.基于单片机的数字直流调速系统设计210.多功能频率计的设计211.18信息移频信号的频谱分析和识别212.集散管理系统—终端设计213.基于MATLAB的数字滤波器优化设计214.基于AT89C51SND1C的MP3播放器215.基于光纤的汽车CAN总线研究216.汽车倒车雷达217.基于DSP的电机控制218.超媒体技术219.数字电子钟的设计与制作220.温度报警器的电路设计与制作221.数字电子钟的电路设计222.鸡舍电子智能补光器的设计223.高精度超声波传感器信号调理电路的设计224.电子密码锁的电路设计与制作225.单片机控制电梯系统的设计226.常用电器维修方法综述227.控制式智能计热表的设计228.电子指南针设计229.汽车防撞主控系统设计230.单片机的智能电源管理系统231.电力电子技术在绿色照明电路中的应用232.电气火灾自动保护型断路器的设计233.基于单片机的多功能智能小车设计234.对漏电保护器安全性能的剖析235.解析民用建筑的应急照明236.电力拖动控制系统设计237.低频功率放大器设计238.银行自动报警系统

大学是干嘛的地方?无论多高的学历和职称,不会设计、制造教具,不会设计、制造教学仪器,不会维修仪器和设备;用你父母的钱进口教学仪器模仿了委托工厂仿制就是佼佼者;用你父母的钱请校外的人来维修设备、从校外采购配件;用你父母的钱请教学仪器生产企业提供教学实验讲义,将作者填上他们的名字就有教学突出成就奖;教你背诵的公式和外语,永远也比不上美国麻省理工学院在网上公开的教材内容。学生也不要埋怨学费贵,除了上面教师的原因,你们自己的基础实验、专业课就上的迷迷糊糊的,高额投资下的创新实验项目、挑战杯、科技竞赛、毕业论文、商业开发,都见不得阳光,将真金白银变成了一堆堆的垃圾!!!!

电子信息工程的 毕业 论文写作中,论文的题目起着画龙点睛的作用,要重视论文的题目。下面是我带来的关于电子信息工程毕业论文题目的内容,欢迎阅读参考!电子信息工程毕业论文题目(一) 1. 基于80C51的智能汽车自控系统的设计 2. PLC实现十字路交通灯自动控制 3. 智能型充电器的电源和显示设计 4. 基于单片机的电子时钟设计及应用 5. 基于单片机的智能电子时钟的设计及应用 6. 超外差中波调幅收音机组装及调试 7. 基于USB接口的步进电机控制的研究与实现 8. 基于单片机的电子琴设计 9. 基于FPGA的直序扩频通信研究与设计 10. 基于单片机的发射机控制系统 11. 声光报警器的设计与研究 12. 单片机电源 13. 基于P87LPC768的电机控制系统 14. 基于单片机的LCD电子钟设计 15. 音响放大器的设计 16. 超外差收音机制作及分析研究 17. 2DPSK频带传输系统的设计与实现 18. 基于单片机智能电子钟的设计 19. USB与串行接口转换器的设计 20. 基于FPGA的数字频率计的设计 电子信息工程毕业论文题目(二) 1. 家庭防盗报警系统 2. 单片机实现单步进电机及8位流水灯控制的设计 3. 篮球 竞赛计时系统 4. 单片机89C51在直流调速控制系统中的应用 5. 八路数字抢答器 6. 基于51机的直流电机设计 7. 基于51单片机的步进电机控制系统 8. 基于一种DC-DC模块电源系统的设计 9. 基于555定时器闪光灯的设计 10. 多功能稳压电源的制作 11. 直流稳压电源的制作 12. 步进电机的单片机控制系统 13. 单片机交通灯管理系统 14. AT89S51单片机交通灯控制系统制作 15. 基于单片机的步进电机系统设计 16. 基于WML的学生网站开发 17. 基于单片机的电子密码锁 18. 单片机驱动步进电机控制系统的设计 19. 基于单片机的流水灯设计 电子信息工程毕业论文题目(三) 1. 基于单片机的火灾报警器设计 2. 基于NE555的触摸式报警器 3. 数字密码锁设计 4. 基于单片机智能电子时钟设计及应用 5. 流水灯控制电路设计 6. 简易单片机控制电路实验开发板 7. 全自动洗衣机自动控制电路部分设计 8. 基于单片机的八路抢答器的设计及PCB板的设计 9. 基于单片机的数字温度计的设计 10. 仓库温湿度的监测系统 11. 电子门铃的设计 12. 基于单片机的步进机电路设计 13. 交通灯控制电路设计 猜你喜欢: 1. 电子信息毕业论文范文 2. 电子信息工程论文范文 3. 电子信息工程发展现状 4. 最新版网络工程专业毕业论文题目 5. 电子信息工程毕业论文范文 6. 电子信息工程论文题目大全

电梯控制系统设计基于西门子PLC的电梯控制系统

火灾报警器论文外文文献

2FSK Signal, Modulation and Modem二进制频移键控信号, 调制和解调Does a communication signal have fingerprint characters? This paper discusses the existence probability of fingerprint characters of communication signals, then analyses fingerprint characters of 2FSK signals,and extracts partial fingerprint characters of 2FSK signals.人有表示个体属性的指纹特征 ,无线电通信信号 (下称信号 )是否存在描述个体电台的电子“指纹”特征 (下称“指纹”特征 )呢 ?文中分析了信号“指纹”特征存在的可能性 ,并以 2FSK信号为例 ,论述了 2FSK信号应具有的“指纹”特征 ,同时提取了其中部分“指纹”特征。According to the characteristics of 2FSK signal and 2PSK signal, a new method based on weak signal detection by Duffing chaotic oscillator to detect 2FSK signal and 2PSK signal is presented.根据Duffing混沌振子微弱信号检测方法进行研究的基础上,根据2FSK信号和2PSK 信 号的特点,提出了一种2FSK、2PSK信号的检测的新方法。To acquire the information of railway binary frequency-shift keying(2FSK)signal s upper and down side frequencies and base low-frequency with high accuracy in real time,a novel frequency detection algorithm compatible with China-made system and France UM71 system was proposed.为实时高精度获取铁道二进制频移键控信号的上、下边频和基带低频信息,提出一种 可兼容国产制式和法国UM71制式的频率检测新方法。The target of the communication system flat is modeling and calculating to modulation and demodulation of seven kinds of signals:AM,FM,SSB,2ASK,2FSK, 2PSK,2QPSK.通信仿真平台的任务是对调幅、调频、单边带、二进制振幅键控、二进制频移键控、二进制相移键控、正交相移键控等七种通信信号的调制和解调进行建模和计算。It emphasizes on 2FSK modem of locking phase loop frequency mixing, hardware and software of addressing control of single-chip computer-AT89C51.介绍了一种基于单片机寻址控制的有线电视收费系统,重点对系统应用锁相频率合成技术的2FSK调制和解调、单片机AT89C51寻址控制的硬件和软件进行了分析,还对系 统利用PIN管宽带工作特点对高频电视信号进行关断和系统的抗干扰措施进行了一定的介绍。 The 308 MHz/315 MHz/418 MHz/433.92 MHz low power FSK Superheterodyne Receiver adopts high integrated,low power,CMOS Superheterodyne RF receiver chips in MAX7042,with a sensibility range from-110 dBm to-109 dBm,receiving a FSK data which speed up to 66 kbps(NRZ)(33 kbps Manchester code). 所设计的308 MHz/315 MHz/418 MHz/433.92 MHz低功耗FSK超外差式接收电路,采用MAX7042高集成度、低功耗,CMOS型超外差式射频(RF)接收芯片,灵敏度为-110~-109 dBm,接收频移键控(FSK)数据速率可达66 kbps(NRZ)(33kbps曼彻斯特编码); Through the experiments with two systems,which based on two kinds of the binary system frequency shift keying(2FSK) modems,the algorithm's validity is tested. 以两种二进制频移键控(binary system frequency shift keying,2FSK)调制 解调器搭建系统进行实验,验证了该方法的有效性。 The working principle,algorithm analysis and software design method of a simplified V.23 2FSK modem based on DSP which is a kind of programmable chip are introduced in this article. 介绍了简易V.23二进制频移键控(2FSK) 调制解调器的工作原理、算法分析以及基于可编程器件DSP的软件设计方法。 The automatic fire alarm system is discussed which consists of a iron-type smoke detector NC14468, a microcontroller 8051 and a radio frequency transceiver nRF401. Because of nRF401 being introduced into which adopts the radio communication technology and the FSK technology , the system is improved increasingly in the performances , such as real-time function and high responsibility. 讨论了用 MC14468 离子型烟雾检测报警器、单片机 8051、nRF401 单片射频收发器构成的火灾自动报警系统。 由于引入了无线通信技术和 FSK(频移键控) 调制解调技术为核心的 nRF401 射频收发器,使系统的性能大大提高,尤其是使系统报警更具实时性和可靠性。 Through the experiments with two systems,which based on two kinds of the binary system frequency shift keying(2FSK) modems,the algorithm's validity is tested. 以两种二进制频移键控(binary system frequency shift keying,2FSK)调制解调器搭建系统进行实验,验证了该方法的有效性。 This dissertation, basing on simulation, makes a deep research on simulating signal of GMSK (Gaussian filtered Minimun Frequency Shift Keying) baseband modulation and demodulation in AIS (Automatic Identification System) equipment. The technology related in the following makes the modulation and demodulation of baseband signal into realization by TI DSP, at the same time, provides a key technique to develop AIS system inland. 着重对自动识别系统(AIS-Automatic Identification System)设备的高斯滤 波最小频移键控(GMSK-Gaussian filtered Minimum Frequency Shift Keying)基带 调制解调信号进行了仿真研究,并在仿真的基础上,在TI的DSP上实现了基带信号的调 制解调,为国内研制AIS系统储备了关键技术。 Moreover,based on the designed fiber grating and the technology of wavelength division multiplexing,a frequency shift keying radio-over-fiber communication system is suggested,and the proposed scheme may be taken as one of the candidates for the next generation high-speed and large-capability radio-over-fiber system. 同时基于所设计的光纤光栅和波分复用技术,提出了一种频移键控光纤无线通信系统Radio Over Fiber系统,为下一代的高速大容量的光纤无线通信系统系统提供一种可行的备选解决方案。 By using the service work that the telecommunication bureau provides caller information to subscriber (inserts caller number and other relevant information between the first and the second ringing of the subscriber terminal) , this scheme sets up a platform using binary frequency shift keying (FSK) decode technique on the subscriber side, receives the caller (reporting side) telephone number, then through the data base in the service equipment, finds the caller (reporting side) material and information, and chooses the corresponding police action plan. 利用电信局对用户提供主叫信息的服务业务 (在对用户终端的第一次和第二次振铃之间 ,插入主叫方号码以及其他有关信息 ) ,在用户终端设置一种采用二进制频移键控 (FSK)解码技术的平台 ,接收主叫 (报警方 )电话号码 ,并通过服务器里 的数据库 ,查询到主叫(报警方 )的资料 ,然后做出相应的处警方案评价 添加词条 短句来源 For the conventional modulation and demodulation of Minimum Frequency Shift Keying(MSK), the new models for modu-lation and demodulation on digital MSK based on VHDL are developed. 针对传统的最小频移键控(MSK) 的调制解调方式,提出一种基于甚高速硬件描 述语言(VHDL)的数字式MSK调制解调模型。 The conception,classification,research status and system structure are presented in this paper,also it presents a new space-time coded cooperation based on space-time frequency keying,and finally analyzes its performance. 介绍了协作分集技术的基本概念、分类、研究现状以及系统结构,提出了由空时频移键控设计的空时编码协作分集方式,并分析了其性能。 Combining the advantages of space-time block codes and frequency keying, space-time frequency keying (ST-FSK), which did not require any channel state information at the transmitter and the receiver, could adopt the non-coherent ML detector under the Rayleigh fading channels [1]. 空时频移键控(ST- FSK)结合了空时分组码和频移键控的优点,在瑞利衰落信道条件下无需信道信息,可采用非相干的最大以然(ML)检测器。 In the scheme, FSK-FDM technique is used in sub-carrier modulation, and the EDFA’s supervisory information is transmitted by optical intensity modulation. 该方案利用频移键控 频分复用 (FSK FDM)技术进行声频副载波调制 ,通过光强度调制实现远程在线EDFA监控信息随主信号的传输。 There are three basic types of digitally modulated signal: MASK, MPSK and MFSK. 数字调制信号分三种基本类型:多进制幅度键控MASK、多进制相移键控MPSK和多进制频移键控MFSK。 For improving the baud rate of system, this text adopts the GMSK (Gauss in Filtered Minimum Shift Keying) modulation method to replace ASK (Amplitude Shift Keying) modulation method of current IFCNSS. 为提高系统的传输速率,本文采用GMSK(Gaussian Filtered Minimum Shift Keying高斯滤波最小频移键控)调制方式来代替目前“安全通信网”中的ASK(Amplitude Shift Keying幅移键控)调制方式。

An automatic fire alarm system is designed to detect the unwanted presence of fire by monitoring environmental changes associated with combustion. In general, a fire alarm system is either classified as automatically actuated, manually actuated, or both. Automatic fire alarm systems can be used to notify people to evacuate in the event of a fire or other emergency, to summon emergency services, and to prepare the structure and associated systems to control the spread of fire and smoke. Design After the fire protection goals are established - usually by referencing the minimum levels of protection mandated by the appropriate model building code, insurance agencies, and other authorities - the fire alarm designer undertakes to detail specific components, arrangements, and interfaces necessary to accomplish these goals. Equipment specifically manufactured for these purposes are selected and standardized installation methods are anticipated during the design. In the United States, NFPA 72, The National Fire Alarm Code is an established and widely used installation standard.[edit] Fundamental configuration A Honeywell fire alarm control panel. Fire alarm control panel: This component, the hub of the system, monitors inputs and system integrity, controls outputs and relays information. Primary Power supply: Commonly the non-switched 120 or 240 Volt Alternating Current source supplied from a commercial power utility. In non-residential applications, a branch circuit is dedicated to the fire alarm system and its constituents. "Dedicated branch circuits" should not be confused with "Individual branch circuits" which supply energy to a single appliance. Secondary (backup) Power supplies: This component, commonly consisting of sealed lead-acid storage batteries or other emergency sources including generators, is used to supply energy in the event of a primary power failure. Initiating Devices: This component acts as an input to the fire alarm control unit and are either manually or automatically actuated. Notification appliances: This component uses energy supplied from the fire alarm system or other stored energy source, to inform the proximate persons of the need to take action, usually to evacuate. Building Safety Interfaces: This interface allows the fire alarm system to control aspects of the built environment and to prepare the building for fire and to control the spread of smoke fumes and fire by influencing air movement, lighting, process control, human transport and exit. [edit] Initiating devices Manually actuated devices; Break glass stations, Buttons and manual pull station are constructed to be readily located (near the exits), identified, and operated. Automatically actuated devices can take many forms intended to respond to any number of detectable physical changes associated with fire: convected thermal energy; heat detector, products of combustion; smoke detector, radiant energy; flame detector, combustion gasses; carbon monoxide detector and release of extinguishing agents; water-flow detector. The newest innovations can use cameras and computer algorithms to analyze the visible effects of fire and movement in applications inappropriate for or hostile to other detection methods. [edit] Notification appliances Main article: Fire alarm notification appliance A Honeywell speaker and a Space Age Electronics V33 remote light. Audible, visible, tactile, textual or even olfactory stimuli (odorizer).[1] to alert the occupants. Audible or visible signals are the most common and may utilize speakers to deliver live or pre-recorded instructions to the occupants. In the United States, fire alarm evacuation signals are required to use a standardized interrupted four count temporal pattern to avoid confusion with other signals using similar sounding appliances. Other methods include: Audible textual appliances, which are employed as part of a fire alarm system that includes Emergency Voice Alarm Communications (EVAC) capabilities. High reliability speakers are used to notify the occupants of the need for action in connection with a fire or other emergency. These speakers are employed in large facilities where general undirected evacuation is considered impracticable or undesirable. The signals from the speakers are used to direct the occupant's response. The system may be controlled from one or more locations within the building known as Fire Wardens Stations, or from a single location designated as the building Fire Command Center. Speakers are automatically actuated by the fire alarm system in a fire event, and following a pre-alert tone, selected groups of speakers may transmit one or more prerecorded messages directing the occupants to safety. These messages may be repeated in one or more languages. Trained personnel activating and speaking into a dedicated microphone can suppress the replay of automated messages in order to initiate or relay real time voice instructions.[2] [edit] Building safety interfaces S.H. Couch F5GX non-coded fire alarm pull station below a Couch 10" bell. Magnetic Smoke Door Holders: Wall or floor mounted solenoids or electromagnets controlled by a fire alarm system or detection component that magnetically secures spring-loaded self-closing smoke tight doors in the open position. Designed to de-magnetize to allow automatic closure of the door on command from the fire control or upon failure of the power source, interconnection or controlling element. Stored energy in the form of a spring or gravity can then close the door to restrict the passage of smoke from one space to another in an effort to maintain a tenable atmosphere on either side of the door during evacuation and fire fighting efforts. Duct Mounted Smoke Detection: Smoke detection mounted in such a manner as to sample the airflow through duct work and other plenums specifically fabricated for the transport of environmental air into conditioned spaces. Interconnection to the fan motor control circuits are intended to stop air movement, close dampers and generally prevent the recirculation of toxic smoke and fumes produced by fire into occupiable spaces. [edit] UK fire alarm system categories There are many types of fire alarm systems each suited to different building types and applications. A fire alarm system can vary dramatically in both price and complexity, from a single panel with a detector and sounder in a small commercial property to an addressable fire alarm system in a multi-occupancy building. Systems have to protect both buildings and occupants.The categories of fire alarm systems are L if they are designed to protect life, P to protect buildings and M if they are manual systems.[3]MManual systems, e.g. hand bells, gongs, etc. These may be purely manual or manual electric, the latter may have call points and sounders. They rely on the occupants of the building discovering the fire and acting to warn others by operating the system. Such systems form the basic requirement for places of employment with no sleeping risk.P1The system is installed throughout the building - the objective being to call the fire brigade as early as possible to ensure that any damage caused by fire is minimized. Small low risk areas can be excepted, such as toilets and cupboards less than 1m�0�5.P2Detection should be provided in parts of the building where the risk of ignition is high and/or the contents are particularly valuable. Category 2 systems provide fire detection in specified parts of the building where there is either high risk or where business disruption must be minimised.L1A category L1 system is designed for the protection of life and which has automatic detectors installed throughout all areas of the building (including roof spaces and voids) with the aim of providing the earliest possible warning. A category L1 system is likely to be appropriate for the majority of residential care premises. In practice, detectors should be placed in nearly all spaces and voids. With category 1 systems, the whole of a building is covered apart from minor exceptions.L2A category L2 system designed for the protection of life and which has automatic detectors installed in escape routes, rooms adjoining escape routes and high hazard rooms. In a medium sized premises (sleeping no more than ten residents), a category L2 system is ideal. These fire alarm systems are identical to an L3 system but with additional detection in an area where there is a high chance of ignition, e.g., kitchen) or where the risk to people is particularly increased (e.g., sleeping risk).L3This category is designed to give early warning to everyone. Detectors should be placed in all escape routes and all rooms that open onto escape routes. Category 3 systems provide more extensive cover than category 4. The objective is to warn the occupants of the building early enough to ensure that all are able to exit the building before escape routes become impassable.L4Category 4 systems cover escape routes and circulation areas only. Therefore, detectors will be placed in escape routes, although this may not be suitable depending on the risk assessment or if the size and complexity of a building is increased. Detectors might be sited in other areas of the building, but the objective is to protect the escape route.L5This is the "all other situations" category, e.g., computer rooms, which may be protected with an extinguishing system triggered by automatic detection. Category 5 systems are the "custom" category and relate to some special requirement that cannot be covered by any other category.

Fire FightingAlong with the our country economic development rapid development, the lives of the people level unceasing enhancement, the city uses to be day by day anxious, urges the building to face the direction is developing. This kind of high level civil construction repair needed materials and the way also more hasten the diversification, and along with uses electricity the load and coal gas consumption quantity enlarging, proposed to the fire auto-alarm system design is higher, a stricter request. In order to guarantee the people life and property the security, the fire auto-alarm system design has become in the high level civil construction design one of most important design contents. Presently based on the author fire of auto-alarm system design overseeing work in the high level civil building experience, proposed in present national related standard and standard unclear true detail shallow opinion, by for the colleagues to discuss and to point out mistakes.First, design basis The fire auto-alarm system design is a specialized very strong technology work, at the same time also has the very strong policy-type. Therefore, first should be clear about the following design basis: 1st, must grasp the architectural design fire protection standard, the system design standard, the equipment manufacture standard, the installment construction approval standard and the administration laws and regulations and so on five big aspects fire laws and regulations, and in practical understanding present country related standard and standard positive word: "Must", "be supposed", "to be suitable", "may" and the reverse side word: "Strictly prohibits", "should not", "not have", "not to be suitable" the meaning.2nd, must aim at high level civil building function, use and the protection object fire protection rank, earnestly carries out the present national related standard and the standard, earnestly treats the public security fire prevention surveillance department the examination and approval opinion.Second, fire auto-alarm system equipment establishmentFire detector establishmentOpens wide either the seal or the stair hall should alone divide the search coverage, and each 2 ~ 3 establish a fire detector.The first room (including guards against in front of smoke stair hall in front of room, fire elevator room, fire elevator with guards against the front room which smoke stair hall comes in handy) and the aisle should distinguish alone to divide the search coverage, specially front the room and the lift well, the scattered stair hall and the aisle are interlinked, has time the fire haze to be easier to gather or to flow, is the personnel disperses which saves goal with the fire prevention, therefore should install the fire detector. Regarding common elevator in front of room although is not the personnel disperses , but this front room and the lift well are interlinked, has time the fire haze to be also easy to gather or to flow, suitably alone divides the search coverage and installs the fire detector. The electric cable shaft therefore is easy to form pulls out the smoke inflammation the channel; Has when the fire the fire intensity not easily extends along the electric cable burns, for this, "the high level civil construction design fire protection standard" and "the civil construction electricity design standard" separately proposes the detailed specific stipulation in the construction and in the electric wire or on the electric cable shaping. But considered implements specifically the difficulty and the present situation, the electric cable shaft installs the fire detector is extremely essential, and coordinates the shaft the fire protection separation request, each 2 ~ 3 or each level installs.The elevator machine room should install the fire detector, its elevator is the important vertical transportation vehicle; Its two elevator machine room has has the fire risk; Its three lift well existence essential opens the hole, like the level gate opens between the hole, the air vent, the between permanence opens the hole with the elevator machine room or the pulley and so on; Its four when has the fire, the lift well often becomes the fire intensity spread the channel, is easy to threaten the elevator machine room the facility. Therefore, the elevator machine room establishes the fire detector is necessary, crown of also suitable establishment fire detector lift well.2nd, the manual fire reports to the police the button establishment(Including guards against in front of smoke stair hall in view of various floors front room in front of room, fire elevator room, fire elevator with guards against which smoke stair hall to come in handy the front room) is has when the fire the personnel to disperse which saves goal with fire prevention, should report to the police the button first choice spot as the establishment manual fire. In addition, the room also should establish the manual fire to the common elevator in front of to report to the police the button.In the public active place (including hall, hall, dining room, multi-purpose hall and so on) and the main thoroughfare and so on place, the personnel very is all centralized, and mainly disperses the channel. Therefore should report to the police the button in these public active places main access establishment manual fires; The manual fire establishes which in the main thoroughfare reports to the police the button to guarantee "to a manual fire which most is close to reports to the police the button distance from a fire protection district any position not to be supposed to be bigger than 30 meters".3rd, the fire emergency broadcasts the speaker the establishmentThe aisle, the hall, the dining room and so on the public place personnel very are all centralized, and mainly disperses the channel. Therefore should press in these public places "to a recent speaker distance is not bigger than 25 meters from a fire protection district any spot" and "in the aisle last should not be bigger than 12.5 meters the speaker to the aisle terminal distance" the establishment fire emergency to broadcast the speaker; Next also should establish the fire in the public bathroom place emergency to broadcast the speaker.The first room (including guards against in front of smoke stair hall in front of room, fire elevator room, fire elevator with guards against which smoke stair hall to come in handy the front room) is has when the fire the personnel to disperse which saves goal with fire prevention, also has the fire door separation and the sounds of people is confused and noisy, therefore should establish the fire emergency to broadcast the speaker. In front of the common elevator the room also should establish the fire emergency to broadcast the speaker. Disperses the stair hall also is has when the fire the personnel to disperse which saves goal with the fire prevention, also the sounds of people are confused and noisy, therefore should establish the fire emergency to broadcast the speaker, by favors the fire emergency broadcast to disperse the instruction.4th, fire alarm installment establishmentThe establishment fire emergency broadcast fire auto-alarm system, the author thought also should install the fire alarm installment, but its control procedure should be: The alarm apparatus should confirm after the fire, uses manual or the automatic control mode unification to the fire correlation region transmission warning, stops the alarm apparatus work in the stipulation time, the rapid linkage fire emergency broadcast and broadcasts to the people disperses the instruction.The fire alarm installment establishment position, the author thought should report to the police the button position with the manual fire to be same, its wall surface installment should for be apart from the ground 1.8 meters highly5th, fire special use telephone establishmentInstalls the fire special use telephone extension telephone, should be located the engine room which related also some people is on duty frequently with the fire linkage control (including fire water plant, spare electricity generation engine room, matches substation, mainly ventilates with air conditioning engine room, discharges fume engine room, fire prevention elevator machine room and other), the fire fighting control system operates the equipment place or the control room, the fire duty officers observation room, the security manages spot and so on public room. Sedan of theater box the fire elevator and in the ordinary elevator all should suppose the special use telephone, requests the elevator machine room and the elevator sedan theater box, the elevator machine room and the fire control room, the elevator sedan theater box and the fire control room and so on three compositions is reliable to speaks the correspondence telephone system. Usually in fire control room; The establishment elevator monitoring demonstration plate (including position indicator, direction indicating lamp, to speaks correspondence telephone, trouble lamp and so on), in order to carries on the necessity to the elevator running status which in the surveillance and the emergency case controls.Is equipped with the manual fire to report to the police position and so on button, fire hydrant button also should install the fire special use telephone receptacle.Third, fire linkage control 1st, the fire linkage control should include the control fire pump to open, to stop, also should demonstrate opens pumps the button the position and the fire pump work and the malfunction. When the fire hydrant is equipped with the fire hydrant button, its electric installation work spot also should demonstrate the fire pump the working mode active status (namely establishment fire pump work indicating lamp). 2nd, the fire linkage control should include the control spraying of water and the water atomization fire fighting system opens, stops, also should demonstrate the fire pump the work and the malfunction and the fluent display, reports to the police the valve, the safety signal valve working mode active status. In addition, to the basin, the water tank water level also should carry on the demonstration monitor; In order to prevent the overhaul signal valve is shut down, the author thought should use the belt electric signal the control signal valve by to demonstrate it opens the condition. 3rd, the fire linkage control other controls and the demonstration function, should carry out the present national related standard and the standard specific stipulation.Fourth, fire auto-alarm system wiringIn order to prevent the fire occurs when the fire control, the correspondence and the warning line severance, causes the fire fighting work to be unable to carry on, creates the bigger economic loss; Also for the suppression electronmagetic interference (for example transformer, electric motor, electric cable and so on) the influence which produces to the fire auto-alarm system. The fire auto-alarm system transmission line and the fire control, the correspondence and the warning line should use the being flame-resistant electric cable, and should use the metal tube or the enclosed metal trunking protection. The fire manual positive governing installment line should use the fireproof electric cable, its electric cable also should use the metal tube or the enclosed metal trunking protection. Uses Ming Fushi, should takes the fire protection protective measures on the metal tube or the enclosed metal trunking.Fifth, concluding remarkThe author rests on the concrete project to implement the experience, elaborated the design basis, fire auto-alarm design actual problem and so on system equipment establishment, fire linkage control and its wiring pulls out some shallow opinions, its goal is enhances the fire auto-alarm system the design quality, discovered early and the notification fire, prevented and reduces the fire to harm, by protects the person and the property safety.消防 随着我国经济发展快速发展,人民生活的水平不断提高,城市使用是每天着急,敦促建设面临着发展的方向。这种高层次的民间建筑维修所需的材料和方式也更加多样化加快,而且随着使用电力负荷和煤气消费量扩大,提议消防自动报警系统设计较高,更严格的要求。为了保证人民生命和财产的安全,消防自动报警系统的设计已经成为在高级别民间建筑设计的一个最重要的设计内容。目前的基础上撰文火灾自动报警系统设计监督工作的高层次的民间建设的经验,建议在目前国家相关标准和标准不清楚真正详细浅见解,为同事们的讨论,并指出错误。 首先,设计依据 火灾自动报警系统的设计是一家专业非常强的技术工作,同时还具有很强的政策性。因此,首先应明确以下设计依据: 第一,必须紧紧抓住的建筑设计防火标准,该系统的设计标准,标准的设备制造,安装施工审批标准和管理的法律和规章等五大方面的消防法律法规,并在实际了解国家有关本标准和标准积极字: “必须” , “必须假定” , “不适合” , “可能”和反面词: “严格禁止” , “不应该” , “没有” , “不适合“的含义。 第二,必须着眼于高层次的民间建筑的功能,利用和保护对象的防火等级,认真开展本标准和国家有关标准,认真对待公安防火监督部门的审批意见。 其次,火灾自动报警系统设备的建立 建立火灾探测器 要么全打开的印章或楼梯大厅应单独划分搜索范围,每个2 〜 3建立火灾探测器。 第一个房间(包括防前面的烟雾大厅楼梯前室,消防电梯间,消防电梯防前面房间烟雾楼梯大会堂来用场)和过道应区分单独划分搜索范围,特别是前面的房间,以及电梯,分散楼梯大厅和走道都是相互关联的,有时间的火灾烟雾比较容易收集或流动,是人员分散保存目标与防火,因此,应该安装火警探测器。关于共同电梯前室虽然不是人员分散,而且这方面的空间和良好的电梯是相互关联的,有时间的火灾烟雾也很容易被收集或流动,适当地划分为单独的搜索覆盖面和安装消防探测器。 电缆轴因此很容易形成掏出烟炎症渠道,拥有火灾时的火强度不容易延伸沿电缆燃烧,为此, “高级别民间建筑设计防火标准”和“民用建筑电气设计标准“分别提出了详细具体的规定,在建筑和在电线或电缆塑造。但认为具体实施的难度和目前的情况下,电缆竖井安装了火灾探测器是非常必要的,坐标轴的防火分隔要求,每2 〜 3或每一级安装。 电梯机房应安装火灾探测器,它的电梯是重要的垂直交通工具,其两个电梯机房已具有火灾危险性,其存在的三个基本解除以及打开洞,像打开闸门的水平之间的球洞,在气孔,持久的关系打开了洞与电梯机房或滑轮等,其时,有四个火,升降机以及往往成为火灾强度传播渠道,很容易危及电梯机房设施。因此,电梯机房建立了火灾探测器是必要的,也适用于皇冠建立火灾探测器举井。 2 ,手动火警报警按钮建立 (包括防前面的烟雾楼梯大厅鉴于各层前房间前面的房间,消防电梯间,消防电梯防这些烟雾楼梯大会堂派上用场前室)是有火灾时人员驱散节省目标,防火,应立即向警方举报的按钮,首选地点设立手动火警。此外,该室也应建立防火手册的共同电梯前,向警方报案的按钮。 在公共活动场所(包括会堂,礼堂,餐厅,多功能厅等)和主要通道等场所,是所有工作人员非常集中,主要是分散的渠道。因此,应立即向警方举报的按钮,在这些公共活动场所主要通道设立手册火灾;该手册规定的火灾中的主要通道报警按钮,以保证“ ,以手动火警最接近报警按钮距离防火区的任何位置不应该超过30米。 “ 第三,消防紧急广播喇叭建立 走道,大厅,餐厅等公共场所的工作人员都非常集中,主要是分散的渠道。因此,应该按这些公共场所的“最近的一项发言距离不超过25米的防火保护区的任何位置”和“在走道上不应大于十二点五米扬声器的过道末端距离”建立消防应急广播喇叭;下一步还应当建立消防在公共浴室的地方紧急广播喇叭。 第一个房间(包括防前面的烟雾大厅楼梯前室,消防电梯间,消防电梯防这些烟雾楼梯大会堂派上用场前室)是有火灾时的人员驱散节省目标与防火,也有分离和防火门的声音,人民的混乱和嘈杂,因此,应建立消防应急广播喇叭。在前面的共同电梯房也应建立消防应急广播喇叭。分散大厅楼梯也已经火灾时的人员驱散节省目标与防火,也是人民的声音和嘈杂的混淆,因此应建立消防应急广播喇叭,由主张消防紧急广播驱散指令。 第四,建立火灾报警装置 建立消防应急广播火灾自动报警系统,笔者认为还应该安装消防报警装置,但它的控制程序应该是:该报警器应确认火灾后,利用手动或自动控制模式统一消防相关区域传输预警,报警器停止工作时间的规定,迅速联系消防应急广播和电视节目,并且分散了人们的指示。 火警警报装置建立的立场,笔者认为应该向警方报案的按钮位置的手动火警是相同的,它的墙面安装应为距地面1.8米高度 第五,消防专用电话设立 安装消防专用电话分机电话,应设机房其中也涉及一些人是在工作地点经常与消防联动控制(包括消防给水设备,备件发电机房,火柴变电站,主要ventilates空调引擎室,排放烟气轮机室,防火电梯机房及其他) ,消防控制系统的经营场所或设备的控制室,消防责任人员观察室,现场的安全管理等公共空间。轿车的影院中消防电梯和普通电梯应假设所有使用的特殊电话,请电梯机房和电梯轿车影院中,电梯机房及消防控制室,电梯轿车影院方块和消防控制室等三个成分是可靠的讲通信电话系统。通常在消防控制室;建立电梯监测演示板(包括位置指示器,显示方向灯,以讲信函电话,麻烦灯等) ,以进行必要的电梯在运行状态的监视和紧急情况下的控制。 配备了手动火警报警位置等按钮,消火栓按钮,还应该安装消防专用电话插座。 第三,消防联动控制 第一,消防联动控制应包括控制消防泵开启,停止,也应表现出的按钮,打开泵的位置和消防泵的工作和故障。当消火栓设有消火栓按钮时,其电气安装工程现场也应表现出的消防泵的工作模式有效状态(即建立消防泵工作表明灯) 。 第二,消防联动控制应包括控制喷洒水和水雾化灭火系统打开,停止,也应表现出的消防泵的工作和故障和流利显示,报警阀,安全信号阀工作模式积极的地位。此外,该盆地,水箱水位也应进行示范监测;为了防止检修信号阀关闭,作者认为应该使用带电信号控制信号阀证明它打开条件。 第三,消防联动控制其他控制和示范作用,应进行本标准和国家有关标准的具体规定。 第四,火灾自动报警系统布线 为了防止火灾发生时,消防控制,通信和警戒线遣散,使灭火工作无法进行,造成了更大的经济损失,也为抑制electronmagetic干扰(例如变压器,电电机,电缆等)的影响而产生的火灾自动报警系统。火灾自动报警系统的输电线路和消防控制,通信和预警线应使用被阻燃电缆,并应使用金属管或封闭式金属线槽保护。消防手册积极理事分期付款行应使用防火电缆,其电缆也应使用金属管或封闭式金属线槽保护。使用明复,应采取防火保护措施的金属管或封闭金属trunking.Fifth ,结论备注 作者取决于具体的项目实施经验,阐述了设计依据,火灾自动报警设计和实际问题,以便建立系统设备,消防联动控制及其接线拿出一些肤浅的意见,其目的是增强了火灾自动报警系统的设计质量,早期发现,并通知消防,预防和减少火灾危害,通过保护个人和财产安全。 -----------希望可以符合要求--

多传感器火灾报警器毕业论文

相关范文:智能无线防盗系统的设计摘要:系统地介绍智能无线防盗系统的基本原理、组成框图,详细地描述电话网络的接收方法;论述热释电红外传感器、语音等电路,给出部分基本电路和软件流程。关键词:无线防盗 报警 热释电红外传感器随着国家智能化小区建设的推广,防盗系统已成为智能小区的必需设备。本文利用单片机控制技术和无线网络技术,开发一种具有联网功能的智能无线防盗系统,并开发相关的传感器。采用无线数据传输方式,不需重新布线,特别适用于已装修用户及布线不方便的场合。1 智能无线防盗系统的基本原理智能无线防盗系统由传感器、家庭智能报警器、物业管理中心接警主机及相关的控制管理软件组成。图1为家庭智能报警器方框图,图2为物业管理中心接警主机方框图。1.1 主机电路如图1所示,主机电路由射频接收模块接收传大吃一惊器发来的报警信号,通过解码器(PT2272)解码后得到报警传感器的地址和数据类型只有主机和传感器地址相同时才能被主机接收。解码输出的数字代表传感器类型解骊输出信号进入CPU的INT1,触发中断处理程序。中断处理程序通过DTMF收发电路,拨打用户预先设好的电话号码(如手机号码,办公室号码)进行远程拨号报警;同时,启动语音电路,将预先录制好的语音信号通过电话线传给主人,实现语音提示通信功能。CPU输出警笛触发信号,经放大后推动警笛或喇叭,以驱赶和震胁盗贼。用户还可通过电话线进行远程设/布防,及输入远程控制信号,通过8路控制输出端控制有线连接的电器设备,也可通过编码电路和射频发射模块控制无线连接的电器设备。显示部分采用RT12232A图形点阵LCD模块,实现汉字显示功能;显示报警时间与报警类型。键盘可实现密码修改、语音录入和信息查看功能。物业管理中心的接收主机具有家庭报警主机的功能外,还可以通过RS232实现与物业管理中心的通信 功能,实现联网和小区控制。1.1.1 DTMF收发电路要实现电话线远程通信,关键部分为DTMF收发电路。它将实现自动拨号、忙音识别、铃声识别、远程接键数字信号识别等功能。我们选用MT8888双音多频(DTMF)收发器,与单片机及音频放大电路组合,实现各种信号音的检测及DTMF信号的产生,并将DTMF信号送到电话线上,如图3所示。MT8888是采用CMOS工艺生产的DTMF信号收发一体的集成电路。它的发送部分采用信号失真小、频率稳定性高的开关电容式D/A变换器,可发出16种双音多频DTMF信号。接收部分用于完成DTMF信号的妆收、分离和译码,并以4位并行二进制码的方式输出。图3选择中断模式时,当接收或发送了有效的音频信号后IRQ/CP脚输出低电平,产生中断信号供给CPU,在延迟控制电压的跳变缘将数据锁存至输出端;当选择呼叫过程(CP)方式时,只能接收250~550Hz的信号音,在拒收或无输入时,IRQ/CP脚输出低电平。(1)电话信号音格式忙音:450Hz,350ms有,350ms无。拨号音:450Hz,持续。回铃音:450Hz,1s有,4s无。(2)信号音的判断方式将MT8888的IRQ/CP脚连到AT89S52的T0脚,电话呼叫过程中的各种信号音经MT8888滤波限幅后得到方波,由MT8888的IRQ输出到AT89S52的T0脚,对T0脚信号记数5s。计数值位于2175~2357范围内,为拨号音;计数值位于1041~1212范围内,为忙音;计数值位于425~475范围内,为回铃音。在实际编程中,考虑到计数的误差以及程序的简化,可将范围适当放宽,但不能重叠。(3)自动摘机控制器与家里电话并接在一条电话线上。为了实现报警放打电话共用一条线,摘机电路按如下设置:将电话振铃信号通过光电耦合器TP521输入到AT89S52的IT脚,进行计数。接到振铃信号时,若连续振铃10次用户还没有摘机,则自动转到家庭智能报警器,CPU置P1.5脚为“1”,使继电器K1吸合,实现自动摘机功能。若在这10次振铃过程中,用户接通了电话,则控制器不响应,这样,使得控制器与电话不互相干扰。摘机后,检测MT8888输出的双音多频信号,以读出用户发来的远程信息,实现远程通信与控制功能。图4(4)自动报警当接收到热释电传感器等发来的无线报警信号后,CPU立即发出报警信号,通过电话线传到远程用户。报警方式如下:用户通过面板设备10个报警电话,将它们存入24C04存储器中。当接到警情后,从第1个电话开始拨号,一直拨到第10个,来回拨3遍。如果任意一个电话回送了“#”键确认信号,即意味着报警已收到,不再继续拨号。每个号码需拨号。每个号码需拨号时间100ms,号码之间留500ms间隔。拨号时,先检测24C04中存储的电话号码。若为空,即未设此电话,跳过不拨,继续拨下一个电话号码。这样,用户可随意设置数个报警电话号码。我们规定号码长度最多不超过4位,以便存在24C04中。1.1.2 语音电路为了便于通信,采用了语音芯片,实现语音指示和报警功能。ISD1420为单片语音记录、回放一体化芯片,记录时长为20s;可被划分为160小段,每段125ms。当REC脚为低电平时,进行录音,PLAYE或PLAYL为低时进行放音,ISD1420可进行连续录音,也可进行分段录音。分段放音:先送停止录放音码P1.2~P1.4=000,再送放音首地址A7~A0,P1.3或P1.4为低电平(PLAYE或PLAYL)开始放音;延时进行放音,最后送停止录放音码P1.2~P1.4=000,完成本段放音。重复上述过程,可分段放出数段语音。图4为语音电路原理。1.1.3 编/解码电路PT2262/2272是台湾普城公司生产的一种CMOS工艺制造的低功耗、低价位、通用编解码电路。PT2262/2272最多可有12位(A0~A11)三态地址端引脚(悬空、接高电平、接低电平),任意组合可提供531441地址码。PT2262最多可有6位(D0~D5)数据端引脚,设定的地址码和数据码从17脚串行输出。编码芯片PT2262发出的编码信号由地址码、数据码、同步码组成一个完整的码字。地址码必须与家庭控制主机内解码芯片PT2272编址相同,以区分家庭控制器;数据码可用于区分传感器类型。当有报警信号时,PT2262的14脚为低电平,使能PT2262,从17脚输出编码信号,通过射频模块发射出去。解码芯片PT2272接收到信号后,其地址码经过两次比较核对,VT脚才输出高电平,送到89S52的INT1,触发中断处理程序,以读取D0~D3的数据码,得知报警传感器状态和报警类型。图5为编/解码电路原理。1.1.4 射频发射模块与射频接收模块射频发射模块与射频接收模块原理如图6和图7所示,工作频率为433MHz。最大传输距离可达1000m。1.2 传感器设计1.2.1 被动红外热释电传感器人体有恒定的体温,一般在37℃,所以会发出特定波长为10μm左右的红外线。被动式红外探头就是靠探测人体发射的10μm左右的红外线而进行工作的。人体发射的10μm左右的红外线,通过菲涅尔滤光片增强后,聚集到红外感应源上。红外感应源泉通常采用热释电元件。这种元件在接收到人体红外辐射温度发生变化时将会失去电荷平衡,向外释放电荷,后续电路经检测处理后产生报警信号。图8为双元热释电红外检测元件LHI968的内部电路。它由两个双元热释电陶瓷,感应红外信号,再经场效应管放大输出。D端的电阻和S端的电容具有抗电磁干扰能力。图7信号从S端引出经前级放大,通过47μF电容后再次放大,与设定门限电压进行比较,获得报警输出信号。47μF电容能够除直流成分,从而消除了使用环境(阳光、灯光、火源泉等)对探测器的影响,后面再加一延时触发电路以便主人设防与撤防。现在已有专用集成芯片BISS0001实现以上功能。为了适应主人进门时撤防的需要,设计一报警延时电路。延时长度须满足:当人以1m/s的速度从探测器的正前方移动0.2m,不产生报警;但移动3m应报警,测试速度应能检测0.3~3m/s或更宽的速度范围。1.2.2 门磁传大吃一惊器无线门磁传感器一般案卷在门内侧的上方。它由两部分组成:较小的部件为永磁体,内部有一块永久磁铁,用来产生恒定的磁场;较大的是无线门磁主体,内部有一个常开型的干簧管。当永磁体和干簧管靠得很近时(小于5mm),无线门磁传感器处于工作守候状态;当永磁体离开干簧管一定距离后,无线门磁传感器立即发射包含地址编码和自身识别码(也就是数据码)的433MHz的高频无线电信号。主机通过识别这个无线电信号的地址码,判断是否为同一个报警系统,然后根据自身识别码(也就是数据码),确定是哪一个无线门磁报警。2 网络中心控制主机设计网络中心控制主机设计与家庭控制器基本相同,只是加了一个RS232接口,实现与PC机相连。通过放在物管中心的PC机实现小区网络监控功能。结语采用现有电话网络,结合射频无线通信技术和单片机网络控制技术,使本防盗报警系统经济、可靠,组网灵活;家庭无需为传感器布线;具有广泛的市场发展前景。其他相关:仅供参考,请自借鉴希望对您有帮助

多传感器火灾报警系统设计(论文+程序+答辩ppt) 摘要:本文首先介绍了火灾报警系统的发展情况;然后,详细介绍了系统硬件、软件的设计;并且对硬件进行了简单的调试,最后,文章对整个设计做了概括性总结。硬件设计是本文一个重点,包括系统总体结构以及火灾探测器结构及功能设计,其中详细论述了火灾探测器主控板的设计。主控板主要完成采集传感器数据、实现火灾探测器的数据交换等功能。硬件设计的最后部分,还论述了如何提高系统抗干扰能力,提高系统可靠性。软件设计包括数据采集程序,火灾报警程序等的设计,完成了火灾传感器软件的功能设计并给出了程序流程图。最后的仿真结果表明,该设计能够有效解决灵敏度与误报率之间的矛盾,基本达到了预期的效果。本系统具有智能化和高可靠性等特点,但是还是有一些环节有待进一步完善.关键词:多传感器,火灾报警,高可靠性。目 录第1章 绪论 11.1 火灾报警技术的发展概况 11.2 现代消防管理对火灾报警系统的需求 21.3 国内外火灾报警控制系统的研究概况 31.4 课题主要工作及内容安排 41.5 课题研究的意义 5第2章 方案设计 62.1 传感器方案的选择 62.2 系统主要功能 72.3 系统结构及工作流程 72.4 小结 8第3章 火灾报警系统控制模块设计 93.1 单片机的选择 93.2 传感器选型 113.3 传感器信息采集电路设计 153.4 声光报警电路设计 183.5 电源模块/稳压电源 203.6 时钟电路 223.7 看门狗的使用 233.8 通信的设计 253.9 小结 26第4章 报警系统的软件设计 274.1 火灾报警系统软件的要求 274.2 火灾探测系统软件设计 274.2.1 传感器信息采集模块的软件设计 294.2.2 声光报警的软件设计 304.2.3 时钟电路的软件设计 314.2.4 通信系统软件设计 334.3 小结 34第5章 系统调试 355.1 处理器测试 355.2 声光报警电路调试 355.3 通信串口调试 365.4 A/D转换电路调试 375.5小结 37结 论 38参 考 文 献 40附 录 41附录1 系统硬件接线图 41附录2 系统的PCB图 42附录3 硬件实物图 43附录4 部分程序一览 44

智能无线防盗系统的设计 摘要:系统地介绍智能无线防盗系统的基本原理、组成框图,详细地描述电话网络的接收方法;论述热释电红外传感器、语音等电路,给出部分基本电路和软件流程。 关键词:无线防盗 报警 热释电红外传感器 随着国家智能化小区建设的推广,防盗系统已成为智能小区的必需设备。本文利用单片机控制技术和无线网络技术,开发一种具有联网功能的智能无线防盗系统,并开发相关的传感器。采用无线数据传输方式,不需重新布线,特别适用于已装修用户及布线不方便的场合。 1 智能无线防盗系统的基本原理 智能无线防盗系统由传感器、家庭智能报警器、物业管理中心接警主机及相关的控制管理软件组成。图1为家庭智能报警器方框图,图2为物业管理中心接警主机方框图。 1.1 主机电路 如图1所示,主机电路由射频接收模块接收传大吃一惊器发来的报警信号,通过解码器(PT2272)解码后得到报警传感器的地址和数据类型只有主机和传感器地址相同时才能被主机接收。解码输出的数字代表传感器类型解骊输出信号进入CPU的INT1,触发中断处理程序。中断处理程序通过DTMF收发电路,拨打用户预先设好的电话号码(如手机号码,办公室号码)进行远程拨号报警;同时,启动语音电路,将预先录制好的语音信号通过电话线传给主人,实现语音提示通信功能。CPU输出警笛触发信号,经放大后推动警笛或喇叭,以驱赶和震胁盗贼。用户还可通过电话线进行远程设/布防,及输入远程控制信号,通过8路控制输出端控制有线连接的电器设备,也可通过编码电路和射频发射模块控制无线连接的电器设备。显示部分采用RT12232A图形点阵LCD模块,实现汉字显示功能;显示报警时间与报警类型。键盘可实现密码修改、语音录入和信息查看功能。 物业管理中心的接收主机具有家庭报警主机的功能外,还可以通过RS232实现与物业管理中心的通信 功能,实现联网和小区控制。 1.1.1 DTMF收发电路 要实现电话线远程通信,关键部分为DTMF收发电路。它将实现自动拨号、忙音识别、铃声识别、远程接键数字信号识别等功能。我们选用MT8888双音多频(DTMF)收发器,与单片机及音频放大电路组合,实现各种信号音的检测及DTMF信号的产生,并将DTMF信号送到电话线上,如图3所示。 MT8888是采用CMOS工艺生产的DTMF信号收发一体的集成电路。它的发送部分采用信号失真小、频率稳定性高的开关电容式D/A变换器,可发出16种双音多频DTMF信号。接收部分用于完成DTMF信号的妆收、分离和译码,并以4位并行二进制码的方式输出。 图3 选择中断模式时,当接收或发送了有效的音频信号后IRQ/CP脚输出低电平,产生中断信号供给CPU,在延迟控制电压的跳变缘将数据锁存至输出端;当选择呼叫过程(CP)方式时,只能接收250~550Hz的信号音,在拒收或无输入时,IRQ/CP脚输出低电平。 (1)电话信号音格式 忙音:450Hz,350ms有,350ms无。拨号音:450Hz,持续。回铃音:450Hz,1s有,4s无。 (2)信号音的判断方式 将MT8888的IRQ/CP脚连到AT89S52的T0脚,电话呼叫过程中的各种信号音经MT8888滤波限幅后得到方波,由MT8888的IRQ输出到AT89S52的T0脚,对T0脚信号记数5s。计数值位于2175~2357范围内,为拨号音;计数值位于1041~1212范围内,为忙音;计数值位于425~475范围内,为回铃音。在实际编程中,考虑到计数的误差以及程序的简化,可将范围适当放宽,但不能重叠。 (3)自动摘机 控制器与家里电话并接在一条电话线上。为了实现报警放打电话共用一条线,摘机电路按如下设置:将电话振铃信号通过光电耦合器TP521输入到AT89S52的IT脚,进行计数。接到振铃信号时,若连续振铃10次用户还没有摘机,则自动转到家庭智能报警器,CPU置P1.5脚为“1”,使继电器K1吸合,实现自动摘机功能。若在这10次振铃过程中,用户接通了电话,则控制器不响应,这样,使得控制器与电话不互相干扰。摘机后,检测MT8888输出的双音多频信号,以读出用户发来的远程信息,实现远程通信与控制功能。 图4 (4)自动报警 当接收到热释电传感器等发来的无线报警信号后,CPU立即发出报警信号,通过电话线传到远程用户。报警方式如下:用户通过面板设备10个报警电话,将它们存入24C04存储器中。当接到警情后,从第1个电话开始拨号,一直拨到第10个,来回拨3遍。如果任意一个电话回送了“#”键确认信号,即意味着报警已收到,不再继续拨号。每个号码需拨号。每个号码需拨号时间100ms,号码之间留500ms间隔。拨号时,先检测24C04中存储的电话号码。若为空,即未设此电话,跳过不拨,继续拨下一个电话号码。这样,用户可随意设置数个报警电话号码。我们规定号码长度最多不超过4位,以便存在24C04中。 1.1.2 语音电路 为了便于通信,采用了语音芯片,实现语音指示和报警功能。ISD1420为单片语音记录、回放一体化芯片,记录时长为20s;可被划分为160小段,每段125ms。当REC脚为低电平时,进行录音,PLAYE或PLAYL为低时进行放音,ISD1420可进行连续录音,也可进行分段录音。 分段放音:先送停止录放音码P1.2~P1.4=000,再送放音首地址A7~A0,P1.3或P1.4为低电平(PLAYE或PLAYL)开始放音;延时进行放音,最后送停止录放音码P1.2~P1.4=000,完成本段放音。重复上述过程,可分段放出数段语音。图4为语音电路原理。 1.1.3 编/解码电路 PT2262/2272是台湾普城公司生产的一种CMOS工艺制造的低功耗、低价位、通用编解码电路。PT2262/2272最多可有12位(A0~A11)三态地址端引脚(悬空、接高电平、接低电平),任意组合可提供531441地址码。 PT2262最多可有6位(D0~D5)数据端引脚,设定的地址码和数据码从17脚串行输出。编码芯片PT2262发出的编码信号由地址码、数据码、同步码组成一个完整的码字。地址码必须与家庭控制主机内解码芯片PT2272编址相同,以区分家庭控制器;数据码可用于区分传感器类型。当有报警信号时,PT2262的14脚为低电平,使能PT2262,从17脚输出编码信号,通过射频模块发射出去。 解码芯片PT2272接收到信号后,其地址码经过两次比较核对,VT脚才输出高电平,送到89S52的INT1,触发中断处理程序,以读取D0~D3的数据码,得知报警传感器状态和报警类型。图5为编/解码电路原理。 1.1.4 射频发射模块与射频接收模块 射频发射模块与射频接收模块原理如图6和图7所示,工作频率为433MHz。最大传输距离可达1000m。 1.2 传感器设计 1.2.1 被动红外热释电传感器 人体有恒定的体温,一般在37℃,所以会发出特定波长为10μm左右的红外线。被动式红外探头就是靠探测人体发射的10μm左右的红外线而进行工作的。人体发射的10μm左右的红外线,通过菲涅尔滤光片增强后,聚集到红外感应源上。红外感应源泉通常采用热释电元件。这种元件在接收到人体红外辐射温度发生变化时将会失去电荷平衡,向外释放电荷,后续电路经检测处理后产生报警信号。 图8为双元热释电红外检测元件LHI968的内部电路。它由两个双元热释电陶瓷,感应红外信号,再经场效应管放大输出。D端的电阻和S端的电容具有抗电磁干扰能力。 图7 信号从S端引出经前级放大,通过47μF电容后再次放大,与设定门限电压进行比较,获得报警输出信号。47μF电容能够除直流成分,从而消除了使用环境(阳光、灯光、火源泉等)对探测器的影响,后面再加一延时触发电路以便主人设防与撤防。现在已有专用集成芯片BISS0001实现以上功能。为了适应主人进门时撤防的需要,设计一报警延时电路。延时长度须满足:当人以1m/s的速度从探测器的正前方移动0.2m,不产生报警;但移动3m应报警,测试速度应能检测0.3~3m/s或更宽的速度范围。 1.2.2 门磁传大吃一惊器 无线门磁传感器一般案卷在门内侧的上方。它由两部分组成:较小的部件为永磁体,内部有一块永久磁铁,用来产生恒定的磁场;较大的是无线门磁主体,内部有一个常开型的干簧管。当永磁体和干簧管靠得很近时(小于5mm),无线门磁传感器处于工作守候状态;当永磁体离开干簧管一定距离后,无线门磁传感器立即发射包含地址编码和自身识别码(也就是数据码)的433MHz的高频无线电信号。主机通过识别这个无线电信号的地址码,判断是否为同一个报警系统,然后根据自身识别码(也就是数据码),确定是哪一个无线门磁报警。 2 网络中心控制主机设计 网络中心控制主机设计与家庭控制器基本相同,只是加了一个RS232接口,实现与PC机相连。通过放在物管中心的PC机实现小区网络监控功能。 结语 采用现有电话网络,结合射频无线通信技术和单片机网络控制技术,使本防盗报警系统经济、可靠,组网灵活;家庭无需为传感器布线;具有广泛的市场发展前景。

火灾报警器毕业论文开题报告

1. 基于FX2N-48MRPLC的交通灯控制 2. 西门子PLC控制的四层电梯毕业设计论文 3. PLC电梯控制毕业论文 4. 基于plc的五层电梯控制 5. 松下PLC控制的五层电梯设计 6. 基于PLC控制的立体车库系统设计 7. PLC控制的花样喷泉 8. 三菱PLC控制的花样喷泉系统 9. PLC控制的抢答器设计 10. 世纪星组态 PLC控制的交通灯系统 11. X62W型卧式万能铣床设计 12. 四路抢答器PLC控制 13. PLC控制类毕业设计论文 14. 铁路与公路交叉口护栏自动控制系统 15. 基于PLC的机械手自动操作系统 16. 三相异步电动机正反转控制 17. 基于机械手分选大小球的自动控制 18. 基于PLC控制的作息时间控制系统 19. 变频恒压供水控制系统 20. PLC在电网备用自动投入中的应用 21. PLC在变电站变压器自动化中的应用 22. FX2系列PCL五层电梯控制系统 23. PLC控制的自动售货机毕业设计论文 24. 双恒压供水西门子PLC毕业设计 25. 交流变频调速PLC控制电梯系统设计毕业论文 26. 基于PLC的三层电梯控制系统设计 27. PLC控制自动门的课程设计 28. PLC控制锅炉输煤系统 29. PLC控制变频调速五层电梯系统设计 30. 机械手PLC控制设计 31. 基于PLC的组合机床控制系统设计 32. PLC在改造z-3040型摇臂钻床中的应用 33. 超高压水射流机器人切割系统电气控制设计 34. PLC在数控技术中进给系统的开发中的应用 35. PLC在船用牵引控制系统开发中的应用 36. 智能组合秤控制系统设计 37. S7-200PLC在数控车床控制系统中的应用 38. 自动送料装车系统PLC控制设计 39. 三菱PLC在五层电梯控制中的应用 40. PLC在交流双速电梯控制系统中的应用 41. PLC电梯控制毕业论文 42. 基于PLC的电机故障诊断系统设计 43. 欧姆龙PLC控制交通灯系统毕业论文 44. PLC在配料生产线上的应用毕业论文 45. 三菱PLC控制的四层电梯毕业设计论文 46. 全自动洗衣机PLC控制毕业设计论文 47. 工业洗衣机的PLC控制毕业论文 48. 《双恒压无塔供水的PLC电气控制》 49. 基于三菱PLC设计的四层电梯控制系统 50. 西门子PLC交通灯毕业设计 51. 自动铣床PLC控制系统毕业设计 52. PLC变频调速恒压供水系统 53. PLC控制的行车自动化控制系统 54. 基于PLC的自动售货机的设计 55. 基于PLC的气动机械手控制系统 56. PLC在电梯自动化控制中的应用 57. 组态控制交通灯 58. PLC控制的升降横移式自动化立体车库 59. PLC在电动单梁天车中的应用 60. PLC在液体混合控制系统中的应用 61. 基于西门子PLC控制的全自动洗衣机仿真设计 62. 基于三菱PLC控制的全自动洗衣机 63. 基于plc的污水处理系统 64. 恒压供水系统的PLC控制设计 65. 基于欧姆龙PLC的变频恒压供水系统设计 66. 西门子PLC编写的花样喷泉控制程序 67. 欧姆龙PLC编写的全自动洗衣机控制程序 68 景观温室控制系统的设计 69. 贮丝生产线PLC控制的系统 70. 基于PLC的霓虹灯控制系统 71. PLC在砂光机控制系统上的应用 72. 磨石粉生产线控制系统的设计 73. 自动药片装瓶机PLC控制设计 74. 装卸料小车多方式运行的PLC控制系统设计 75. PLC控制的自动罐装机系统 76. 基于CPLD的可控硅中频电源 77. 西门子PLC编写的花样喷泉控制程序 78. 欧姆龙PLC编写的全自动洗衣机控制程序 79. PLC在板式过滤器中的应用 80. PLC在粮食存储物流控制系统设计中的应用 81. 变频调速式疲劳试验装置控制系统设计 82. 基于PLC的贮料罐控制系统 83. 基于PLC的智能交通灯监控系统设计 1.基于labVIEW虚拟滤波器的设计与实现 2.双闭环直流调速系统设计 3.单片机脉搏测量仪 4.单片机控制的全自动洗衣机毕业设计论文 5.FPGA电梯控制的设计与实现 6.恒温箱单片机控制 7.基于单片机的数字电压表 8.单片机控制步进电机毕业设计论文 9.函数信号发生器设计论文 10.110KV变电所一次系统设计 11.报警门铃设计论文 12.51单片机交通灯控制 13.单片机温度控制系统 14.CDMA通信系统中的接入信道部分进行仿真与分析 15.仓库温湿度的监测系统 16.基于单片机的电子密码锁 17.单片机控制交通灯系统设计 18.基于DSP的IIR数字低通滤波器的设计与实现 19.智能抢答器设计 20.基于LabVIEW的PC机与单片机串口通信 21.DSP设计的IIR数字高通滤波器 22.单片机数字钟设计 23.自动起闭光控窗帘毕业设计论文 24.三容液位远程测控系统毕业论文 25.基于Matlab的PWM波形仿真与分析 26.集成功率放大电路的设计 27.波形发生器、频率计和数字电压表设计 28.水位遥测自控系统 毕业论文 29.宽带视频放大电路的设计 毕业设计 30.简易数字存储示波器设计毕业论文 31.球赛计时计分器 毕业设计论文 32.IIR数字滤波器的设计毕业论文 33.PC机与单片机串行通信毕业论文 34.基于CPLD的低频信号发生器设计毕业论文 35.110kV变电站电气主接线设计 36.m序列在扩频通信中的应用 37.正弦信号发生器 38.红外报警器设计与实现 39.开关稳压电源设计 40.基于MCS51单片机温度控制毕业设计论文 41.步进电动机竹竿舞健身娱乐器材 42.单片机控制步进电机 毕业设计论文 43.单片机汽车倒车测距仪 44.基于单片机的自行车测速系统设计 45.水电站电气一次及发电机保护 46.基于单片机的数字显示温度系统毕业设计论文 47.语音电子门锁设计与实现 48.工厂总降压变电所设计-毕业论文 49.单片机无线抢答器设计 50.基于单片机控制直流电机调速系统毕业设计论文 51.单片机串行通信发射部分毕业设计论文 52.基于VHDL语言PLD设计的出租车计费系统毕业设计论文 53.超声波测距仪毕业设计论文 54.单片机控制的数控电流源毕业设计论文 55.声控报警器毕业设计论文 56.基于单片机的锁相频率合成器毕业设计论文 57.基于Multism/protel的数字抢答器 58.单片机智能火灾报警器毕业设计论 59.无线多路遥控发射接收系统设计毕业论文 60.单片机对玩具小车的智能控制毕业设计论文 61.数字频率计毕业设计论文 62.基于单片机控制的电机交流调速毕业设计论文 63.楼宇自动化--毕业设计论文 64.车辆牌照图像识别算法的实现--毕业设计 65.超声波测距仪--毕业设计 66.工厂变电所一次侧电气设计 67.电子测频仪--毕业设计 68.点阵电子显示屏--毕业设计 69.电子电路的电子仿真实验研究 70.基于51单片机的多路温度采集控制系统 71.基于单片机的数字钟设计 72.小功率不间断电源(UPS)中变换器的原理与设计 73.自动存包柜的设计 74.空调器微电脑控制系统 75.全自动洗衣机控制器 76.电力线载波调制解调器毕业设计论文 77.图书馆照明控制系统设计 78.基于AC3的虚拟环绕声实现 79.电视伴音红外转发器的设计 80.多传感器障碍物检测系统的软件设计 81.基于单片机的电器遥控器设计 82.基于单片机的数码录音与播放系统 83.单片机控制的霓虹灯控制器 84.电阻炉温度控制系统 85.智能温度巡检仪的研制 86.保险箱遥控密码锁 毕业设计 87.10KV变电所的电气部分及继电保护 88.年产26000吨乙醇精馏装置设计 89.卷扬机自动控制限位控制系统 90.铁矿综合自动化调度系统 91.磁敏传感器水位控制系统 92.继电器控制两段传输带机电系统 93.广告灯自动控制系统 94.基于CFA的二阶滤波器设计 95.霍尔传感器水位控制系统 96.全自动车载饮水机 97.浮球液位传感器水位控制系统 98.干簧继电器水位控制系统 99.电接点压力表水位控制系统 100.低成本智能住宅监控系统的设计 101.大型发电厂的继电保护配置 102.直流操作电源监控系统的研究 103.悬挂运动控制系统 104.气体泄漏超声检测系统的设计 105.电压无功补偿综合控制装置 106.FC-TCR型无功补偿装置控制器的设计 107.DSP电机调速 108.150MHz频段窄带调频无线接收机 109.电子体温计 110.基于单片机的病床呼叫控制系统 111.红外测温仪 112.基于单片微型计算机的测距仪 113.智能数字频率计 114.基于单片微型计算机的多路室内火灾报警器 115.信号发生器 116.基于单片微型计算机的语音播出的作息时间控制器 117.交通信号灯控制电路的设计 118.基于单片机步进电机控制系统设计 119.多路数据采集系统的设计 120.电子万年历 121.遥控式数控电源设计 122.110kV降压变电所一次系统设计 123.220kv变电站一次系统设计 124.智能数字频率计 125.信号发生器 126.基于虚拟仪器的电网主要电气参数测试设计 127.基于FPGA的电网基本电量数字测量系统的设计 128.风力发电电能变换装置的研究与设计 129.电流继电器设计 130.大功率电器智能识别与用电安全控制器的设计 131.交流电机型式试验及计算机软件的研究 132.单片机交通灯控制系统的设计 133.智能立体仓库系统的设计 134.智能火灾报警监测系统 135.基于单片机的多点温度检测系统 136.单片机定时闹钟设计 137.湿度传感器单片机检测电路制作 138.智能小车自动寻址设计--小车悬挂运动控制系统 139.探讨未来通信技术的发展趋势 140.音频多重混响设计 141.单片机呼叫系统的设计 142.基于FPGA和锁相环4046实现波形发生器 143.基于FPGA的数字通信系统 144.基于单片机的带智能自动化的红外遥控小车 145.基于单片机AT89C51的语音温度计的设计 146.智能楼宇设计 147.移动电话接收机功能电路 148.单片机演奏音乐歌曲装置的设计 149.单片机电铃系统设计 150.智能电子密码锁设计 151.八路智能抢答器设计 152.组态控制抢答器系统设计 153.组态控制皮带运输机系统设计 154..基于单片机控制音乐门铃 155.基于单片机控制文字的显示 156.基于单片机控制发生的数字音乐盒 157.基于单片机控制动态扫描文字显示系统的设计 158.基于LMS自适应滤波器的MATLAB实现 159.D功率放大器毕业论文 160.无线射频识别系统发射接收硬件电路的设计 161.基于单片机PIC16F877的环境监测系统的设计 162.基于ADE7758的电能监测系统的设计 163.智能电话报警器 164.数字频率计 课程设计 165.多功能数字钟电路设计 课程设计 166.基于VHDL数字频率计的设计与仿真 167.基于单片机控制的电子秤 168.基于单片机的智能电子负载系统设计 169.电压比较器的模拟与仿真 170.脉冲变压器设计 171.MATLAB仿真技术及应用 172.基于单片机的水温控制系统 173.基于FPGA和单片机的多功能等精度频率计 174.发电机-变压器组中微型机保护系统 175.基于单片机的鸡雏恒温孵化器的设计 176.数字温度计的设计 177.生产流水线产品产量统计显示系统 178.水位报警显时控制系统的设计 179.红外遥控电子密码锁的设计 180.基于MCU温控智能风扇控制系统的设计 181.数字电容测量仪的设计 182.基于单片机的遥控器的设计 183.200电话卡代拨器的设计 184.数字式心电信号发生器硬件设计及波形输出实现 185.电压稳定毕业设计论文 186.基于DSP的短波通信系统设计(IIR设计) 187.一氧化碳报警器 188.网络视频监控系统的设计 189.全氢罩式退火炉温度控制系统 190.通用串行总线数据采集卡的设计 191.单片机控制单闭环直流电动机的调速控制系统 192.单片机电加热炉温度控制系统 193.单片机大型建筑火灾监控系统 194.USB接口设备驱动程序的框架设计 195.基于Matlab的多频率FMICW的信号分离及时延信息提取 196.正弦信号发生器 197.小功率UPS系统设计 198.全数字控制SPWM单相变频器 199.点阵式汉字电子显示屏的设计与制作 200.基于AT89C51的路灯控制系统设计 200.基于AT89C51的路灯控制系统设计 201.基于AT89C51的宽范围高精度的电机转速测量系统 202.开关电源设计 203.基于PDIUSBD12和K9F2808简易USB闪存设计 204.微型机控制一体化监控系统 205.直流电机试验自动采集与控制系统的设计 206.新型自动装弹机控制系统的研究与开发 207.交流异步电机试验自动采集与控制系统的设计 208.转速闭环控制的直流调速系统的仿真与设计 209.基于单片机的数字直流调速系统设计 210.多功能频率计的设计 211.18信息移频信号的频谱分析和识别 212.集散管理系统—终端设计 213.基于MATLAB的数字滤波器优化设计 214.基于AT89C51SND1C的MP3播放器 215.基于光纤的汽车CAN总线研究 216.汽车倒车雷达 217.基于DSP的电机控制 218.超媒体技术 219.数字电子钟的设计与制作 220.温度报警器的电路设计与制作 221.数字电子钟的电路设计 222.鸡舍电子智能补光器的设计 223.高精度超声波传感器信号调理电路的设计 224.电子密码锁的电路设计与制作 225.单片机控制电梯系统的设计 226.常用电器维修方法综述 227.控制式智能计热表的设计 228.电子指南针设计 229.汽车防撞主控系统设计 230.单片机的智能电源管理系统 231.电力电子技术在绿色照明电路中的应用 232.电气火灾自动保护型断路器的设计 233.基于单片机的多功能智能小车设计 234.对漏电保护器安全性能的剖析 235.解析民用建筑的应急照明 236.电力拖动控制系统设计 237.低频功率放大器设计 238.银行自动报警系统

1、选用什么单片机2、选用什么传感器3、显示用什么4、需要远程报警吗

基于单片机语音数字联网火灾报警器设计 摘 要:使用AT89C51单片机,选用集成温度传感器AD590和气体传感器TGS202作为敏感元件,利用多传感器信息融合技术,开发了可用于小型单位火灾报警的语音数字联网报警器。 关键词:单片机;传感器;信号处理;火灾报警器 1 引 言 我国的火灾自动报警控制系统经历了从无到有、从简单到复杂的发展过程,其智能化程度也越来越高。目前国内厂家多偏重用于大型仓库、商场、高级写字楼、宾馆等场所大型火灾报警系统的研发,他们采用集中区域报警控制方式,其系统复杂、成本较高。而在居民住宅区、机房、办公室等小型防火单位,需要设置一种单一或区域联网、廉价实用的火灾自动探测报警装置,因此,研制一种结构简单、价格低廉的语音数字联网火灾报警器是非常必要的。 一般小型防火单位火灾报警系统如图1所示。现场火灾报警器通过对传感器火情信息的检测,使用智能识别算法实现对火灾的监测。当报警器监测到火情信息后,直接通过Modem经公用电话交换网迅速向消防指挥中心报告火情信息(包括火灾单位编码、单位名称、火情级别以及报警时间等),同时产生声光报警信号,并按事先预留的电话号码自动拨号通知单位有关负责人。消防指挥中心根据接收到的火警信息,立即在消防信息数据库中查询单位位置、周围道路、交通、水源情况等基本信息,根据所获得的信息迅速确定最佳救火方案,通过网络将出警命令直接下达各消防中队。本文将详细介绍小型防火单位语音数字联网报警器的设计与实现。 2 报警器硬件设计 2.1 硬件组成 如图2所示,报警器硬件由温度烟雾信号采集模块、声光报警模块以及单片机与Modem通信模块组成。图中1,2,3组成数据采集模块,4,5组成声光报警模块,5,6,7组成与Modem通信模块。其中,1为传感器(包括烟感和温感),将现场温度、烟雾等非电信号转化为电信号;2为信号调理电路,将传感器输出的电信号进行调理(放大、滤波等),使之满足A/D转换的要求;3为A/D转换电路,完成将温度传感器和烟雾传感器输出的模拟信号到数字信号的转换。声光报警模块由单片机和报警电路组成,由单片机控制实现不同的声光报警(异常报警、故障报警、火灾报警)功能。单片机与Modem通信模块由单片机、GM16C550串行端口扩展芯片和RS232电平转换电路组成,实现报警器经Modem与消防指挥中心的通信。下面对上述各模块进行简要介绍。 2.2 温度烟雾信号采集模块 要准确地进行火灾报警,选择合适的温度和烟雾传感器是准确报警的前提。综合考虑各因素,本文选择集成温度传感器AD590和气体传感器TGS202用作采集系统的敏感元件。 AD590是美国Analog Devices公司生产的一种电流型二端温度传感器。电路如图3所示。由于AD590是电流型温度传感器,他的输出同绝对温度成正比,即1μA/k,而数模转换芯片ADC0809的输入要求是电压量,所以在AD590的负极接出一个10 kΩ的电阻R1和一个100Ω的可调电阻W,将电流量变为电压量送入ADC0809。通过调节可调电阻,便可在输出端VT获得与绝对温度成正比的电压量,即10 mV/K。 火灾中气体烟雾主要是CO2和CO。TGS202气体传感器能探测CO2,CO,甲烷、煤气等多种气体,他灵敏度高,稳定性好,适合于火灾中气体的探测。如图4所示,当TGS202探测到CO2或CO时,传感器的内阻变小,VA迅速上升。选择适当的电阻阻值,使得当气体浓度达到一定程度(如CO浓度达到0.06%)时,VA端获得适当的电压(设为3 V)。 A/D转换电路采用了常用的8位8通道数模转换专用芯片ADC0809,电路如图5所示。温度、烟雾传感器的输出分别接到ADC0809的IN0和IN1。ADC0809的通道选择地址A,B,C分别由89C51的P0.0~P0.2经地址锁存器74LS373输出提供。当P2.7=0时,与写信号WR共同选通ADC0809。图中ALE信号与ST信号连在一起,在WR信 号的前沿写入地址信号,在其后沿启动转换。例如,输出地址7FF8H可选通通道IN0,实现对温度传感器输出的模拟量进行转换;输出地址7FF9H可选通通道IN1,实现对烟雾传感器输出的模拟量进行转换。图中ADC0809的转换结束状态信号EOC接到89C51的INT1引脚,当A/D转换完成后,EOC变为高电平,表示转换结束,产生中断。在中断服务程序中,将转换好的数据送到指定的存储单元。 2.3 声光报警模块 声光报警电路在单片机P1口的控制下,可以根据不同情况(火灾、异常、故障)发出不同的声光报警信号。声音信号由专用语音芯片提供。通过给语音芯片的S1和S2端输入不同的逻辑电平(00,01,10,11),便可以获得4种不同的声音信号。由单片机的P1.0和P1.1控制。另外该芯片还需要一个选通信号,由P1.3提供。只有当该信号为高电平时,芯片才会根据S1和S2端的控制信号发出不同的报警声,否则不会发声报警。 由P1口的P1.4~P1.7分别控制4个发光二极管,予以光报警,如图6所示。P1.4~P1.7控制的灯依次为绿色(正常信号灯)、黄色(故障信号灯)、红色(异常信号灯)和红色(火灾信号灯)。当这些输出端输出低电平时,对应的信号灯便会发光报警。 2.4 单片机与Modem通信模块 当报警器监测到火灾信息后,除了在火灾现场产生声光报警信号外,还需要将火灾信息按事先预留的电话号码自动拨号通知单位有关人员,并迅速上报消防指挥中心,为此,系统设计了单片机与Modem通讯模块,该模块由单片机、GM16C550串行端口扩展芯片和RS232电平转换电路组成。限于篇幅,对通讯模块的硬件电路及编程不做详细论述。 3 报警器监控程序设计 监控程序流程图如图7所示。系统复位后,首先要进行初始化,包括对各个控制用寄存器的初始化、设置中断服务程序的入口地址、设置堆栈等。 为了便于系统维护和功能扩充,采用了模块化程序设计方法,系统各个模块的具体功能都是通过子程序调用实现的。本系统主要包括数据采集子程序、火灾判断与报警子程序以及Modem通讯子程序等。 3.1 数据采集子程序 数据采集部分的程序设计包括:驱动ADC0809的IN0和IN1进行A/D转换,分别由子程序ADC1(温度转换)和ADC2(烟雾浓度转换)完成;单片机接收转换好的数据,存入指定内存单元,由INT1中断服务程序完成。每次驱动A/D转换后等待外部中断1,中断到来说明A/D转换已经完成,通过中断服务程序读取转换得到的数据。 3.2 火灾判断与报警程序 为了降低误报率,系统采用了多次采集、多次判断的方法。每次数据采集后根据得到的数据对现场情况进行判断:00H表示正常、01H表示异常、02H表示火灾;然后综合多次判断结果做出最终的火情判断。数据在内部RAM存储单元中的存放情况如表1所示。具体判断方法如下: (1)对温度和烟雾进行了两次数据采集与判断 温度≥100℃,温度异常,置标志位为1,否则为0;烟雾(CO,CO2)浓度≥0.06%,烟雾浓度异常,置标志位为1,否则为0。 (2)根据温度和烟雾的异常标志位判断现场情况 2个标志位均为0,表示情况正常,给53H或56H单元送00H;2个中仅有1个为1,表示情况异常,送01H;2个均为1,表示有火灾发生,送02H。 (3)综合两次情况做最后判断,并予以报警 若53H和56H中数据不相同,说明是误报,调故障报警子程序;否则按该单元中的数据调相应的报警子程序。 00H为情况正常,返回。 01H为情况异常,调异常报警子程序。 02H为现场有火灾,调火灾报警子程序,并向消防中心报告火情。 4 结 语 本文研制的用于小型防火单位的语音数字联网火灾报警器具有以下特点: (1)能对室内烟雾(CO2,CO)及温度突变进行报警(声光报警)。 (2)如果出现硬件故障(如传感器遗落、内部元器件损坏等),能发出故障报警。 (3)如果只有一种参数出现异常(如烟雾浓度过大或是温度较高),能发出异常报警信号,令值班人员到现场处理。 (4)如果烟雾和温度同时出现异常,则说明有火灾,发出火灾警报,并及时将火灾信息上报消防指挥中心。 现场模拟实验表明,本系统安全可靠,误报率低。且由于其体积小、操作维护方便、成本低廉等,具有广阔的应用前景。

相关百科

热门百科

首页
发表服务