首页

> 学术论文知识库

首页 学术论文知识库 问题

给水厂设计英文论文参考文献

发布时间:

给水厂设计英文论文参考文献

学位论文参考文献的格式

丨 期刊

期刊作者.题名[J].刊名,出版年,卷(期):起止页码

周庆荣,张泽廷,朱美文,等.固体溶质在含夹带剂超临界流体中的溶解度[J].化工学报,1995,46(3):317 323

Dobbs J M, WongJ M. Modification of supercritical fluid phasebehavior using polorcoselvent[J]. Ind Eng Chem Res, 1987,26:56

刘仲能,金文清.合成医药中间体4-甲基咪唑的研究[J].精细化工,(2):103-105

Mesquita A C,Mori M N, Vieira J M, et al . Vinyl acetatepolymerization by ionizingradiation[J].Radiation Physics and Chemistry,2002, 63:465

丨 专著

专著作者.书名[M].版本(第一版不著录).出版地:出版者,出版年.起止页码

蒋挺大.亮聚糖[M].北京:化学工业出版社,

Kortun Spectroscopy[M]. New York: Spring-Verlag,1969

丨 论文集

论文集作者.题名[C].编者.论文集名.出版地:出版者,出版年.起止页码

郭宏,王熊,刘宗林.膜分离技术在大豆分离蛋白生产中综合利用的研究[C].余立新.第三届全国膜和膜过程学术报告会议论文集.北京:高教出版社,

Eiben A E,vander Hauw J 3-SAT with adaptive geneticalgorithms [C].Proc 4th IEEEConfEvolutionary Press,

丨 学位论文

学位论文作者.题名[D].保存地点:保存单位,年份

陈金梅.氟石膏生产早强快硬水泥的试验研究(D).西安:西安建筑科学大学,2000

ChrisstoffelsL A J . Carrier-facilitated transport as a mechanistic tool insupramolecular chemistry[D].The Netherland:

丨 专利文献

专利文献题名[P].国别,专利文献种类,专利号.出版日期

仲前昌夫, 佐藤寿昭. 感光性树脂[ P ]. 日本, 特开平

Hasegawa,Toshiyuki, Yoshida,et Coating composition[P].EP

Yamaguchi K,Hayashi A. Plant growth promotor and productionthereof [P].Jpn,

丨 技术标准文献

标准标准编号,标准名称[S]

ISO 1210-1982,塑料 小试样接触火焰法测定塑料燃烧性[S]

GB 2410-80,透明塑料透光率及雾度实验方法[S]

丨 报纸

报纸作者.题名[N].报纸名,出版日期(版次)

陈志平.减灾设计研究新动态[N].科技日报,1997-12-12(5)

丨 报告

报告作者.题名[R].保存地点:年份

中国机械工程学会.密相气力输送技术[R].北京:1996

丨 电子文献

电子文献作者.题名[电子文献及载体类型标识].文献出处,日期

万锦柔.中国大学学报论文文摘(1983-1993)[DB/CD].北京:中国百科全书出版社,1996

文献类型及其标识

根据GB3469 规定:

①期刊[J]

②专著[M]

③论文集[C]

④学位论文[D]

⑤专利[P]

⑥标准[S]

⑦报纸[N]

⑧技术报告[R]

电子文献载体类型用双字母标识,例如:

①磁带[MT]

②磁盘[DK]

③光盘[CD]

④联机网络[OL]

①联机网上数据库[DB/OL]

②磁带数据库[DB/MT]

③光盘图书[M/CD]

④磁盘软件[CP/DK]

⑤网上期刊[J/OL]

⑥网上电子公告[EB/OL]

英文文献采用 APA格式

丨 单一作者著作的书籍:

姓,名字首字母.(年). 书名(斜体). 出版社所在城市:出版社.

Sheril, R. D.(1956). The terrifying future: Contemplating color television. San Diego:Halstead.

英语论文参考文献标准格式

在各领域中,说到论文,大家肯定都不陌生吧,通过论文写作可以培养我们独立思考和创新的能力。那么一般论文是怎么写的呢?以下是我帮大家整理的英语论文参考文献标准格式,仅供参考,大家一起来看看吧。

用Times New Roman.每一条目顶格,如某一条目超过一行,从第二行起“悬挂缩进”2字符。参考文献中所有标点与符号均在英文状态下输入,标点符号后空一格。

参考文献条目排列顺序:英文文献、中文文献、网络文献。分别按作者姓氏字母顺序排列。文献前不用序号。

1)英文参考文献:

(1)专著与编著

排列顺序为:作者姓、名、专著名、出版地、出版社、出版年。

例如:

Brinkleyork: Knopf, 1993.

专著名中如果还包含其他著作或作品名,后者用斜体。

例如:

Dunn, Richard J ed. Charlotte Bront: Jane EyreNew York: Norton, 1971.

A、两个至三个作者

第一作者的姓在前,名在后,中间用逗号隔开;其余作者名在前,姓在后,中间无逗号;每个作者之间用逗号隔开,最后一个作者的姓名前用“and”,后用句号。

例如:

B、三个以上作者

第一作者姓名(姓在前,名在后,中间加逗号)后接“et al.”,其他作者姓名省略。

例如:

University of Hawaii Press, 1997.

C、同一作者同一年出版的不同文献,参照下例:

Widdowson, Henry G1998a.

Widdowson, Henry G. Cambridge:

Cambridge University Press, 1998b.

(2)论文集

参照下例:

Thompson, Pett. “Modal Verbs in Academic Writing”. In Ben Kettlemann & York: Rodopi, 2002: 305-323.

(3)百科全书等参考文献

参照下例:

Fagan, Jeffrey. “Gangs and Drugs”. ork: Macmillan, 2001.

(4)学术期刊论文

参照下例:

Murphy, Karen. “Meaningful Connections: Using Technology in Primary Classrooms”.

(5)网络文献

参照下例:

“Everything You Ever Wanted to Know About URL”.

(6)专著:

参照下例:

皮亚杰.结构主义[M] .北京:商务印书馆,1984.

(7)期刊文章:

参照下例:

杨忠,张韶杰.认知语音学中的类典型论[J].外语教学与研究,1999,(2):1-3.

(8)学位论文

参照下例:

梁佳.大学英语四、六级测试试题现状的理论分析与问题研究[D].湖南大学,2002.

(9)论文集

参照下例:

许小纯.含义和话语结构[A].李红儒.外国语言与文学研究[C].哈尔滨:黑龙江人民出版社,1999:5-7.

(10)附录

2)中文参考文献

一、参考文献的类型

参考文献(即引文出处)的类型以单字母方式标识,具体如下:

[M]--专着,着作

[C]--论文集(一般指会议发表的论文续集,及一些专题论文集,如《***大学研究生学术论文集》

[N]-- 报纸文章

[J]--期刊文章:发表在期刊上的论文,尽管有时我们看到的是从网上下载的(如知网),但它也是发表在期刊上的,你看到的电子期刊仅是其电子版

[D]--学位论文 :不区分硕士还是博士论文

[R]--报告:一般在标题中会有“关于****的.报告”字样

[S]-- 标准

[P]--专利

[A]--文章:很少用,主要是不属于以上类型的文章

[Z]--对于不属于上述的文献类型,可用字母“Z”标识,但这种情况非常少见

常用的电子文献及载体类型标识:

[DB/OL] --联机网上数据(database online)

[DB/MT] --磁带数据库(database on magnetic tape)

[M/CD] --光盘图书(monograph on CDROM)

[CP/DK] --磁盘软件(computer program on disk)

[J/OL] --网上期刊(serial online)

[EB/OL] --网上电子公告(electronic bulletin board online)

很显然,标识的就是该资源的英文缩写,/前面表示类型,/后面表示资源的载体,如OL表示在线资源。

二、参考文献的格式及举例

1.期刊类

【格式】[序号]作者。篇名[J].刊名,出版年份,卷号(期号)起止页码。

【举例】

[1] 周融,任志国,杨尚雷,厉星星。对新形势下毕业设计管理工作的思考与实践[J].电气电子教学学报,2003(6):107-109.

[2] 夏鲁惠。高等学校毕业设计(论文)教学情况调研报告[J].高等理科教育,2004(1):46-52.

[3] Heider, . The structure of color space in naming and memory of two languages [J]. Foreign Language Teaching and Research, 1999, (3): 62 67.

2.专着类

【格式】[序号]作者。书名[M].出版地:出版社,出版年份:起止页码。

【举例】

[4] 刘国钧,王连成。图书馆史研究[M].北京:高等教育出版社,1979:15-18,31.

[5] Gill, R. Mastering English Literature [M]. London: Macmillan, 1985: 42-45.

3.报纸类

【格式】[序号]作者。篇名[N].报纸名,出版日期(版次)。

【举例】

[6] 李大伦。经济全球化的重要性[N]. 光明日报,1998-12-27(3)。

[7] French, W. Between Silences: A Voice from China[N]. Atlantic Weekly, 1987-8-15(33)。

4.论文集

【格式】[序号]作者。篇名 [C].出版地:出版者,出版年份:起始页码。

【举例】

[8] 伍蠡甫。西方文论选[C]. 上海:上海译文出版社,1979:12-17.

[9] Spivak,G. “Can the Subaltern Speak?”[A]. In & L. Grossberg(eds.)。 Victory in Limbo: Imigism [C]. Urbana: University of Illinois Press, 1988, .

[10] Almarza, . Student foreign language teacher's knowledge growth [A]. In and (eds.)。 Teacher Learning in Language Teaching [C]. New York: Cambridge University Press. 1996. .

5.学位论文

【格式】[序号]作者。篇名[D].出版地:保存者,出版年份:起始页码。

【举例】

[11] 张筑生。微分半动力系统的不变集[D].北京:北京大学数学系数学研究所, 1983:1-7.

6.研究报告

【格式】[序号]作者。名[R].出版地:出版者,出版年份:起始页码。

【举例】

[12] 冯西桥。核反应堆压力管道与压力容器的LBB分析[R].北京:清华大学核能技术设计研究院, 1997:9-10.

7.专利

【格式】[序号]专利所有者。题名[P].国别:专利号,发布日期。

8.标准

【格式】[序号]标准编号,标准名称[S].

【举例】

[14] GB/T 16159-1996, 汉语拼音正词法基本规则 [S].

9.条例

【格式】[序号]颁布单位。条例名称。发布日期

【举例】

[15] 中华人民共和国科学技术委员会。科学技术期刊管理办法[Z].1991-06-05

10.电子文献

【格式】[序号]主要责任者。电子文献题名。电子文献出处[电子文献及载体类型标识].或可获得地址,发表或更新日期/引用日期。

【举例】

[16] 王明亮。关于中国学术期刊标准化数据库系统工程的进展[EB/OL].

[17] 万锦。中国大学学报论文文摘(1983 1993)。英文版 [DB/CD]. 北京: 中国大百科全书出版社, 1996.

11.各种未定义类型的文献

【格式】[序号] 主要责任者。文献题名[Z].出版地:出版者, 出版年。

特别说明:凡出现在“参考文献”项中的标点符号都失去了其原有意义,且其中所有标点必须是半角,如果你的输入法中有半角/全解转换,则换到半角状态就可以了,如果你的输入法中没有这一转换功能,直接关闭中文输入法,在英文输入状态下输入即可。

其实,很多输入法(如目前比较流行的搜狐输入法)都提供了四种组合:

(1)中文标点+ 全角:这时输入的标点是这样的,:【1】-(而这时,我没有找到哪个键可以输入 / 符号)也就是说,这些符号是一定不能出现在“参考文献”中的;

(2)中文标点+半角:这时输入的标点是这样的,:【1】-(这时,我还是没有找到哪个键可以输入 / 符号)也就是说,这些符号也不能出现在“参考文献”中的;

上面列出的符号,中间没有任何的空格,你能看出它们有什么区别吗?我看只是-的宽度有一点点不同,其它都一样

(3)英文标点+全角:这时输入的标点是这样的,.:[1]-/

(4)英文标点+半角:这时输入的标点是这样的,.:[1]-/

从这两项可以明显的看出,半角和全角其实最大的差别是所占的宽度不一样,这一点对于数字来说最为明显,而英文标点明显要比中文标点细小很多(也许因为英文中,标点的功能没有中文那么复杂,就是说英文中标点符号的能力没有中文那么强大)

所以,很多人在写“参考文献” 时,总是觉得用英文标点+半角很不清楚,间距也太小,其实这点完全不用担心如果你觉得真的太小不好看,就用英文标点+全角吧而在[1] 之后,一般也都有一个空格。

对于英文参考文献,还应注意以下两点:

①作者姓名采用“姓在前名在后”原则,具体格式是:姓,名字的首字母。 如: Malcolm Richard Cowley 应为:Cowley, .,如果有两位作者,第一位作者方式不变,&之后第二位作者名字的首字母放在前面,姓放在后面,如:Frank Norris 与Irving Gordon应为:Norris, F. & .

②书名、报刊名使用斜体字,如:Mastering English Literature,English Weekly.

三、注释

注释是对论文正文中某一特定内容的进一步解释或补充说明注释应置于本页页脚,前面用圈码①、②、③等标识。

付了 点我用户名,空间博文有介绍详细各种论文检测系统软件介绍见我空间各种有效论文修改秘籍

一般来说是刊号,就是第几期的意思

给水处理厂初步设计毕业论文

水处理技术 创刊于1975年,主要报道各种水处理方法的研究和应用成果,尤其是膜技术在水处理、化工、电力、电子、煤炭、医药、食品、纺织、冶金、铁路、环保、军事等领域的应用成果,同时为水源开发、工业用水除盐、工艺用水处理、超纯水制备、废水治理、水再生回用、海水淡化提供有效的新技术。 《水处理技术》为环境类中文核心期刊,“中国期刊方阵”期刊,全国科技论文统计源期刊,中国科学引文数据库来源期刊。本刊论文被美国CA和日本科技文献速报摘录。曾多次荣获国家海洋局、华东地区和浙江省优秀期刊奖。 《水处理技术》已加入《中国学术期刊(光盘版)》和“中国期刊网”、“万方数据资源系统”、“中文科技期刊数据库”。 1、公司依托独特而实用的水基化学向华理论和先进的水质分析仪器,可以对客户的水质情况进行系统的分析,根据水质情况及处理要求,筛选最佳水处理药剂,制定最佳处理工艺。 2、对客户现有的效果不理想的水处理系统进行改造,使出水水质达到回用要求或达标排放。 3、提供各种工业废水快速高效脱色技术,处理速度快,基建投资小,运行成本低,操作简单,去除SS、COD、BOD效果好。 4、特别提供低成本造纸黑液处理技术,造纸中段水处理技术,造纸白水回用技术。 5、提供多种工业废水处理小试、初步设计、中试、工程调试及人员培训。小试、初步设计不收费。渗透技术 反渗透技术是当今最先进和最节能有效的膜分离技术。其原理是在高于溶液渗透压的作用下,依据其他物质不能透过半透膜而将这些物质和水分离开来。由于反渗透膜的膜孔径非常小(仅为10A左右),因此能够有效地去除水中的溶解盐类、胶体、微生物、有机物等(去除率高达97%-98%)。反渗透是目前高纯水设备中应用最广泛的一种脱盐技术,它的分离对象是溶液中的离子范围和分子量几百的有机物;反渗透(RO)、超过滤(UF)、微孔膜过滤(MF)和电渗析(EDI)技术都属于膜分离技术。 近30年来,反渗透、电渗析、超过滤和膜过滤已进入工业应用,主要应用于电子、化工、食品、制药及饮用纯水等领域。反渗透的原理: 首先要了解“渗透”的概念.渗透是一种物理现象.当两种含有不同盐类的水,如用一张半渗透性的薄膜分开就会发现,含盐量少的一边的水分会透过膜渗到含盐量高的水中,而所含的盐分并不渗透,这样,逐渐把两边的含盐浓度融合到均等为止.然而,要完成这一过程需要很长时间,这一过程也称为渗透压力.但如果在含盐量高的水侧,试加一个压力,其结果也可以使上述渗透停止,这时的压力称为渗透压力.如果压力再加大,可以使方向相反方向渗透,而盐分剩下.因此,反渗透除盐原理,就是在有盐分的水中(如原水),施以比自然渗透压力更大的压力,使渗透向相反方向进行,把原水中的水分子压力到膜的另一边,变成洁净的水,从而达到除去水中杂质、盐分的目的.RO反渗透的由来: 1950年美国科学家有一回无意发现海鸥在海上飞行时从海面啜起一大口海水,隔了几秒后,吐出一小口的海水,而产生疑问,因为陆地上由肺呼吸的动物是绝对无法饮用高盐份的海水的.经过解剖发现海鸥体内有一层薄膜,该薄膜非常精密,海水经由海鸥吸入体内后加压,再经由压力作用将水分子贯穿渗透过薄膜转化为淡水,而含有杂质及高浓缩盐份的海水则吐出嘴外,此即往后反渗透法的基本理论架构;并在1953年由University of Florida应用于海水淡化去除盐份设备,在1960年经美国联邦政府专案支助美国大学医学院教授 Lode配合博士着手研究反渗透膜,一年约投入四亿美元经费研究,以运用于太空人使用,使太空船不用运载大量的饮用水升空,直到1960年投入研究工作的学者、专家越来越多,使之质与量更加精进,从而解决了人类钦用水中的难题. 混合床在同一个交换器中,将阴阳离子交换树脂按照一定的体积比例进行填装,在均匀混合状态下,进行阴阳离子交换,从而除去水中的盐分.混合床的阴阳离子交换树脂在交换过程中,由于是处于均匀混合状态,交错排列,互相接触,可以看作是由许许多多的阴阳离子交换树脂而组成的多级式复床,因为均匀混合,所以阴阳离子的交换反应几乎是同时进行的,所产生的H+ 和OH- 随即合成H2O,交换反应进行得很彻底,出水水质稳定.混合床常见的工艺流程有:一级反渗透系统→混合床 阳床→阴床→混合床二级反渗透系统→EDI设备出水量的大小根据客户的要求设计,设备的工艺根据当地的水质状况做相应的改进,设备材料的选型又可根据您的需求做相应的调整设备操作中常见的几种疑问: 设备使用周期短:系统设计不合理、进水水质某种成份偏高、阴树脂未完全再生起来等 设备出水PH值偏出正常范围:罐体内某种树脂未完全再生好、阴树脂被污染再生不起等 树脂变色:树脂受到重金属(如Fe)等物质污染失效 树脂再生不起:药剂投放量不够、树脂失效、再生液未清洗干净、树脂再生是未分好层、树脂再生后未混合均匀等。软化水设备软化水处理是利用阳离子交换树脂中可交换的阳离子,把水中所含的钙、镁离子交换出来,典型反映可用下列离子反应式表示:Ca2++2RNa=R2Ca+2Na+Mg2++2RNa=RMg+2Na+当水流经树脂层后出水硬度超过某一规定值后,离子交换树脂饱合,不再起软化作用,为恢复离子交换树脂的交换能力对离子交换树脂进行再生(“又称还原”)。□ 软水设备怎样选型 软水设备怎样选型? 只要您了解并提供给我们技术部以下参数,就可以较准确的选择适合贵单位系统设备所要求的软化设备了。 ◇ 1.首先您要提供所需要使用软化水的系统是:工艺用水?采暖?冷却补水?蒸汽锅炉?钢铁冶炼行业?化工制药行业? ◇ 2.系统用水时间:明确运行时间/小时用水量/平均值/峰值流量/ 用户是否需要连续供水?若需要则选择单阀双罐或双控双床系列,否则可选单阀单罐系统。 ◇ 3.源水总硬度?:水源是市政自来水?地下水?地表水源(江,河,湖水)您需提供使用地区的原水硬度。对一定型号的软水设备来说水硬度高,其周期制水量必然要少,由此而来导致再生频繁。对树脂的使用寿命不利。为避免这种情况出现,应加大树脂体积,这意味着选用加大型号的软水设备。 如果您不了解所用水源的水质情况,您可以委托给我公司的分析实验室,我们提供免费的常规水质分析。 ◇ 4、 所需的软水单位流量(吨/小时)。这由用户设备的性质和要求决定,以此选定标准型号的软水设备; ◇ 5、周期制水量的设定 在软水设备型号设定之后,根据原水硬度,所用树脂的交换工作容量就可以确定理论周期制水量(吨)。 软化设备选型须知 ◇ 1、控制器:完全采用美国FLECK富莱克、AUTOTROL阿图祖自动控制阀 ◇ 2、树脂罐:可供选择:国产RFP罐、金属内衬塑罐(PE内衬) 进口(斯特洛)RFP罐 ◇ 3、设备运行控制形式: L—流量型:制备水量达到设定值时自动还原,可适用于所有的给水系统软水制备。 S—时间型:以时间为控制再生计量方式,适合用水量稳定的系统供水,最短还原再生 周期为24小时。 ◇ 4、可供选择的设备组合: ⑴—单控单床:还原期间停止供水2小时或继续供原水(硬水旁通)。 ⑵—单控双床:交替供水,一用一备型。 ⑶—双控双床:交替供水,一用一备型。 ⑷—双控双床:同时供水,交替再生。 ⑸—多控几床:三个以上树脂罐并联使用,适合大型供水系统。 注:应根据所处理的原水硬度值选型。如属高硬度水(>8mmol/L时),建议加大一级选型;>12mmol/L时,应采用二次软化或配合其它方法. 我公司可免费为用户提供常规水质分析,外阜客户可通过邮寄方式。 注:如果您需要经济的选型方案的话,请电话或传真给我公司技术部,一定会给您一个满意的回复。

水处理是指为达到成品水的水质要求而对原水的加工过程。下面是我整理的关于水处理技术论文,希望你能从中得到感悟!

关于水处理技术的分析

摘要:本文作者介绍了水处理的概念,对水处理技术进行了分析介绍,供大家参考借鉴。

关键词:水处理;技术;分析

中图分类号:TU7 文献标识码:A 文章编号:

简单讲,“水处理”便是通过物理、化学手段,去除水中一些对生产、生活不需要的物质的过程。是为了适用特定的用途而对水进行的沉降、过滤、混凝、絮凝,以及缓蚀、阻垢等水质调理的过程。由于社会生产、生活与水密切相关,因此,水处理领域涉及的应用范围十分广泛,了解水处理的基本常识对于人们的生活具有非常重要的意义。近年来,随着我国经济的高速发展,水污染也在不断恶化,随着水质污染而引起的各种疾病,带来的各种行业危害日趋严重,水处理到如今就突显出其不可忽视的重要性。然而,真正对水处理方面的知识有些许了解的民众却并不多见。

1 水处理的概念

水处理是指为达到成品水的水质要求而对原水的加工过程。在循环用水系统以及水的再生处理中,原水是废水,成品水是用水,加工过程兼具给水处理和废水处理的性质。水处理还包括对处理过程中所产生的废水和污泥的处理及最终处置,有时还有废气的处理和排放问题。

2 水处理工艺

一级处理是机械处理工段,它通过机械处理,如格栅、沉淀或气浮,去除污水中所含的石块、砂石和脂肪、油脂等。机械处理工段包括格栅、沉砂池、初沉池等构筑物,以去除粗大颗粒和悬浮物为目的,处理的原理在于通过物理法实现固液分离,将污染物从污水中分离,这是普遍采用的污水处理方式。机械处理是所有污水处理工艺流程必备工程,城市污水一级处理BOD5和SS的典型去除率分别为25%和50%。在原污水水质特性不利于除磷脱氮的情况下,初沉的设置与否以及设置方式需要根据水质特注的后续工艺加以仔细分析和考虑,以保证和改善除磷除脱氮等后续工艺的进水水质。

二级处理是污水生化处理,生物处理,污水中的污染物在微生物的作用下被降解和转化为污泥。污水生化处理属于二级处理,以去除不可沉悬浮物和溶解性可生物降解有机物为主要目的,其工艺构成多种多样,可分成活性污泥法、AB法、A/O法、A2/O法、SBR法、氧化沟法、稳定塘法、土地处理法等多种处理方法。日前大多数城市污水处理厂都采用活性污泥法。在污水生化处理过程中,影响微生物活性的因素可分为基质类和环境类两大类:

基质类包括以碳元素为主的有机化合物即碳源物质、氮源、磷源等营养物质及一些有毒有害化学物质如酚类、苯类等化合物、也包括一些重金属离子如铜、镉、铅离子等。

环境类影响因素指污水处理中绝大部分微生物最适宜生长的温度范围是20-30℃,活性污泥系统微生物最适宜的PH值范围是,曝气池出口处的溶解氧以保持2mg/l左右为宜。

三级处理是污水的深度处理,它包括营养物的去除和通过加氯、紫外辐射或臭氧技术对污水进行消毒。三级处理是对水的深度处理,现在的我国的污水处理厂投入实际应用的并不多。它将经过二级处理的水进行脱氮、脱磷处理,用活性炭吸附法或反渗透法等去除水中的剩余污染物,并用臭氧或氯消毒杀灭细菌和病毒,然后将处理水送入中水道,作为冲洗厕所、喷洒街道、浇灌绿化带、工业用水、防火等水源。

3 水处理方法

沉淀物过滤法的目的是将水源内悬浮颗粒物质或胶体物质清除乾净。这些颗粒物质若没有清除,会对透析用水其它精密的过滤膜造成破坏或甚至水路的阻塞。这是最古老且最简单的净水法,所以这个步骤常用在水纯化的初步处理,或有必要时,在管路中也会多加入几个滤器以清除体积较大的杂质。滤过悬浮的颗粒物质所使用的滤器种类很多,例如网状滤器,沙状滤器或膜状滤器等。只要颗粒大小大於这些孔洞之大小,就会被阻挡下来。对於溶解於水中的离子,就无法阻拦下来。

硬水的软化需使用离子交换法,它的目的是利用阳离子交换树脂以钠离子来交换硬水中的钙与镁离子,*此来降低水源内之钙镁离子的浓度。通常的离子交换树脂为球状的合成有机物高分子电解质。树脂基质内藏氯化钠,在硬水软化的过程中,钠离子会逐渐被使用耗尽,则交换树脂的软化效果也会逐渐降低,这时需要作还原的工作,也就是每隔固定时间加入特定浓度的盐水,一般是10%,如果水处理的过程中没有阳离子的软化,不只是逆渗透膜上会有钙镁体的沉积以致降低功效甚至破坏逆渗透膜,同时人也容易得到硬水症候群。硬水软化器也会引起细菌繁殖的问题,所以设备上需要有逆冲的功能,一段时间後就要逆冲一次以防止太多杂质吸附其上。

活性碳是由木头,残木屑,水果核,椰子壳,煤炭或石油底渣等物质在高温下乾馏炭化而成,制成後还需以热空气或水蒸气加以活化。它的主要作用是清除氯与氯氨以及其它分子量在60到300道尔顿的溶解性有机物质。活性碳的表面呈颗粒状,内部是多孔的,孔内有许多小的毛细管,1g的活性碳内部表面积高达700-1400m2,而这些毛细管内表面及颗粒表面就是吸附作用之所在。影响活性碳清除有机物能力的因素有活性碳本身的面积,孔洞大小以及被清除有机物的分子量及其极性,它主要依物理的吸附能力来排除杂物,当吸附能力达饱合之後,吸附过多的杂质就会掉落下来污染下游的水质,所以必须定时利用逆冲的方式来清除吸附其上的杂质。

去离子法的目的是将溶解於水中的无机离子排除,与硬水软化器一样,也是利用离子交换树脂的原理。在这使用两种树脂-阳离子交换树脂与阴离子交换树脂。阳离子交换树脂利用氢离子来交换阳离子;而阴离子交换树脂则利用氢氧根离子来交换阴离子,氢离子与氢氧根离子互相结合成中性水。

逆渗透法可以有效的清除溶解於水中的无机物,有机物,细菌,热原及其它颗粒等,是透析用水之处理中最重要的一环。所谓渗透是指以半透膜隔开两种不同浓度的溶液,其中溶质不能透过半透膜,则浓度较低的一方水分子会通过半透膜到达浓度较高的另一方,直到两侧的浓度相等为止。在还没达到平衡之前,可以在浓度较高的一方逐渐施加压力,则前述之水分子移动状态会暂时停止,此时所需的压力叫作渗透压,如果施加的力量大於渗透压时,则水份的移动会反方向而行,也就是从高浓度的一例流向低浓度的一方,这种现象就叫作逆渗透。逆渗透的纯化效果可以达到离子的层面,对於单价离子的排除率可达90%-98%,而双价离子可达95%-99%左右。

超过滤法与逆渗透法类似,也是使用半透膜,但它无法控制离子的清除,因为膜之孔径较大,约10-200A之间。只能排除细菌,病毒,热原及颗粒状物等,对水溶性离子则无法滤过。超过滤法主要的作用是充当逆渗透法的前置处理以防止逆渗透膜被细菌污染。它也可用在水处理的最後步骤以防止上游的水在管路中被细菌污染。一般是利用进水压与出水压差来判断超过滤膜是否有效,与活性碳类似,平时是以逆冲法来清除附着其上的杂质。

蒸馏法是古老却也是有效的水处理法,它可以清除任何不可挥发性的杂质,但是无法排除可挥发性的污染物。

紫外线消毒法是目前常使用的方法之一,它的杀菌机转是破坏细菌核酸的生命遗传物质,使其无法繁殖,其中最重大的反应是核酸分子内的pyrimidine盐基变成双合体。一般是使用低压水银放电灯的人工波长的紫外线能量。

4 结束语

本文阐述了水处理的基本概念,介绍了水处理的工艺及处理方法,使人们了解到水处理实际上就是对水源水或不符合用水水质要求的水,采用物理、化学、生物等方法改善水质的过程。

参考文献:

[1] 吴弼人.水处理-城市的命脉[J].华东科技,2009,(06).

[2] 戴建强,郑敏.城市中水回用于电厂循环冷却水的处理技术实例[J].环境科学与管理,2011,(08).

点击下页还有更多>>>关于水处理技术论文

真宽泛。。。。想必是要毕业论文用吧?还是自己写的好

A2/O工艺处理城市污水(一) (2011-12-03 21:13:00)转载▼标签: 教育 分类: 博文 摘要本次毕业设计的题目为江阴某经济开发区污水处理厂设计— A2/O 工艺。主要任务是完成该经济开发区排水管网布置及污水处理厂初步设计和单项处理构筑物施工图设计。其中初步设计要完成设计说明书一份、污水处理厂总平面图一张及污水处理厂污水与污泥高程图一张;单项处理构筑物施工图设计中,主要是完成A2/O 平面图和剖面图及部分大样图。该污水处理厂工程,近期规模为万吨/日。该污水厂的污水处理流程为:从泵房到沉砂池,进入A2/O 反应池,进入辐流式二次沉淀池,进入接触池,再进入巴氏计量槽,最后出水;污泥的流程为:从A2/O反应池排出的剩余污泥进入集泥配水井,再由污水泵送入浓缩池, 再进入储泥池,最后外运处置。污水处理厂处理后的出水优于国家污水综合排放标准(GB8978-1996)中的一级标准。所选择的A2/O 工艺,具有良好的脱氮除磷功能。关键词:A2/O 工艺;脱氮除磷;ABSTRACT The topic of this graduate design is about the design of the sewage disposalplant in the development area of economy and techonology in Jangyin City. The technics of the plant is the Anaerobic-Anoxic-Oxic. The main task is the primary design of the plant and the shop drawing of the oxidation ditch pond. The task of the primary design isthata design book、a plan of the plant、the high drawing of the disposal of sludge and sewage; in the single disposal build design, the harvest is that the section plane drawing 、the plan and some part magnifying drawings of the Anaerobic-Anoxic-Oxic. The construction of this plant is 25000 steres per day. The process of the sewage in the plant is that the sewage runs from pumphouseto sand sinking pond, enters the pond of sedimentation tank, enters disinfection pond, then enters calculation trough ,at last lets out. The process of the sludge is that: Surplus sludge from the sedimentation tank enters concentration pond, enters digestion pong, then it is dehydrated, at last it is carried out of the plant. The outlet water of the plant meets the level one of the National SewageDischarge Standard (GB8978-1996). There is an Anaerobic-Anoxic-Oxic more than the craft of SBR in the craft of CASS. it prevents sludge from eapending,promots releasing phosphorus ,andstrengthens anti-nitration. Key words: The Anaerobic-Anoxic-Oxic; Taking off the nitrogen and thephosphorus;第一部分第1章 设计概论 设计任务本次毕业设计的主要任务是完成某经济技术开发区A2/O 工艺处理城市污水设计。工程设计内容包括:1.确定开发区排水体制,完成排水管网规划设计图;2.进行污水处理厂方案的总体设计:通过调研收集资料,确定污水处理工艺方案;进行总体布局、竖向设计、厂区管道布置、厂区道路及绿化设计;完成污水处理厂总平面及高程设计图。3.进行污水处理厂各构筑物工艺计算:包括初步设计和施工图设计(每位学生要求至少有一个构筑物的设计达到施工图深度)、设备选型,图中应有设备、材料一览表和工程量表。4.进行辅助建筑物(包括鼓风机房、泵房、加药间、脱水机房等)的设计:包括尺寸、面积、层数的确定;完成设备选型和设备管道安装图。 开发区概况及自然条件 开发区概况1.城市规划江阴临港新城位于江阴市西部,东临主城区、北枕长江、西面和南面与常州接壤,下辖“两街、两镇、一办”:夏港街道、申港街道、利港镇、璜土镇、港口办事处,总计行政区划面积188平方公里,总人口约20万人。2005年12月, 临港新城被列入无锡在“十一五”期间重点建设的五大新城之一;2006年1月,临港新城开发建设正式启动;2006年9月,临港新城被国家发改委正式核准同时被省政府批准为省级经济开发区,命名为江苏江阴临港经济开发区。江阴临港新城始终坚持“以港兴城、港以城兴、港城共荣、互动发展”的战略,全力打造苏锡常都市圈临港产业中心和江阴城市副中心。全面做好港口码头、临港产业、国际商务、现代服务、绿色生态等“五篇文章”,加快实施《临港新城培育四大千亿产业集群纲要》,推动经济与城市全面转型、同步提升。产业是城市发展的根本。依托港口,发展低碳、新材料、机械装备、现代物流四大临港特色产业,全力培育千亿级产业集群是构筑临港新城新一轮区域经济发展比较优势,打造临港经济新增长极,实现可持续发展的必由之路。2.地面水环境状况在开发区范围内长江为主水体,根据江阴市环境监测中心站编制的《江阴临港经济技术开发区环境质量报告书》,在上述7 个水体中共布设监测点19 个,并分枯水期和平水期对其进行采样监测。长江水质检测结果为:在枯水期平均值超标的(按地面水环境质量三类标准GB383888)污染物主要有生化需氧量、亚硝酸盐氮、凯式氮、总磷和大肠菌群等五项;在平水期平均值超标的主要有凯氏氮和总磷两项。其中枯水期BOD5 值最高值和平均值分别为 和5mg/L ,分别超标 倍和 倍,亚硝酸盐氮最高值和平均值分别为 和 ,分别超标 和 倍,凯式氮最高值和平均值分别为 和 ,分别超标 倍和 倍,总磷最高值和平均值分别为 和,分别超标 倍和 倍, 大肠菌群最高值和平均值分别为920000个/升和191333 个/升,分别超标91 倍和18 倍;而平水期凯式氮最高值和平均值分别为和 ,分别超标倍和倍。另外根据开发区地面水环境质量评价结果也可以看出,长江申港段污染负荷比最大,在枯水期超标的评价参数是生化需氧量、亚硝酸氮、凯式氮和总磷;在平水期超标的评价参数是总磷和凯式氮。3.开发区排水现状及规划开发区为新建区域,根据开发区排水总体规划,以采用雨污分流制的排水系统为宜。开发区范围内的雨水根据道路布置情况,依据道路控制高程分散排入现有明渠或湖汊入湖,开发区污水将汇集排入长江。目前开发区已初具规模,随着开发区的建设及工业企业的逐步开工,开发区的废水排放量将不断增多,对上述已被污染的长江申港段将进一步加大其污染负荷比,给开发区环境将带来严重的影响,也将直接影响到开发区的投资环境。另外,开发区位于长江江阴段上游,未经处理的污水直接排入长江,也将对武汉市江段的水质及饮用水源的安全造成威胁。因此,为优化投资环境,改善和提高城区生活环境质量,保证城市居民身体健康,决定修建分流制排水系统和开发区污水处理厂。 开发区的自然条件1.气象资料开发区属亚热带季风气候,全年四季分明,日照充足,雨量充沛,其气象特征如下:(1) 气温年平均气温:℃;最高气温:℃;最低气温:℃。(2)降水量年平均降水量: ;年平均降雨天数: 天。(3) 湿度年平均相对湿度:72%(4)降雪24 小时最大积雪深度:(2008年南方雪灾) 。年降雪日:一般在10 日以内(5)风全年主导风向为东北偏北,冬季以北风和东偏北为主,夏季多为东南风。年平均风速: ;最大风速: 。(6)雾日数年平均雾日数: 日;年最小雾日数:10 日。(7)蒸发量年平均蒸发量:1294mm 。 设计水量与水质⒈ 设计水量污水量标准包括生活污水和工业污水两部分。开发区的综合用水量定为625升/人.日,综合污水量按照给水量标准的80%计,则平均污水量标准为500 升/人.日。按近期规划人口10 万人计算,则该污水处理厂的近期设计污水量为:平均日25000m3/d 。2.污水水质及净化要求原污水水质:COD 320mg/L,BOD5 150mg/L,SS 200mg/L,TN 35 mg/L,NH3-N 15mg/L,TP 4 mg/L。污水经处理后应符合以下具体要求:CODCr≤60mg/L,BOD5≤20mg/L,SS≤20mg/L,TN ≤15 mg/L,NH3-N≤5mg/L,TP 1 mg/L。第2 章总体设计 排水体制在城市和工业企业中通常有生活污水、工业废水和雨水,排水系统,也就是将城镇的污水、废水和雨水系统有组织地排除与处理的工程设施。排水系统通常由排水管网和污水处理厂组成。这些污废水是用一个管渠系统还是用两个、三个管渠系统来排,构成了不同的排除方式,称之为排水系统的体制。 合流制排水系统目前我国大多数城市排水体制为合流制,合流制排水系统就是将生活污水、工业废水和雨水用一个管渠系统汇集排除的系统。这种体制有下面两种方式:1.合流制这种方式是将管渠系统分成若干排出口,将混合污水不经任何处理直接就近排八水体。这是一种合流制排水方式,国内外许多老城市几乎者是采用这种简单的排水方式。在过去,工业尚不发达,人口少,污水相对不大,采取水体的自净作用,这种排水体制被长期采用。但是在当今,科技的发展,人口增加,使污水不断增加,水质也日趋复杂,从环保卫生上来看,合流制是水环境污染的主要原因,所以在目前情况就不宜再采用这种排水体制。 截流式合流制这种方式就是在江河岸边修建截流干管,并在合流干管与截流干管交汇设置溢流井。晴天时,混合污水全部由截流干管送至污水处理厂处理后排放;雨天时,当混合水是超过截流干管输水能力后,其超出部分通过溢流并泄八水体。这种体制对带有较多悬浮物的初期雨水和污水都进行处理,对保护水体是有利的,但周期性地给水体带来一定程度的污染,很明显,同为合流制,它又前者优越。这种方式,对一些旧城合流制排水系统改造是可以考虑加以采用的。 分流制排水系统当生活污水、工业废水和雨水用两个或两个以上排水管渠排除时,称为分流制排水系统。其中排除生活污水,工业废水的系统称为污水排水系统;排除雨水的系统称为雨水排水系统。这种体制又有两种方式: 1.完全分流制将城市生活污水及工业废水排到污水系统和雨水排入到雨水系统的体制为分流制。污水排至污水处理厂进行处理,雨水直接排入水体,对于新建城市、新的开发区和新建住宅小区,大都采用这种形式,分流制系统是把城市污水全部送到污水处理厂处理后排放水体,对环保卫生及防止水体污染方面无疑是比较好的排水体制。2.不完全分流制只建污水排水系统,未建雨水排水系统,雨水沿着地面、道路边沟和明渠泄入水体。对于常年少雨、气候干燥的城市可采用这种制。 排水体制的比较排水体制的选择直接影响到对环境的污染。直泄式合流制是不经任何处理把混合污水排入水体,其对水体污染的严重性是不言而喻的,截流式合流制能将晴天时全部生活和工业废水及降雨时较脏的初期雨水截走,送往污水处理厂,这对保护水体是有利的,但在暴雨时,仍有部分混合污水通过溢流井进入水体,造成污染。分流制排水系统,将城市污水全部送至污水厂处理,但初期雨水未经处理直接排入水体,是其不足之处。一般情况下,分流制比截流式合流制在防止水体污染方面更为优越,而且较灵活,较易适应发展的需要,因此应用较广泛。从基建投资方面来看,合流制只需一套管渠系统,其断面尺寸与完全分流制的雨水管渠基本相同,虽然合流制在污水泵站及处理厂规模上要大一些,造价要高一些,但在总体造价还是低于完全分流制,大约要低20-40%。不完全分流制由于没有雨水排水系统,所以其投资最省,施工期最短,发挥效益也快,所以对于一般新建地区,地形坡度比较好,雨水又能沿坡度流入水体,为节约初期投资,可先采用不完全分流制,以后随着建设的发展,再逐步造雨水管渠。从维护管理方面来看,合流制管渠维护管理较简单,对于管渠中的沉积物也可利用雨天的大流是来冲刷,但污水泵站、处理厂因晴雨天的排水量变化幅度较大,增加了运行管理上复杂性。相比之下分流制污水管渠和污水处理厂,流量变化不大,不致产生沉淀物,有利于污水处理厂和管渠的运行管理。 排水体制选择选择排水体制时,应当根据当地的实际条件和环保要求,通过技术经济比较来确定。1.新建城市(1)对于新建城市,当地形有利,在城市发展初期,可采用不完全分流制。人卫生角度上看,虽然雨水沿着地面流动,会带入一些污染物质进入水体,但由于最肮脏的生活污水已用污水管渠收集并加以处理,因此不致于对环境卫生产生很大影响;从经济上看,由于只建污水管渠,造价可大为降低,这在城市发展初期具有很大经济意义;从技术上看,由于已预留雨水管渠的位置,它可随城市发展逐步增设雨水管渠,成为较理想的完全分流制。(2)对于建设水平要求较高且面积较大的开发区城市,应采用完全分流制。2.旧城改造和扩建旧城排水系统的改造和扩建,应在原排水体制的基础上加以考虑。旧城排水系统,一般均为没有污水处理厂的合流制排水系统,污水就近排入水体,没有预留埋设其他管线的地方。因此要将它改造为完全分流制,这在经济上要花费一笔可观的费用,在技术上也十分困难,往往难以实现。且附近水体又缺乏足够的自净能力时,才可考虑改建成其他体制。3.因此,对某城区排水系统的改造和扩建工程中,采用具有截流制合流制排水系统为宜,截流后污水排入到污水处理厂进行处理。总之,影响排水体制的因素较多,我们应立足于本地实际条件,同时考虑污水管排水能力发展的余地,使城市排水体制更加合理完善。根据该经济开发区的较为平坦的地势因素,故管道敷设主要以管长最短为原则,沿街道敷设,一起送入污水处理厂处理后排入长江。 污水处理厂设计规模污水量标准包括生活污水和工业污水两部分。开发区的综合用水量定为625 升/人.日,综合污水量按照给水量标准的80%计,则平均污水量标准为500 升/ 人.日。按近期规划人口10 万人计算,则该污水处理厂的近期设计污水量为:平均日25000m3/d。第3 章污水处理厂设计 污水处理厂址选择污水厂厂址选择应遵循下列各项原则1、应与选定的工艺相适应2、尽量少占农田3、应位于水源下游和夏季主导风向下风向4、应考虑便于运输5、充分利用地形本开发区在总体规划、专业规划及开发区建设中,已按自然地形,用地规划预留了污水处理厂位置。 污水污泥处理工艺选择 水质根据《江阴临港新城经济开发区污水处理厂可行性研究报告》及江阴临港新城经济技术开发区委员会“污水处理厂可行性研究报告评审会专家组意见”,开发区管委会参照类似地区的污水水质及国家《污水综合排放标准》(GB18918-2002) 提出污水处理厂进、出水水质指标列于表 污水处理厂进、出水水质指标单位:毫克/升 表序号 项目 原污水质 出水水质1 BOD5 160 202 CODCr 400 603 SS 125 204 TN 45 205 NH3—N 28 8(15)6 TP 5 污水、污泥处理工艺选择1. 处理工艺流程选择应考虑的因素污水处理厂的工艺流程系指在保证处理水达到所要求的处理程度的前提下,所采用的污水处理技术各单元的有机组合。在选定处理工艺流程的同时,还需要考虑各处理单元构筑物的形式,两者互为制约,互为影响。污水处理工艺流程的选定,主要以下列各项因素作为依据。① 污水的处理程度② 工程造价与运行费用③ 当地的各项条件④ 原污水的水量与污水流入工程该污水处理厂日处理能力约万吨,属于中小规模的污水处理厂。按《城市污水处理和污染防治技术政策》要求推荐,20万t/d规模大型污水厂一般采用常规活性污泥法工艺,10-20万t/d污水厂可以采用常规活性污泥法、氧化沟、SBR、AB法等工艺,小型污水厂还可以采用生物滤池、水解好氧法工艺等。对脱磷脱氮有要求的城市,应采用二级强化处理,如A2 /O工艺,A/O工艺,SBR及其改良工艺,氧化沟工艺,以及水解好氧工艺,生物滤池工艺等。A2O工艺污水处理量:25000m3/d氧化沟工艺污水处理量:3000m3/dSBR工艺污水处理量:5000m3/d2.适合于中小型污水处理厂的除磷脱氮工艺该污水处理厂要求对原水中的氮、磷有比较好的去除,应采用二级强化处理。根据《城市污水处理和污染防治技术政策》推荐,以及国内外工程实例和丰富的经验,比较成熟的适合中小规模具有除磷、脱氮的工艺有:AA /O 工艺,A/O 工艺,SBR及其改良工艺,氧化沟及其改良工艺。A/O工艺、AA/O工艺、各种氧化沟工艺、SBR工艺这些从活性污泥法派生出来的工艺都可以实现除碳、除氮、除磷三种流程的组合,都是比较实用的除磷脱氮工艺。一、A2O处理工艺 (1)A2/O 处理工艺是Anaerobic-Anoxic-Oxic 的英文缩写,它是厌氧-缺氧-好氧生物脱氮除磷工艺的简称,A2/O 工艺是在厌氧-好氧除磷工艺的基础上开发出来的,该工艺同时具有脱氮除磷的功能。(2)A2/O 工艺的特点:A:厌氧、缺氧、好氧三种不同的环境条件和不同种类的微生物菌群的有机配合,能同时具有去除有机物、脱氮除磷功能;B:在同时脱氮除磷去除有机物的工艺中,该工艺流程最为简单,总的水力停留时间也少于同类其它工艺。C:在厌氧-缺氧-好氧交替运行下,丝状菌不会大量繁殖,SVI 一般小于100,不会发生污泥膨胀。D:污泥中含磷量高,一般为以上。由于该设计对脱氮除磷有要求故选取二级强化处理,并且污水处理量25000m3/d。所以A2O工艺符合要求。因为这种工艺具有较好的除P脱N功能;具有改善污泥沉降性能的作用的能力,减少的污泥排放量;具有提高对难降解生物有机物去除效果,运行效果稳定;技术先进成熟,运行稳妥可靠;管理维护简单,运行费用低;沼气可回收利用;国内工程实例多,容易获得工程设计和管理经验技术先进成熟,运行稳妥可靠,最为重要的是该工艺总水力停留时间少于其他同类工艺,节省基建费用,占地面积相对较小,在市场经济的形势下,寸土寸金,该工艺无疑具有非常大的吸引力。 法同步脱氮除磷工艺的原理:A2/O 分为三大部分,分别为厌氧、缺氧、好氧区。原污水从进水井内首先进入厌氧区,同步进入的还有从沉淀池排出的含磷回流污泥,本反应器的主要功能是释放磷,同时部分有机物进行氨化。污水经过第一厌氧反应器进入缺氧反应器,本反应器的首要功能是脱氮,硝态氮是通过内循环由好氧反应器送来的,循环的混合液量较大,一般为2Q(Q——原污水流量)。混合液从缺氧反应器进入好氧反应器——曝气器,这一反应器单元是多功能的,去触BOD ,硝化和吸收磷等项反应都在本反应器内进行。这三项反应都是重要的,混合液中含有NO3-N ,污泥中含有过剩的磷,而污水中的BOD 则得到去除。流量为2Q的混合液从这里回流缺氧反应器。选定核心构筑物后,本设计的工艺流程也就相应确定了。 主要生产构筑物工艺设计 进水泵房污水进水泵房由格栅间、泵房组成(泵房配电间设于离泵房不远的地方,具体布置见污水厂平面总体布置图,另外厂内另设有集中变配电间、中控室)。⑴ 格栅间平面尺寸:长×宽= 米× 米,地下深 米,为钢筋砼结构,格栅间内设三道进口粗格栅,两道为机械格栅,另一道为人工辅助格栅。机械格栅宽 米,高 米,栅条间隙20 毫米,安装倾角600 ,机械除渣。人工格栅(在机械格栅检修时做应急用)宽 米,高 米,栅条间隙、安装倾角均同机械格栅。⑵ 泵房采用半地下室钢筋砼结构,平面尺寸:长× 宽= 米× 米,地下埋深 米,采用立式污水泵抽升污水,泵房内设五台型号为250QW700—11—37 的立式污水泵(四用一备)。单泵流量为690 米3/时,扬程为 米,转速970 转/分,电机功率37 千瓦。每台泵出水管上设微阻缓闭止回阀,起吊设备采用电动单梁起重机,最大起重量为2 吨。 细格栅和沉砂池共设两道进口细格栅,安装在出水井与沉砂池的连接渠道上,用于去除进厂污水中较大的漂浮物和悬浮物,以保证后续处理工艺的安全运行。细格栅(一期)分两组设置,每组设2 道进口机械弧形细格栅(旋转角为90。)及1 道人工应急格栅(国产),渠宽为1.3m,栅隙宽为10mm,最大过栅流速为/s 。格栅的运行由格栅前、后水位差自动控制。栅渣由设于平台面以下的国产无轴螺旋输送器输出后外运处置。沉砂池采用了旋流式沉砂池(分两组设2 池,型号旋流式沉砂池Ⅱ7),单池直径为、池深为,采用气提排砂,在排砂之前有一气洗过程,这使得排出的砂含有机物较少,有利于污水的后续生物处理及泥砂的处置。由两座沉砂池排出的泥砂经2 台国产的砂水分离器处理后外运处置。 A2/O 池A2/O 生物池分两组(共2 座),污泥负荷为0.12kgBODs/(kgMLSS·d),污泥浓度为 g/L,单池平面尺寸为×(包括隔墙厚度),池深为 m(有效水深为 m),每池分三区即厌氧区、缺氧区及好氧区,厌氧区设4台、缺氧区设4 台进口潜水搅拌机,单台搅拌机的功率为 kW。好氧区设有2938 个进口膜式微孔曝气器,曝气量为1~3m3 /( h × 个)。每池设有3 根进气总管,每根总管设有1 个进口电动空气调节蝶阀(用于调节供氧量)。A2/O 工艺需有大量的混合液回流(一般为处理水量的2~4 倍),这使得其能耗较高。为此,在设计时结合了循环流式生物池的特点,采用了类似氧化沟循环流式水力特征的池型,省去了混合液回流以降低能耗,同时在该池中独辟厌氧区除磷及设置前置反硝化区脱氮等有别于常规氧化沟的池体结构,充氧方式采用高效的鼓风微孔曝气、智能化的控制管理,这大大提高了氧的利用率,在确保常规二级生物处理效果的同时,经济有效地去除了氮和磷。该系统较常规A2/O 工艺降低能耗约0.045(kW·h)/m3。

给排水论文英文参考文献

MECHANICAL PRELIMINARY DESIGN REPORT STADIUM 1.给排水设计 饮用水和污水 Design Water and sewage water .设计基础 - 甲方提供的设计任务书和市政管网综合图 - 建筑专业提供的条件图 - 国家现行的设计规范及有关规定设计简章 .Design bases Design Brief and Municipal integrated network drawing offered by the client. Condition drawings from architectural discipline. Current national design codes and related stipulations 2. 给水系统 通过一根DN200的进水管将水引入.水表安装在进水管上,离红线1米处.供水管在红线内连成环路管网,并接到供应楼的消防水池和给排水水池.由环路管网向必需的室外消火栓和绿化带的喷淋器供水. 2. Water supply system For water supply of this project, DN200 water intake pipes are led in. Water meters are installed on the intake pipes m away from the red line. The water supply pipes are connected into loop networks in the red line and then led to the fire pool and sanitary water pool in the supply buildings respectively. Necessary number of outdoor hydrants and sprinklers for green area will be provided on the loop networks. 设计范围 包括红线内的饮用水,污水,雨水,建筑消防. Design scope Design scope of this project includes water, sewage water, rainwater, fire-protection in the building, and water and sewage water within the red line. 给排水水池与消防水池分开,容量为100m3 .体操馆供水管埋地敷设. Sanitary water pool is separated from fire water pool, volume of sanitary water pool is 100m3. Water supply pipes for the stadium will be laid in the earth. 3.用水量标准 - 体育馆: 15升/顾客·日 K= - 宾馆: 150升/人·日 K= - 餐厅: 50升/顾客·日 K= - 工作人员: 25升/人·日 K= - 地面冲洗用水: 3升/m2日 - 冷却塔补水量:按用水量的2%计 - 未预见水量: 按日用水量20%计 - 消防用水: 消火栓:室内40升/秒,室外30升/秒,火灾延续时间为3小时; 自动喷洒按22升/秒,火灾延续时间为1小时 卷帘水幕用水升/秒·米,火灾延续时间为3小时; Water consumption standard - Stadium: 15L/visitor·day K= - Hotel: 150L/visitor·day K= - Restaurant: 50L/customer·day K= - Staff 25L/person·day K= - Floor cleaning: 3L/m2·day Make-up water for cooling tower: 2% of the actual cold water consumption. Unforeseen water consumption: 20% of the daily water consumption. Water for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration time is 3h; Sprinkler: 22L/s, fire duration time is 1h; Drencher for rolling shutter: ·m, fire duration time is 3h; 在适当的位置设置饮用水机,在主进口为残障人设置两个饮用水机.为此饮用水系统安装循环泵.机房 设在地下室的水除了机房.当饮用水机不被使用时,应排空,以免水质腐败. 在客房和餐厅内设置电热水器,同时亦为热水供应设置循环泵. 在更衣间旁设置电热水器,为淋浴和洗盥供应热水. 为楼板清洁安装一定数量的水龙头. Some suitable places are supplied with portable water drinking units, two drinking units for disable people are provided at main entrances, for this portable water system, circulating pumps are adopted, the equipment room is located in water treatment center in the basement. When there is no use, portable water will be drained completely to avoid deterioration. Electric water heaters are installed in guest rooms and restaurant, also hot water circulating pumps will be provided for supplying hot water. Electric water heaters are installed near the changing and clothing rooms for supplying hot water for shower and washing. Certain number of water taps are installed for floor-cleaning. 4.用水量 最大日用水量:日 最大时用水量:220m3/时 Water consumption demand Maximum daily water consumption: Maximum hourly water consumption: 220m3/hour 却循环系统 冷却水循环系统采用机械循环系统.总冷却水用量为460m3/h.在供应楼顶设置三台超低噪音冷却塔(230 m3/h, 2x 115 m3/h).进水温度37Co,出水温度32Co .补充水量 9,6 m3/h.补充水由市政供水网直接提供. Cooling water circulation system There are cooling water circulation system in this project, cooling water for the refrigerators adopts mechanical circulation system. Total water consumption of cooling towers is 460m3/h. On roof of the supply building there are 3 ultra-low noise cooling towers (230 m3/h, 2x 115 m3/h), inlet temperature of 37Co, outlet temperature of 32Co, with make-up water of 9,6 m3/h. Make-up water of the cooling towers will be supplied directly by the municipal network. 在消防泵房内有消火栓泵(一个运行,一个备用),喷淋泵(一个运行,一个备用),卷帘雨淋泵(一个运行,一个备用).用于地下车库的泡沫喷淋设备,如报警阀,泡沫压缩罐,化学药剂泵安装在消防设备中心. 消防水箱和消防稳压装置分别安装在车库的四面墙. In the fire water pump room, there are hydrant pumps (one operation, one standby), sprinkler pumps (one operation, one standby) and rolling shutter drencher pumps (one operation, one standby). Fire equipment, which are used for the foam sprinkler system in underground garage, such as fire alarm valves, foam concentrated tank and chemical dosing pump, etc. are provided in fire equipment centers. Four fire water tanks and fire protection stabilized pressure devices are respectively located at four sides next to the garages. 消防用水 消火栓:室内按40升/秒,室外按30升/秒,火灾延续时间按3个小时计 自动喷洒按22升/秒,火灾延续时间按1小时计 卷帘水幕用水量 升/秒·米,火灾延续时间按3个小时计 消火栓:室内,室外用水量皆为756m3; 自动喷洒用水量为 m3; 卷帘水幕用水量为 270m3; 一次火灾用水量为; Water for fire protection Water consumption standard for fire protection Hydrant: 40L/s indoor, 30L/s outdoor, fire duration is 3h Sprinkler: 22L/s, fire duration is 1h Drencher for rolling shutter: ·m, fire duration is 3h Water consumption for fire protection Hydrant: indoor and outdoor water consumptions are 756m3 respectively Sprinkler: m3 Drencher for rolling shutter: 270m3 Water consumption for one fire: m3 消火栓的布置 在整个建筑物内沿墙,沿柱,沿走廊,风塔上及楼梯附近设有必要数量的室内消火栓,消火栓间距小于30米.消火栓管网水平,竖向皆成环状布置,消火栓箱内配有DN65消火栓一支,25米衬胶水龙带一条,φ19毫米喷咀水枪一支,并配消防卷盘(DN25消火栓一支,30米胶管,φ9毫米喷咀水枪一支)且设有可直接启动消火栓泵的按钮;在室内消火栓箱下设有磷酸铵盐手提式灭火器箱.室内消火栓系统在室外设有三组水泵接合器. Hydrant arrangement Necessary number of hydrants are installed indoors along the wall, columns, corridors, and staircases, at intervals of less than 30m. Hydrant networks are connected as a loop both horizontally and vertically. Inside each hydrant box, a DN65 hydrant, a 25m long rubber lined hose, a water nozzle of φ19mm, hose reel (a DN25 hydrant, a 30m long rubber lined hose and a water nozzle ofφ9mm), and a direct starting button for the hydrant pump are provided. Under each indoor hydrant box, a portable ammonium phosphate powder extinguisher box is installed. There are three sets of pump adopters being installed outdoors for the indoor hydrant system. 消防系统 防水泵房及消防水池 供水管DN200在红线内连成环路管网,管网上安装 一定数量的消火栓.两根DN200供水管分别引入供应楼内两个消防泵房内的消防水池.消防水池总容量不应小于4000m3, 每个为. Fire protection system Water pump room and water pool for fire protection The lead-in pipes (DN200) are connected as a loop inside the red line, on the loop, certain number of hydrants are water supply pipes (DN200) are led into the fire water pools at each fire water pump room in supplybuilding. In consideration of the importance of the project, the volume of the fire water pools should be not less than 4000m3, each is . 自动喷淋系统 自动喷淋系统安装在全建筑范围,除了室外和高于10 米的房间.喷淋泵安装在地下的消防泵房内.报警阀设置在地下的消防泵房内和中间的消防设备中心内,水流显示器设在每个防火分区内. Sprinkler system Sprinkler systems will be provided inside the whole building except outside areas and roomshigher than 10m, with sprinkler pumps installed in the underground fire water pump rooms. Alarming valves installed in underground fire water pump rooms and four fire equipment centers in the middle, water flow indicators are installed by fire compartments. 除了安装一个封闭喷淋系统,将为地下车库设置一个泡沫喷淋系统.餐厅内安装93oC启动的自动喷淋头,但在其它房间,仅安装93oC启动的普通和快速反应自动喷淋头.三组泵接合器安装在室外. Besides an enclosed sprinkler system, a foam sprinkler system composed of a proportioning mixer and a foam concentrated tank is provided for the underground garage. Sprinkler actuated at 93oC are provided in the restaurants, but in other rooms, only ordinary sprinklers and fast response sprinklers actuated at 68oC are provided. Three sets of pump adaptors for this system will be installed outdoors. 排水系统 为排水系统设置污水主立管和特别垂直排气管.排气管与污水管在每层连接,污水排出体操馆.餐厅的污水首先在油脂分离池中处理,然后排入室外排水网.给排水污水将被在化粪池收集和处理,然后排入市政排水管网.化粪池在输送区旁.最大天排水量为870m3/天. 9. Drainage system Main vertical sewage pipes and special vertical vent pipes are provided for the drainage system. The vent pipes are connected with sewage pipe at each floor; sewage water is drained out of stadium. Sewage water in the restaurants and garage are treated in the grease and oil separation tank, and then discharged into the outdoor drainage networks. Sanitary sewage water is collected and treated in the septic tank, then drained into the municipal drainage. The septic tanks are located besides the deliverycircle. Maximum daily drainage amount is 870m3/day. 卷帘水幕系统 地下车库设置有卷帘水幕系统.水幕泵安装在消防水泵房内,采用开式雨淋头,电动或手动控制.十组泵接合器安装在室外 Drencher system for rolling shutters Rolling shutter protected by drenchers are provided for the underground garage, the drencher pumps are installed in the fire water pump rooms, open drencher heads are selected, and are controlled both by electrically and manually. Ten pump adapters will be installed outdoors for this system. 地下室内污水设有污水坑,废水设有废水坑,生活污水,废水经潜污泵提升排至室外排水管网,潜污泵的启停皆由磁性浮球控制器的控制. 地下汽车库废水设有废水坑,废水经潜污泵提升排至室外,经隔油池处理后排入室外雨水管网. There are cesspits for sewage water and wastewater pits for wastewater in the basement, the sewage and wastewater is sucked up and drained to the outdoor drainage networks by submerged sewage pumps. Operation of the pumps is controlled by the magnetic floating ball controllers. Wastewater pits are provided for the underground garage, wastewater is sucked up and drained to outdoor oil separation tank by submerged sewage pumps, after treated, wastewater is drained to the outdoors rainwater networks. 在柴油发电机房,变配电房和通讯设备机房设低压二氧化碳气体灭火系统. Low pressure CO2 extinguisher systems are provided in diesel generator rooms, transformer substations and telecommunication equipment rooms. 在本建筑内按"建筑灭火器配置设计规范"在每个消火栓箱下设手提式灭火器箱,箱内设有必要数量的磷酸铵盐手提式灭火器. According to the Code for Design of Extinguisher Disposition in Buildings, portable fire extinguisher box, in which there are necessary number of portable ammonium phosphate powder extinguishers, will be installed under every hydrant box. 在每个消防电梯井底旁设有消防排水坑,废水经潜污泵提升排至室外. Fire water drain pit is provided at side of bottom of each fire elevator well, waste water will be sucked up and drained out by the pumps. 雨水系统 雨水排水屋顶采用压力流排水. 雨水设计重现期按P=10年计算,降雨历时为5分钟,暴雨强度公式按Q=(1+)/(t+)计算. 沿柱在屋面设置雨水沟.雨水通过雨水沟收集,然后进入雨水头和下排管,然后到室外雨水观察井. 10. Rainwater system Pressurized drainage system is adopted for roof rainwater drainage system. Here, return period P=10 years, rainfall duration is 5 minutes, stormwater amount is calculated by the following formula: Q=(1+)/(t+) Rainwater gutters are provided on roof along columns, skylight. Rainwater is collected in the gutter, then to rainwater heads and downpipes, and to the outdoors rainwater inspection wells. 11.管材 - 生活给水管,冷却塔补水管采用铜管,氩弧焊接. - 直饮水管采用不锈管. - 消火栓管,冷却循环管,水幕管,水泵吸水管采用焊接钢管,焊接. - 自动喷洒水管,雨淋水管采用热镀锌钢管,丝扣连接或卡压连接. -二氧化碳管采用无缝钢管焊接. - 地下车库泡沫喷淋水管采用不锈钢管,卡压连接. Pipe material Copper pipes connected by argon arc welding are adopted for the sanitary water pipes, make-up water pipes for cooling towers. Stainless stell pipes are adopted for portable water pipes. Welded steel pipes connected by welding are selected for hydrant pipes, cooling circulating pipes, drencher pipes, pump suction pipes. Hot-galvanized steel pipes connected by threads or compression-seizing are selected for sprinkler and deluge sprinler pipes. Seamless steel pipes connected by welding are selected for CO2 pipes. Stainless steel pipes connected by pressed clamp is selected for the pipes of foam sprinklers in the underground garage. 当雨水两超出雨水沟设计量时,雨水可沿屋檐自由排放.雨水被收集,然后排入市政集水池. When the amount of rainwater is more than the design value of the gutters, water is discharged naturally along the eaves. Rainwater is collected, and then drained to the municipal catch basins. 围绕体育馆的循环池将用于喷洒运动场和作为室外绿化带的储水池. 此池将作为一个循环过滤设施,可容水约 m . 喷洒压力设备和其它必须的过滤设备安装在供应楼里. The circular senic pool surround stadium will be used for spraying sportsfield and as reservoir for outdoor greening. The pool will be used as a circular filtering facility and will be adopted with a water volume of about m . The spray water pressurizing equipment as well as further necessary filtering equipment will be adopted in the supply building. 制冷 Cooling 冷源: 空调冷负荷(估算): 本工程建筑面积共平方米,包括观众区,休息室,更衣室,小会议室,餐厅,办公室和其它附属房.空调设计日峰值冷负荷为,设计日总冷负荷为3 kW. Refrigerating source Cooling load of air conditioning system Total floor area for this building is 50,000sqm, which includes spectator areas, lounges, Clothing and changing rooms small meeting rooms, restaurant, office and other auxiliary rooms. Designed dayly peak cooling load is 2,4MW, designed total dayly cooling load is 3kW. 每台1200kW制冷机配一台 流量为206m3/h离心泵.各配一台备用泵 一次泵采用压差旁路控制. 通过埋地敷管,向游泳体操馆供应冷冻水. A centrifugal pump with a flow rate of 103m3/h is provided for each 1200kW chiller. One operation pump with a standby corresponds to one chiller. Pressure difference branch control is adopted for primary pump Via earth laid pipes from supply building to gymnasium chilled water supply will be deliverded. 冷源的选择: 根据建筑的实际情况,3台制冷机将安装在供应楼内的冷冻机房.设计容量为4800kW. 为了实现能量的效率化使用,设计方案为,1台制冷机的出力为总设计容量的50%.而另2 台.每台出力为总设计容量的25%. 冷冻水系统的主要设备包括3台电动制冷机,一级冷冻泵,二级冷冻泵,自动控制阀等等.冷冻水的供/回水温度为-7/ 12°C. Selection of refrigerating source According to the real condition of the building, 3 chillers are located in the refrigerating plant rooms in the supply building, designed capacity is 2400kW. For actuing in an energy efficient way one chiller about 50% of total capacity ( kW) and two chillers with 25% of total (600 kW each)capacity each are adopted. Main equipment of chilled water system includes 3 electrical chiller, primary cool water pump, secondary chilled water pump and automatic controlled valve, etc. supply/return temperature of the chiller is-7/ 12°C. 二次泵系统:根据使用功能,各制冷机房又分成不同的循环支路. 二次泵采用变频调速控制.根据负荷侧供回水管的压差,控制水泵的转速. 二次泵循环支路的管道采用异程式. Secondary pump system: Each refrigerating plant room is subdivided into different circulation branch loops according to use functions. Variable-frequency speed-regulating control is adopted for secondary pumps. The rotating speed of a water pump is controlled according to the pressure difference between water supply and return pipes. Direct return system is adopted for the pipes of circulating branch of secondary pumps 空调冷冻水系统 由于本工程占地面积大,功能复杂,有连续使用,也有间歇使用,为了达到运行灵活,节能的目的,空调冷冻水系统采用两管制二次泵系统. Chilled water system Due to the large occupied area of this project, the complicated functions and the combination of continuous utilization and intermittent utilization, in order to accomplish the purpose of flexible operation and energy saving, the chilled water system is of two-pipe secondary pump system. 管材: 水管采用焊接钢管及无缝钢管. 本工程的风管除土建风道外,均采用镀锌铁皮咬口制作.每节风管之间用法兰连接. Pipe and duct materials The water pipes adopt welded steel pipes and seamless steel pipes. Air ducts for this project are made of galvanized sheet steel by seaming except ducts by civil construction. Air ducts are connected together by flanges. 一次泵系统: 供应楼冷冻机房 2400kW制冷机配一台离心泵, 流量为412m3/h.配一台备用泵. Primary pump system: Chiller room supply building A centrifugal pump with a flow rate of 412m3/h is provided for 1200kW chiller. One operation pump with a standby corresponds to one chiller. 保温材料: 空调供,回水管,冷凝水管采用酚醛管壳保温. 空调送,回风管以及处理后的新风管采用外贴铝箔的离心玻璃棉板保温. - 管道穿防火墙的空隙处采用岩棉材料等非燃材料填充. Thermal materials phenolic pipes are adopted for thermal insulation of water supply and return pipes for air conditioning, as well as air-conditioning condensate pipes. Aluminum foil faced glass fiber boards are adopted for thermal insulation of air-conditioning air supply and return ducts as well as fresh air ducts after chillers. Non-flammable material will be selected to fill the interspace in the fire protection wall where the ducts go through. 消声与隔振: 冷水机组,水泵等设备采用减振台座,弹簧减振器或橡胶减振垫减振降噪. 在空调机组,新风机组,通风机的进出口采用涂胶帆布软管连接. - 水泵进出水管上采用可曲挠橡胶接头,使设备振动与配管隔离. Noise reduction and vibration isolation Shock absorption bases, spring shock absorbers on rubber shock absorption pads are adopted for equipment, such as water chiller units, pumps, etc to reduce vibration and lower noise. Flexible rubber-coated canvas hoses are adopted far connections of inlets and outlets of air-conditioning units, fresh air handling units and ventilators. Flexible rubber couplings are adopted for the water intake and delivery pipes of the pumps to isolate equipment vibration from their pipes. 空调和通风系统 Air Conditioning and Ventilation Systems 方案设计范围 Scope of schematic design 空调设计 Air Conditioning Design 在体育馆内,一些区域设置空调系统.这些区域划分为: 西侧地下二层的贵宾休息室 东侧地下二层酒店门廊 地下一层的输送区,技术机房,运动员更衣间,医务服务,热身区,裁判区,健身中心,酒店大堂,会议室,厨房,特许区和贵宾大堂混合区. 首层的酒店大堂,酒店区,贵宾门廊,急救 In the stadium, in some ranges air conditioning systems are used. These ranges subdivide themselves as follows: VIP – Lobby in West of levelel -2 Hotel lobby in the east of level –2 Delivary Circle, technical Plantrooms, Changingrooms for the athletes, Medical Service and warm up area, Judges Area, Fitness Center, Hotel Lobby, Conferenz, Kitchen and Concession, Vip lobby- Mixed Zone in level -1 Hotel lobby, Hotel area, Vip lobby, Vip Area, First aid in 0

英文参考文献标准格式

参考文献是学术论文的重要组成部分,它的作用众所周知,在此不再赘述。参考文献是英语论文的重要组成部分,也是编辑加工和重要内容。为帮助大家顺利完成学术论文的撰写,我为大家介绍英语论文参考文献格式要求,欢迎阅读。

学位论文参考文献的.格式

丨 期刊

期刊作者.题名[J].刊名,出版年,卷(期):起止页码

周庆荣,张泽廷,朱美文,等.固体溶质在含夹带剂超临界流体中的溶解度[J].化工学报,1995,46(3):317 323

Dobbs J M, WongJ M. Modification of supercritical fluid phasebehavior using polorcoselvent[J]. Ind Eng Chem Res, 1987,26:56

刘仲能,金文清.合成医药中间体4-甲基咪唑的研究[J].精细化工,(2):103-105

Mesquita A C,Mori M N, Vieira J M, et al . Vinyl acetatepolymerization by ionizingradiation[J].Radiation Physics and Chemistry,2002, 63:465

丨 专著

专著作者.书名[M].版本(第一版不著录).出版地:出版者,出版年.起止页码

蒋挺大.亮聚糖[M].北京:化学工业出版社,

Kortun Spectroscopy[M]. New York: Spring-Verlag,1969

丨 论文集

论文集作者.题名[C].编者.论文集名.出版地:出版者,出版年.起止页码

郭宏,王熊,刘宗林.膜分离技术在大豆分离蛋白生产中综合利用的研究[C].余立新.第三届全国膜和膜过程学术报告会议论文集.北京:高教出版社,

Eiben A E,vander Hauw J 3-SAT with adaptive geneticalgorithms [C].Proc 4th IEEEConfEvolutionary Press,

丨 学位论文

学位论文作者.题名[D].保存地点:保存单位,年份

陈金梅.氟石膏生产早强快硬水泥的试验研究(D).西安:西安建筑科学大学,2000

ChrisstoffelsL A J . Carrier-facilitated transport as a mechanistic tool insupramolecular chemistry[D].The Netherland:

丨 专利文献

专利文献题名[P].国别,专利文献种类,专利号.出版日期

仲前昌夫, 佐藤寿昭. 感光性树脂[ P ]. 日本, 特开平

Hasegawa,Toshiyuki, Yoshida,et Coating composition[P].EP

Yamaguchi K,Hayashi A. Plant growth promotor and productionthereof [P].Jpn,

丨 技术标准文献

标准标准编号,标准名称[S]

ISO 1210-1982,塑料 小试样接触火焰法测定塑料燃烧性[S]

GB 2410-80,透明塑料透光率及雾度实验方法[S]

丨 报纸

报纸作者.题名[N].报纸名,出版日期(版次)

陈志平.减灾设计研究新动态[N].科技日报,1997-12-12(5)

丨 报告

报告作者.题名[R].保存地点:年份

中国机械工程学会.密相气力输送技术[R].北京:1996

丨 电子文献

电子文献作者.题名[电子文献及载体类型标识].文献出处,日期

万锦柔.中国大学学报论文文摘(1983-1993)[DB/CD].北京:中国百科全书出版社,1996

文献类型及其标识

根据GB3469 规定:

①期刊[J]

②专著[M]

③论文集[C]

④学位论文[D]

⑤专利[P]

⑥标准[S]

⑦报纸[N]

⑧技术报告[R]

电子文献载体类型用双字母标识,例如:

①磁带[MT]

②磁盘[DK]

③光盘[CD]

④联机网络[OL]

①联机网上数据库[DB/OL]

②磁带数据库[DB/MT]

③光盘图书[M/CD]

④磁盘软件[CP/DK]

⑤网上期刊[J/OL]

⑥网上电子公告[EB/OL]

英文文献采用 APA格式

丨 单一作者著作的书籍:

姓,名字首字母.(年). 书名(斜体). 出版社所在城市:出版社.

Sheril, R. D.(1956). The terrifying future: Contemplating color television. San Diego:Halstead.

丨 两位作者以上合著的书籍:

姓,名字首字母., & 姓,名字首字母.(年). 书名(斜体). 出版社所在城市:出版社.

Smith, J., & Peter, Q. (1992).Hairball: An intensive peek behind the surface of an enigma. Hamilton, ON:McMaster University Press.

丨 文集中的文章:

Mcdonalds, A.(1993). Practical methods for the apprehension and sustained containment ofsupernatural entities. In G. L. Yeager (Ed.), Paranormal and occult studies:Case studies in application (pp. 42–64). London: OtherWorld Books.

丨 期刊中的文章(非连续页码):

Crackton, P.(1987). The Loonie: God's long-awaited gift to colourful pocket change?Canadian Change, 64(7), 34–37.

丨期刊中的文章(连续页码):

姓,名字首字母.(年). 题目. 期刊名(斜体). 第几期,页码.

Rottweiler, F. T.,& Beauchemin, J. L. (1987). Detroit and Narnia: Two foes on the brink ofdestruction. Canadian/American Studies Journal, 54, 66–146.

丨月刊杂志中的文章:

Henry, W. A., III.(1990, April 9). Making the grade in today's schools. Time, 135, 28-31.

英文论文参考文献格式如下:

一、学术论文英文参考文献标注格式

按照现行规定,学术期刊中论文参考文献的标注采用顺序编码制,即在文内的引文处按引用文献在论文中出现的先后顺序以阿拉伯数字连续编码,序号置于方括号内。同一文献在一文中被反复引用者,用同一序号标示。

这一规定使得所列文献简洁明了,应该引起论文作者注意。英文参考文献和中文参考文献一样,按在文中出现的先后顺序与中文文献混合连续编码著录;英文文献用印刷体;英文书名、期刊名和报纸名等用斜体;所列项目及次序与中文文献相同,但文献类型可不标出;忌用中文叙述英文。其格式为:

专著、论文集、学位论文、报告主要责任者。文献题名。出版地:出版者,出版年。起止页码。示例:Day,C.,Veen, Walraven,G. Children and youth at risk and urban education. Research, policy and prac-tice. Leuven/Apeldoorn:Garant. 1997.

期刊文章:主要责任者。文献题名。刊名,年,卷(期):起止页码。示例:Driessen,G.,& Van der Grinten,M. Home language proficiency in the Netherland:The evaluation of Turkish andMoroccan bilingual programmes- A critical review, Studies in Educational Evaluation,1994, 20(3):365- 386.

论文集中的析出文献析出文献主要责任者。析出文献题名。原文献主要责任者(任选)。原文献题名。出版地:出版者,出版年。析出文献起止页码。

示例:Driessen,G.,Mulder,L.,& Jungbluth,P. Structural and cultural determinants of educational opportunities in theNetherlands. In (Ed.),Root and migration in global perspective. Jerusalem:Magnes . 104.

二、关于英文人名的标注

现行编排规范对英文人名如何标注未作明确要求,英文人名的标注较为混乱,有标注全名的,有标注时将名缩写、姓不缩写、保持原来顺序的,还有在姓、名之间加圆点的,后者是我国翻译作品中,中文书写外国人名经常采用的一种方式。

其实,标注英文人名是有章可循的,在国外学术著作的参考文献中,关于人名的标注已约定俗成为一种统一的格式,即英文参考文献标注作者姓名时,要求姓在前、名在后,姓与名之间用逗号隔开,姓的词首字母大写,其余字母不大写;名用词首大写字母表示,后加缩写符号圆点,缩写符号不可省略。由于欧美国家人的姓名排列一般是名在前、姓在后,在标注时必须加以调整。如Georg Paghet Thomson,前面两个词是名,最后一个词是姓,应标注为Thomson,G. P为什么要如此标注呢?

1. 在应用计算机等信息工具进行英文文献检索时,以英文作者姓名中的姓作为依据之一,即以姓作为检索目标之一。

2. 在欧美人姓名表达含义里,姓比名的重要性更强、更正式。用姓而不是名来代表作者,还有尊重、礼貌的意味。名缩写后加缩写符号圆点,也含有正式、尊重和礼貌的意味,缩写符号不可省略。

3. 表示与平常书写姓名的不同,体现学术论文重要性、简约性和准确性的要求,符合科研论文文体风格。这种标注在英文学术著作、科技文献中已广泛采用,也容易被广大读者、作者理解、接受。

对于复姓情况,如Jory Albores-Saavedra等,在引用标注时,应将复姓全部写出,即Albores-Saavedra, J对于姓前带有冠词或介词的情况,如带有Mac,Le,Von,Van den等,标注时不能省略,应同姓一起提到前面标注,如Mac Donald,La Fontaina,Von Eschenbach,Van den Bery等。

一个参考文献有两位或两位以上作者时,标注时除按上述要求将每位作者的姓提前书写外,作者与作者之间用逗号分开,最后一位作者前加&符号,如示例[1],也可仅保留前三位作者,之后加etc.表示。

给排水英语论文参考文献

用TimesNewRoman。每一条目顶格,如某一条目超过一行,从第二行起“悬挂缩进”2字符。参考文献中所有标点与符号均在英文状态下输入,标点符号后空一格。参考文献条目排列顺序:英文文献、中文文献、网络文献。分别按作者姓氏字母顺序排列。文献前不用序号。英文参考文献专著与编著排列顺序为:作者姓、名、专著名、出版地、出版社、出版年。

一般情况尽量用英文的,如果是写的国内的情况,当然可以参考中文资料,具体还要看学校和导师的要求

哈哈 只要书名?看这个吧!national standard plumbing code美国供水规范global_water_supply_and_sanitation_assesment_2000_reportHandbook for developing watershed plans to restore and protect our waters 美国EPA污水处理手册handbook

是这样的,不同的学院有不同的要求。我将我们院的陈述一下,给楼主一个参考。写英语论文不可能只遇到英语参考文献对不对,还有很多中国人自己发表的研究性论文啊什么的都可以作为文献来参考。我们要求参考文献在30个以上,其中外文文献(就是非中文的文献,从出版社到作者都是外国的那种)不能低于一半就是15个。然后这个论文引用是有格式要求的。具体来说,就是:1,专著类:作者. 书名[M]. 出版社所在地:出版社名称,该书出版时间:页码.,2,期刊类:作者. 文章标题[J]. 文章发表的期刊名,文章发表的年(第几期):页码(起止页码).参考文献是要另起一页写的。才答辩完,希望能够帮到楼主~!

水厂设计毕业论文

我从给排水工程书上扫描的图片给你吧,把类型和特点描述的很详细了,希望对楼主有帮助。

给你一篇范文参考下,自己修改下里面的东西吧,详细内容见网址:字绝对到了的排水工程专业毕业水厂实习总结报告 中科软件园整理 毕业实习是给水排水工程专业教学计划中非常重要的实践性教学环节之一,其目的是使学生更加深入地了解和掌握专业知识,扩大学生的专业知识范围,加深和巩固所学的理论知识。使学生了解工程建设的程序以及各设计阶段的设计深度和要求,掌握城市给水工程、排水工程设计内容、步骤与方法;提高学生综合运用专业知识解决工程实际问题的能力。同时通过实地参观学习、导师指导以及资料查询等实习方式,收集与毕业设计(论文)题目有关的资料,为毕业设计(论文)作好准备。 实习地点: 自贡市第一水厂(长土) 自贡市中联环水净化有限公司污水处理厂 实习时间: 至 自贡市第一水厂实习 (一).水厂简介: 自贡市第一水厂(长土水厂)座落在贡井区长土镇,始建于1958年,设计日处理水能力为万吨/日规模。水厂的水源主要为双溪水库水,通过20多公里渠道和后端8公里管道输送到厂,最大输水能力为5万吨/日单管输水;旭水河重滩堰为该厂的安全备用水源。水源水质达到国家集中式取水地面水源水质标准。水厂主供贡井城区和汇东部分城区。水厂环境优美,为省级园林式绿化单位。一水厂水处理生产工艺为:根据源水水质情况,在引水管道上进行前加氯,源水进入反应池后,在反应池中添加混凝剂进行混凝反应,随后进入沉淀池进行沉淀反应,沉淀之后的水进入滤池过滤,滤后水经过加氯消毒后进入清水池。清水池的水经过送水泵站送到城市管网。该厂目前在加氯和投药两个工艺实行了自动化管理,生产过程实现适时监控。确保出厂水水质达到国家饮用水卫生标准要求。 (二).实习内容: 1.了解城市水资源情况,水厂水源情况,水厂厂址选择原则,出水水质要求。 自贡市水资源情况:自贡市属缺水城市,存在资源性、工程性、水质性缺水的特点,缺水原因:1.不傍大江大河,境内缺乏大型骨干水利工程,水资源总量及工程调控能力有限。2.工业企业污染严重,城区过境的威远河、釜溪河的部分河段水质已基本丧失使用功能。3.降雨量时空分布不均。旱灾频率高达。由于自贡市去年遭受80年难遇的特大旱灾后,冬干、春旱接踵而至,致使现有的水利工程蓄水严重不足。尤其是作为自贡城区供水重要水源的双溪水库,蓄水量严重不足。使得城区生活、生产用水矛盾突出。 水厂水源情况:主要水源是双溪水库的优质水,其备用水源为旭水河河水。 水厂地址:在旭水河的上游土丘处,距河岸较近,便于修建岸边式的取水泵站。地距供水区:贡井区、自流井区的位置相对较近,且方便来水从荣县的双溪水库重力自流到自贡市的长土镇。距公路较近,交通方便。 出水水质:采取远程在线监控:原水水质控制点(在线浊度监控仪、原水水质采样导管)、滤前水质控制点、滤后水质控制点(水质取样、浊度、余氯量监测仪)、出水水质控制点、出水水量计、出水水压表,严格控制出水水质。 2.了解水厂的规模,工艺流程,平面及竖向布置情况。 水厂规模:自贡市供排水公司第一水厂规模为10万m3/d的老水厂 工艺流程: 3.了解水厂使用净水药剂(混凝剂、助凝剂)的品种、投量和投加方式方式;消毒方法、投加量及投加设备。 4.熟悉和了解各单项构筑物的型式、构造、工作过程、基本设计参数以及运行管理的内容、方法和经验。 1)取水构筑物:设计原则及位置选择,形式和构造,操作管理的内容和方法,取水泵房的布置,给水水泵的选择及附属设备的选择。 2) 混合、反应设备(絮凝池):混合设备类型,设计运行参数。反应池形式、构造及设计要点,设计运行参数(流量、停留时间、G、GT)。 3) 斜管沉淀池:构造、工作特点、设计运行参数和附属设备情况。 4) 重力无阀滤池:构造,工艺尺寸,配水系统形式,滤料种类,级配及层数,冲洗方式、强度及历时,膨胀度,冲洗水的供给及排除,管廊布置,自动控制设备,滤池运行操作程序,处理效果等。 5) 消毒设备:消毒方法,加氯量,加氯间及氯瓶库布置。 6) 清水池及送水泵站:清水池容积、构造及尺寸,送水泵站的工作特点,水泵布置和调度方式。 5、了解水厂自动化设施及运行情况。 6、了解水厂的组织管理及运行的指标,包括人员编制、漏失水量和水厂自用水量,每吨水的电耗、药剂消耗量、制水成本和水价等。 (三)实习体会: 通过到水厂实地参观学习,首先对水厂近期的工作情况,工作任务,水源问题,生产工艺有了更进一步的了解,尤其是对水源的突变问题,提出的解决方案有了初步的了解。其次,实地观察制水工艺,这是一座的传统工艺,60年代建成时产水几千吨,后由于城市的发展需要,经改造扩建后变成2万吨、3万吨、8万吨,其中无阀重力式滤池老系统是95年建成投产,新系统是99年建成投产,逐渐完成生产能力增大的改变,对处理工艺:絮凝—沉淀—过滤的工艺流程,以及其工作原理有了更深入的了解,并将理论联系实际,从理论认识到感性认识,更加深刻地掌握了以往所学的知识,理论指导实践,并在这个过程中发现自己理论认识不完善、不全面的地方,更发现了一些自己错误的认识,再结合书本,进一步纠正和完善自己的理论知识,以此完善和提高自己的专业知识。 (四)实习反思: 水厂设计的优点:1.水厂厂区园林式的设计理念,体现了“环保”思想。2.采用双水源(主水源和备用水源)供水,确保了供水的安全性。3.采用在线监测系统和自动化管理,严格确保出厂水水质达到国家饮用水卫生标准。 水厂设计的不足:1.设计时未充分考虑到水厂的发展需要,没有预留足够的发展用地。2.对水源水质、水量的变化,以及一些突发性问题没有足够的预见,所以在问题出现时,没有及时的解决方案。3.由于水厂的建立是在60年代,虽然后经过一系列的改造,但其生产工艺仍然较为落后,抗冲击能力较弱。 反思:在以后的学习、工作中,我们一定要站在一个高度看问题,分析问题要深刻、仔细、全面,尤其是在我们做设计的时候。 二.自贡市中联环水净化有限公司污水处理厂实习 (一).污水处理厂简介: 该工程由城市截污管道工程和城市污水处理厂工程以及中水回用工程等配套工程组成。其中,城市污水处理厂工程总规模为污水处理10万吨/日,分两期建设。第一期工程建设规模为5万吨/日,概算投资7500万元,其中厂区投资4785万元,建设用地49亩,工程采用BOT运作模式,由北京中联环工程股份有限

毕业论文的课题要求(包括所具备的条件)是写关于专业的内容。这种撰写具体思路如下,不过不同学科还稍微有些差别。要明确课题的目的和意义,从理论和应用两个层面来着。

具体条件,就是完成论文所必须的基础,比如理论基础、实验基础以及完成他们所必须具备的前提条件、数据和程序等,可以包括图纸资料、成果资料、影音图像等等。论文预计成果,可以是专利、大小论文和程序代码等等。

写作技巧

1、论文题目应能概括整个论文最重要的内容,言简意赅,引人注目,一般不宜超过20个字。标题字体为2号黑体加粗、居中;而论文副标题为小2号字,紧挨正标题下居中,文字前加破折号。在填写姓名、专业、学号等项目时,字体用3号楷体。

2、论文摘要应阐述学位论文的主要观点。

1. 论文的标题 毕业论文的标题是论文的眉目,应仔细推敲,尽可能从各个角度充分考虑,选择最合适的。原则上,题目要简单明了,能反应毕业论文的主要内容,使读者能一眼看出论文的的中心内容要讲什么,切忌笼统、空泛。语言也要补实,同时能引起读者的注意。 毕业论文的标题不能象小说、散文那样经过艺术加工而引起读者的好奇心。论文的题目要让人一看就能直接了解它的论文。因此,拟题要采取直接、正面的提高论文内容的方法,而不要采取奇特的艺术手法。标题不可过长,尽量在20个字以内。 2. 目录 毕业论文篇幅长的要写出目录,使人一看就可以了解论文的大致内容。目录要标明页数,以便论文审查者阅读方便。 3. 内容摘要 内容摘要要求把论文的主要观点提示出来,便于读者一看就能掌握论文内容的要点。目前比较通用结构式摘要,包括研究目的、方法、结果和结论。摘要应有高度的概括力,且要全面反映论文要点,简明、明确、畅达。 4.正文 正文包括前言、材料与方法、结果、讨论。主要包括序论、本论文、结论三个主要部分。序论要对论题的主旨、写作的动机和理由、研究的方法以及论文的内容加以简要说明,通常几百字即可。本论是全篇论文的核心,在篇幅上占得最多,写时必须慎重对待,这一部分,作者要对所研究的问题进行分析、论证、阐明自己的观点和主张。结论,要把这部分写得简明扼要,既要考虑与序论部分相照应,还要考虑与本论部分相联系。结论应是本论部分阐述的必然结果。讨论部分可以展开写,写前人的研究情况与自己的研究结果比较,提出自己的观点和主张,提出值得进一步研究的方向和倾向性意见。 5.参考文献 毕业论文的卷末要列出参考文献。列出参考文献的好处是:一旦发现引文有差错,便于查找;审查者从所列的参考文献中可以看出论文作者阅读的范围和努力的程度,便于参考。 6.论文的装订 论文的有关部分全部抄清完了,经过检查,再没有什么问题,把它装成册,再加上封面。 毕业论文的封面要朴素大方,要写出论文的题目、学校、科系、指导教师姓名、作者性名、完成年月日。论文的题目的作者姓名一定要写在表皮上,不要写里面的补页上。封面可以这样写(不同学校有不同的要求):××××大学计算机××××专业××届毕业设计论文 专业班级:

相关百科

热门百科

首页
发表服务