首页

> 论文发表知识库

首页 论文发表知识库 问题

心电图机检测论文

发布时间:

心电图机检测论文

心电放大器一、设计目的 学习三运放电路工作原理与设计方法; 学习差模信号与共模信号;熟悉巴特沃兹低通滤波器的设计。二、设计内容与要求设计心电放大电路,技术指标如下:差模放大倍数AVD=100; 共模抑制60dB;通频带0~30Hz。阻带截止深度40dB. 三、心电放大器基本原理心电放大器即心电图( Electrocardiogram) 信号放大器。将Ag2AgCI 电极贴在病人左臂、右臂和大腿上,从体表获得的心电信号经集成运放CF318 构成的前置放大器放大后,再经滤波处理,然后进入ADC 进行模数转换,送记录仪或液晶显示。因此一高阻抗、高增益的放大器是准确获取心电信号的关键。心电放大器模拟部分如下图所示:确定心电放大器的性能指标 (1) 人体心电信号幅度一般在50μV~5 mV ,属于微弱信号,放大器输出信号一般在- 5~ + 5V ,因此,要求放大器的差模电压增益为100左右;(2) 信号的频率范围(通频带) 一般为0-30Hz;(3) 人体内阻、检测电极与皮肤的接触电阻为信号源内阻,阻值一般为几十kΩ ,为了减轻微弱心电信号源的负载,要求放大器的差模输入阻抗大于10 MΩ;(4) 人体相当于一个导体,将接收空间电磁场的各种干扰信号,它们对放大器来说相当于共模信号,因此放大器的共模抑制比为60dB;(5) 要求具有低噪声和低漂移特性。微小信号的放大方案设计:(1)采用多级集成运放实现差模电压的高增益,且各级增益均衡分配。 (2)三运放放大电路:由于输入阻抗、共模抑制比和噪声主要取决于前级,因此输入级采用集成运放CF318构成前置放大器,该运放能实现高输入阻抗和低噪声。该放大电路分两级,第1 级:A1 、A2 及相应电阻构成前置放大器。第二级采用差分式放大电路实现信号放大。两级总的放大倍数为5倍。电路图如下: 该电路输出特性为: 当 =100k, =k=51k, = =100k时,Vo=-5Vi该放大器第一级是具有深度电压串联负反馈的电路,所以它的输入电阻很高。如选用相同特性的运放,则它们的共模输出电压和飘移电压也都相等,组成差分式电路以后,可以互相抵消,所以它有很强的共模抑制能力和较小的输出飘移电压,同时该电路可以有较高的差模电压增益。(3)二阶巴特沃兹低通滤波放大电路:具有理想特性的滤波器上很难实现的,只能尽量逼近理想特性,常用的逼近方法有巴特沃兹(Butterworth)最大平坦响应和切比雪夫(C h e b y s h e v )等波动响应。切比雪夫滤波电路的截止频率处衰减快,但通带里有较大波动。在不允许通带里有较大波动的情况下,为了在通带范围内可得到最平坦的幅频曲线,选择Butterworth 型二阶低通滤波电路. 它结构简单,带内纹波小,滤波效率高。由于50 Hz的干扰信号较强,故在滤波电路中,采取低通滤波滤出30Hz 以上的信号,这样就能滤除30Hz以上的干扰信号。因此采用集成运放A4 及电阻、电容组成低通有源滤波器。为满足带宽要求该低通滤波器由C 、R10 构成,上限频率为f H = 30Hz, 由于在滤波电路中采用了RC 低通滤波电路,该电路具有较高的输出阻抗,所以后级放大采用了同相放大电路,该级差模增益为2倍 ,从而保证整个电路放大倍数为125倍左右。另外,由于该滤波器的特性参数对元器件的精度很敏感,因此在设计中需用精密的阻容元件来获得较好的效果。电路原理图如图2 所示。二阶低通滤波器的传递函数 其中, ,等效品质因数Q=1/(3-A),特征角频率 截止频率f=30Hz,C=, ,计算得R=,取标称值为51k,获得的放大倍数为 ,为保证放大倍数A=2,取Rf k.=100KM,R1.=100K。(4)反向比例放大电路:用集成运算放大器A5构成的反向比例放大电路,应为该电路的输入电阻比较大可以直接接在滤波电路后面,整体要求整个电路的放大倍数为100左右,因此此级放大电路的放大倍数约为5~6倍才能满足设计要求。其电路图如下: 对于这个电路,其放大倍数为AV=Rf/R1.可以取R1=R2=10K,Rf=51K。(5)将以上三个电路合在一起就组成整个电路的电路图。如下所示: 四、器材选择1、 在三运算放大电路中,前面的两个分压电阻阻值应比较大且精度较高,因为在该处要形成一组大小相等,相位相反的差模电压,如果电阻阻值较低或者精度较低都会产生较大的误差,经过集成运放放大后的误差更大,从而影响的本来就很微弱的心电信号的测量。因此可以选金属膜电阻器RJ型阻值为30M的高精度电阻。2、 心电信号的大小大约在50�0�8V~5mV左右,经过第一级三运放放大电路放大后的电压也只是几十毫伏,电压较低,因此功率不会超过一般电阻的额定功率。因此一般的电阻都能够满足要求.可以选用碳膜电阻RT型。3、 对于含有集成运放的电路,都必须要考虑调零的问题,而对于测量心电信号这样的小信号,调零的必要性显得尤为重要。调零方法:在1脚和5脚之间加一个调零电位器,其阻值为0~10KΩ,将输入端短接,测量输出端电压,调节电位器,使输出电压为零即可。4、 本电路要求共模抑制比大于60dB,具有高精度,低漂移,温度系数小,输入电阻大等特点,综合考虑可以选用CF318集成运放。对于集成运放CF318,其各脚功能如下:1,5既可以是调零又可以是相位补偿,2为反相输入端,3为同相输入端,4为负电源,7为正电源,6为输出端,8也是相位补偿。因此用CF318可以直接在1和5之间外接一个电位器对运放以及整个电路进行调零。5、 电路要求共模抑制比为60dB,KCMR=|AVD/AVC|,此电路无法直接计算出共模电压增益,只能通过测量的方法测出共摸电压增益。测量方法:将两输入端接在一起和一个电压为Vi的输入信号相接,测量输出端的电压VO,可以得到AVC=VO/Vi,计算出共摸抑制比。6、 30HZ二阶巴特沃兹低通滤波电路要求所测的信号的频率范围为0~30HZ,要求低通滤波器在0~30Hz平坦特性比较好。巴特沃兹低通滤波器具有最大平坦特性。选用二阶巴特沃兹低通滤波器的各元器件的参数如下:C1=C1=�0�8F, R=.由于1�0�8F以上的电容大都为电解电容,滤波效果不好,而100pF以下的电容容易产生分布电容,因此这里选用CT4型号的中的�0�8F的无机介质电容,它的工作电压为40~100V,温度范围-25~85度,完全满足该电路的设计需要。对电阻的要求不是很高,可以选用最常用的碳膜电阻RT型。

Motion Analysis of the Right Ventricle Using an Electromechanical Biventricular ModelThree-Dimensional Motion Analysis of the Right Ventricle Using an Electromechanical Biventricular MoLecture Notes in Computer Science3314<>,夏灵,霍梅梅 Level Electromechanical Modeling and Simulation of Heart Failure心室肌细胞电生理-力学复合模型在心力衰竭中的仿真研究中国生物医学工程学报26<>,Yu Zhang, Ling Xia, et the evaluation of MRI coil excited RF fields inside a multilayered spherical head phantom using DyadicGreen’s function/MoM method多层球状头模型中MRI线圈激励下射频场的求解--并矢格林函数矩量法浙江大学学报(工学版)41<>,Ling Xia, et Parallel FDTD SchemeAn MRI-Dedicated Parallel FDTD SchemeConcepts in Magnetic Resonance Part B31<>,HUA WANG, ADNAN TRAKIC,Ling Xia, et of Ventricular Wall Motion Based on an Electromechanical Biventricular ModelAnalysis of Ventricular Wall Motion Based on an Electromechanical Biventricular ModelIEEE Computers in Cardiology30<>,夏灵,霍梅梅 Modeling and Simulation of Short QT SyndromeCellular Modeling and Simulation of Short QT SyndromeDYNAMICS OF CONTINUOUS, DISCRETE AND IMPULSIVE SYSTEMS<>, 20070910Yu Zhang, Ling Xia, et Three-dimensional Electromechanical Model of Canine HeartA Three-dimensional Electromechanical Model of Canine HeartDYNAMICS OF CONTINUOUS, DISCRETE AND IMPULSIVE SYSTEMS<>, 20070910Jianhong Dou, Ling Xia, et Numerical Methods for Solving the Membrane Equations of Human Ventricular Cell ModeEfficient Numerical Methods for Solving the Membrane Equations of Human Ventricular Cell ModeJournal of Computational and Theoretical Nanoscience4<>, 20070910Yu Zhang, Ling Xia, et the Electrocardiography Inverse Problem by Using an Optimal Algorithm Based on the Total Least Squares TheorySolving the Electrocardiography Inverse Problem by Using an Optimal Algorithm Based on the Total LeaProceedings of ICNC07<>, 20070901Guofa Shou, Ling Xia, et Analysis of Mechanical Properties of the Canine Heart with Bundle Branch Block Based on a 3-D Electromechanical ModelSimulation Analysis of Mechanical Properties of the Canine Heart with Bundle Branch Block Based on aComputers in Cardiology<>, 20070901Ling Xia, et Regularization Frameworks for Solving the Electrocardiography Inverse ProblemCombining Regularization Frameworks for Solving the Electrocardiography Inverse ProblemProceeding of ICIC07<>, 20070801Mingfeng Jiang, Ling Xia, et of Efficient Numerical Methods in Solution of Ordinary Differential Equations for Modeling Electrical Activity in Cardiac CellsApplication of Efficient Numerical Methods in Solution of Ordinary Differential Equations for ModeliProceeding of ICIC07<>, 2007080Yu Zhang, Ling Xia, et Solution in Simulation of Cardiac Excitation Anisotropic PropagationParallel Solution in Simulation of Cardiac Excitation Anisotropic PropagationLNCS4466<>, 2007060Yu Zhang, Ling Xia, et Electroardiographic Imaging: Application of Hybrid Methods for Solving the Electrocardiography Inverse ProblemNoninvasive Electroardiographic Imaging: Application of Hybrid Methods for Solving the ElectrocardioLNCS4466<>, 20070601Mingfeng Jiang, Ling Xia, et of the LSQR method and a genetic algorithm for solving the electrocardiography inverse problemCombination of the LSQR method and a genetic algorithm for solving the electrocardiography inverse pPhys. Med. <>, 20070210Mingfeng Jiang, Ling Xia, et and Inverse Solutions of Electrocardiography Problem Using an Adaptive BEM MethodForward and Inverse Solutions of Electrocardiography Problem Using an Adaptive BEM MethodLNCS4466<>, 20070201Guofa Shou, Ling Xia, et Motion Analysis of Right Ventricular Based on an Electrophysiologic-mechanicai Composite Heart Model基于电生理一力学复合心脏模型的右心室三维运动分析生物医学工程学杂志24<>, 20070201Ling Xia, et Use of Genetic Algorithms for Solving the Inverse Problem of ElectrocardiographyThe Use of Genetic Algorithms for Solving the Inverse Problem of ElectrocardiographyProceedings of the 28th IEEE EMBS Annual International Conference<>, 20061001Mingfeng Jiang, Ling Xia and Guofa Parallel FDTD Scheme for Electromagnetic Analysis and Design of MRI SystemA Parallel FDTD Scheme for Electromagnetic Analysis and Design of MRI SystemProceedings of the 28th IEEE EMBS Annual International Conference<>, 20061001Hua Wang, Adnan Trakic, Ling Xia, Stuart Crozier, Feng Liu and Marek comparison of different choices for the regularization parameter in inverse electrocardiography moA comparison of different choices for the regularization parameter in inverse electrocardiography moProceedings of the 28th IEEE EMBS Annual International Conference<>, 20061001Guofa Shou, Mingfeng Jiang, Ling Xia, Qing Wei, Feng Liu and Stuart Heart Model Construction and ECG SimulationElectrodynamic Heart Model Construction and ECG SimulationMethods of Information in Medicine45<5>, 20061001L. Xia, M. Huo, Q. Wei, F. Liu, S. of Brugada syndrome using cellular and three-dimensional whole-heart modeling approachesSimulation of Brugada syndrome using cellular and three-dimensional whole-heart modeling approachesPHYSIOLOGICAL MEASUREMENT27<>, 20060918Ling Xia, Yu Zhang, Henggui Zhang, Qing Wei, Feng Liu and Stuart Solution of Bidomain Equations in Simulation of Cardiac Excitation Anisotropic PropagationEfficient Solution of Bidomain Equations in Simulation of Cardiac Excitation Anisotropic PropagationLecture Notes in Computer Science4115<>, 20060810Yu Zhang, Ling Xia, Guanghuan Solution of Bidomain Equations in Simulation of Cardiac Excitation Anisotropic PropagationEfficient Solution of Bidomain Equations in Simulation of Cardiac Excitation Anisotropic PropagationLecture Notes in Computer Science4115<>, 20060728Yu Zhang, Ling Xia, Guanghuan simulation study of ECG T-wave alternation caused by ultrahigh static magnetic fields超高静磁场引起心电图T波变化的电生理学初步仿真研究国际生物医学工程杂志29<3>, 20060628罗如意,夏灵,朱 of cardiac motion on body surface electrocardiographic potentials:an MRI-based simulation stuEffect of cardiac motion on body surface electrocardiographic potentials:an MRI-based simulation stuPHYSICS IN MEDICINE AND BIOLOGY51<>, 2006062Qing Wei, Feng Liu, Ben Appleton, Ling Xia,et Study of Body Surface ECG Based on a Dynamic Heart Model基于动态心脏模型的体表心电图仿真研究中国生物医学工程学报25<3>, 20060620夏灵,叶学松,霍梅梅,刘锋 in ion-channel-based myocardium modeling and simulation基于离子通道的心肌细胞建模与仿真研究进展国外医学生物医学工程分册28<5>, 200陆晓华,夏灵 and Simulation of Transmural Cellular Electromechanical Properties in Heart FailureModeling and Simulation of Transmural Cellular Electromechanical Properties in Heart FailureIEEE Computers in Cardiology32<>, 20050924张宇,寿国法,黄然,夏灵 Modeling and Simulation of Brugada SyndromeCellular Modeling and Simulation of Brugada SyndromeIEEE Computers in Cardiology32<>, 20050924夏灵,张宇,陆晓华<>, Heart Model Incorporating Real Geometry and MotionAn Electrical Heart Model Incorporating Real Geometry and Motion<>, 20050901Ben Appleton, Qing Wei, Nianjun Liu, Ling Xia, Stuart Crozier, Feng Liu, Stephen Study of Transmural Cellular Electrical Properties in Failed Human HeartSimulation Study of Transmural Cellular Electrical Properties in Failed Human Heart<>, 2005090张宇,寿国法,夏灵 modeling study of ECG T-wave alternation caused by ultrahigh static magnetic fieldsElectrophysiological modeling study of ECG T-wave alternation caused by ultrahigh static magnetic fi<>, 20050901罗如意,张宇,夏灵 Level Electromechanical Modelling and Simulation of Heart FailureCellular Level Electromechanical Modelling and Simulation of Heart Failure<>, 20050901黄冉,张宇,夏灵 of Cardiac Ventricular Wall Motion Based on a Three-Dimensional Electromechanical Biventricular ModelAnalysis of Cardiac Ventricular Wall Motion Based on a Three-Dimensional Electromechanical BiventricPhysics in Medicine and Biology50<>, 20050421Ling Xia, Meimei Huo, Qing Wei, Feng Liu, Stuart <>, study of heart stimulation caused by MRI electromagnetic fieldMRI中电磁场对人体心脏影响的模型仿真研究国外医学生物医学工程分册28<>, 20050201陶贵生,夏灵,何超明39.基于离子通道的心肌细胞建模与仿真研究进展国外医学生物医学工程分册28<>,<>,<>,<>, <>,<>,<>,中电磁场对人体心脏影响的模型仿真研究国外医学生物医学工程分册28<>, designed Finite-difference time-domain simulator for electromagnetic analysis and design in MRI—applications to high field analysesAn object-oriented designed Finite-difference time-domain simulator for electromagnetic analysis andJournal of Magnetic Resonance172<>, 20041201魏青,刘锋,夏灵,S. <>, Heart Modeling and SimulationBeating Heart Modeling and SimulationIEEE Computers in Cardiology31<>, 200409夏灵,霍梅梅,张昕50. Object-oriented Designed Finite-difference Time-domain Simulator for Electromagnetic Analysis and Design in MRIAn Object-oriented Designed Finite-difference Time-domain Simulator for Electromagnetic Analysis and<>, 20040901魏青,S. Crozier,夏灵,刘锋 Analysis of Right Ventricular Wall Based on an Electromechanical Biventricular ModelMotion Analysis of Right Ventricular Wall Based on an Electromechanical Biventricular Model<>, 2004090夏灵,霍梅梅,刘锋52.?object-oriented?designed?Finite-difference?time-domain?simulator?for?electromagnetic?analysis?and?design?in?MRI—applications?to?high?field?analysesJournal?of?Magnetic?Resonance172<>,<>, of magnetically-induced E-fields on cardiac electric activity during MRI: A modeling studyInfluence of magnetically-induced E-fields on cardiac electric activity during MRI: A modeling studyMagnetic Resonance in Medicine50<6>, 20031201刘锋,夏灵,Stuart Progress of Heart Modeling and Simulation心脏建模仿真研究进展国外医学生物医学工程分册26<>, 20030201霍梅梅,夏灵 of the Influence of the Electrical Asynchrony on Regional Mechanics of the Infarcted Left Ventricle Using Electromechanical Heart ModelsAnalysis of the Influence of the Electrical Asynchrony on Regional Mechanics of the Infarcted Left Ventricle Using Electromechanical Heart ModelsJSME International Journal,Series A46<1>, 200301刘锋,夏灵,张昕 Analysis of the Mechanical Response of Human Left Ventricle Subjected to the Active Force心电激励下的人体左心室力学响应分析计算力学学报19<4>, 20021101夏灵,刘锋 Simulation Study of the Influence of Electrical Asynchrony on Regional Mechanics ofthe Ischemic Ventricle using Electromechanical Heart ModelsThe Simulation Study of the Influence of Electrical Asynchrony on Regional Mechanics ofthe Ischemic Ventricle using Electromechanical Heart ModelsIEEE Computers in Cardiology29<>, 20020924夏灵,霍梅梅,刘锋 Study of the Potential Hazards of Cardiac StimulationSimulation Study of the Potential Hazards of Cardiac StimulationIEEE Computers in Cardiology29<>, 20020924夏灵,刘锋,赵华炜 Progress of Nerve Stimulation and Cardiac Stimulation Caused by Electromagnetic Field in MRIMRI中电磁场对神经及心脏刺激的研究进展生物物理学报18<>, 20020601夏灵,何超明 Construction of Composite Finite Element Mechanical Model of Human Left Ventrical人体左心室复合材料有限元机械模型的建立中国生物医学工程学报21<>, 20020601吴国华,刘锋,夏灵,吕维雪 construction of ECG simulation model of beating heart跳动心脏的心电仿真模型建构生物物理学报17<>, 20010201张力锋,吴国华,夏灵 Construction of Three-Dimensional Composite Finite Element Mechanical Model of Human Left VentricalThe Construction of Three-Dimensional Composite Finite Element Mechanical Model of Human Left VentricalJSME International Journal, Series C44<>, 20010201刘锋,吕维雪,夏灵,吴国华 for outside surface potential: A new method of detecting cardiac electricity心电体外层电位仿真研究:一种检测心电活动的新方法中国生物医学工程学报20<>, 20010201吴国华,夏灵 Construction of Three-Dimensional Mechanical Model of Human Left VentricalThe Construction of Three-Dimensional Mechanical Model of Human Left Ventrical<>, 20001001吴国华,刘锋,夏灵 study of myocardium infarction based on heart model基于心脏模型的心肌梗塞病变仿真研究自然科学进展10<>, 20001001刘锋,肖国臻,刘亚群,夏灵,吕维雪 foundation and computation of body surface Laplacian ECG基于等效心电源的体表Laplacian图的理论基础及其计算浙江大学学报34<>, 20000301张尚军,夏灵,吕维雪 value studies of the contribution of body surface departure map on the localization of myocardial infarction体表电位积分差图在确定心肌梗塞区域中的价值研究中国生物医学工程学报19<>, 20000201徐文龙,夏灵,吕维雪 foundation of body surface Laplacian ECG based on realistic heart-torso model基于真实心脏-躯干模型的体表Laplacian图的理论基础中国生物医学工程学报18<>, 19990601张尚军,张翠英,夏灵,吕维雪 of Coronary Artery Stenosis with Heart-Torso ModelStudies of Coronary Artery Stenosis with Heart-Torso Model20<>, 19981001徐文龙,夏灵,吕维雪 of HIS Bundle Electrogram in a Computerized 3-D Heart ModelSimulation of HIS Bundle Electrogram in a Computerized 3-D Heart Model20<>, 19981001孙亚杰,夏灵,吕维雪 width measuring instrument with CCD for cold rolled sheet多通道CCD冷轧板材在线测宽仪钢铁33<9>, 19980901吴国华,夏灵,吕维雪 simulation studies of effect of myocardium electricity parameters on ECG rhythm心肌电特性参数对心律影响的定量仿真研究中国生物医学工程学报17<>, 19980301段云所,夏灵,吕维雪 for electrocardiographic inverse problem based on virtual heart基于虚拟心脏的心电逆问题研究中国生物医学工程学报17<>, 19980301夏灵,吕维雪 of the mechanism of reentry producing折返形成机制的仿真研究生物物理学报13<>, 19971001夏灵,张尚军,段云所,吕维雪 of Localization of the Ventricular Preexcitation Accessory Pathway using Heart Model Parameter OptimizationStudies of Localization of the Ventricular Preexcitation Accessory Pathway using Heart Model Parameter OptimizationIEEE Computers in Cardiology24<>, 19971001李光林,夏灵,吕维雪 of Implicit Information in BiosignalsExtraction of Implicit Information in BiosignalsMethods of Information in Medicine36<>, 19971001吕维雪,夏灵 progress on bioelectromagnetics生物电磁学的研究动态生物物理学报13<>, 19970901夏灵,肖国臻,吕维雪 of Localization of the Ventricular Preexcitation Accessory Pathway based on Virtual Heart Model Parameter Solution of ECG Inverse Problem心电逆问题的虚拟心脏模型参数解用于心室预激旁道定位的研究生物物理学报13<>, 19970601李光林,夏灵,吕维雪 Cardiac Arrhythmia Simulation ModelMicrocomputer-based Cardiac Arrhythmia Simulation Model34()<>, 19960601夏灵,吕维雪,段云所 New Approach to the Inverse Problem in ElectrocardiographyA New Approach to the Inverse Problem in ElectrocardiographyMedical & Biological Engineering & Computing34()<>, 1996060吕维雪,夏灵,魏大名 Study of Epicardial Potentials心外膜电位仿真研究中国生物医学工程学报15<>, 19960301吕维雪,夏灵 Simulation of Epicardial Potentials Using a Heart-Torso Model with Realistic GeometryComputer Simulation of Epicardial Potentials Using a Heart-Torso Model with Realistic GeometryIEEE Transactions on Biomedical Engineering43<>, 19960301吕维雪夏灵 studies of effect of myocardium electrical excitation conduct speed on arrythmia心肌电兴奋传导速度对心律失常影响的仿真研究生物物理学报12<>, 19960201段云所,夏灵,吕维雪 simulation of epicardial potentials using a microcomputer-based heart-torso modelThree-dimensional simulation of epicardial potentials using a microcomputer-based heart-torso modelMedical Engineering & Physics17<>, 00000000

心脏的收缩会产生微弱的电流,而通过特殊的仪器在人体表面采集到这种电流变化并形成一条波动的曲线,就是我们常见的心电图。心肌的血液供应不足或心肌细胞的病变等异常会引起曲线的不同改变,ST-T改变就是其中的一种,如ST段的压低或抬高、T波低平、倒置或高尖等。心电图是心内科常用的检查手段,特别是对冠状动脉硬化性心脏病(简称“冠心病”)有重要的诊断价值。很多患者或家属拿到心电图的打印报告常常会读到“ST-T改变”的诊断结论,同时可能被医生告知“心肌缺血”。但是ST-T改变一定等于心肌缺血,甚至冠心病吗?不一定。ST-T改变≠心肌缺血需要强调的是,心电图上的ST-T改变并不能和“心肌缺血”划上等号,更不能说ST-T改变就是患了冠心病。临床医生往往还要结合患者的年龄、致病的危险因素以及其他检查资料等做出诊断。除了冠心病以外,其他如瓣膜病、心包炎等心血管疾病,低血钾或高血钾等电解质紊乱,某些药物的影响,甚至植物神经功能紊乱都可以引起非特异性的ST-T改变。特别是心肌病、心肌炎、心脏X综合征等累及心脏微血管的疾病,都可能是心电图发现ST-T改变的重要原因。所以,大家对于自己心电图上可能出现的ST-T改变,不必“草木皆兵”,甚至盲目吃药,还是要清清楚楚地诊断,再明明白白地治疗。明确诊断,明白治疗目前,临床上24小时动态心电图检测、运动平板试验、心脏彩色多普勒检查、冠状动脉造影都是常见的冠心病诊断工具,特别是同位素心肌灌注显像检查是安全成熟有效的心脏病检查手段。虽然冠状动脉造影是目前冠心病诊断的“金标准”,但它只对心脏大血管具有诊断价值,而对于很多心脏微血管疾病却无能为力。而心肌同位素显像对于心肌缺血的范围判断、冠心病的确诊、心肌病的鉴别诊断、心脏微血管的诊断及治疗效果评判、心肌活力的测试等都具有重要的参考价值。

心电检测论文

网址: 或一篇现成的 群体性豆角碱中毒的急救与护理效果研究 目的 探讨豆角碱中毒的急救与护理及其临床效果。方法 对患者施行抢救组织管理、有效的催吐洗胃、静脉输液排毒,密切观察病情变化及群体心理护理。结果 125例中毒患者全部痊愈出院。结论 健全的急救系统、急诊护士的熟练的技术、有序分工合作和具备有条不紊的应急能力,是提高抢救成功率和护理质量的关键。 【关键词】 豆角碱;中毒;急救;护理 进食一定数量的未完全烧煮熟透或贮藏时间过久的豆角易致豆角碱中毒。我院于2005年8月成功抢救125例中毒患者,由于组织得力,措施合理及时,所有患者未出现严重的后遗症,全部痊愈出院。现报告如下。 1 临床资料 一般资料 125例患者均系某工厂工人,共同进食人数为196人,食用未煮熟的四季豆后发生中毒125例(占),均为急诊抢救患者。其中男47例,女78例;年龄20~52岁,平均32岁。食用四季豆量为250~480g,发病时间为进食后1~12h,平均。 临床表现 临床表现以急性胃肠炎为主,所有病例均有上腹部疼痛不适、恶心呕吐。呕吐物为胃内容物和胆汁,腹泻次数5~22次不等,平均为次。大便为稀水样,无脓血,无里急后重感。出现中度发热9例,有轻度畏寒和寒战。15例患者有头昏、眩晕、乏力、口干苦。123例神清,2例神志恍惚,均有轻到中度脱水貌,四肢冷,血压低于正常,心率快,心律不齐,出现频发早搏3例。大便常规检查无异常。 治疗及转归 问明病史后,125例中毒者全部实施急诊催吐,效果不佳者予以洗胃、灌肠;开放静脉通路,吸氧,心电监测并给予大剂量维生素C、维生素K、地塞米松、补液等对症治疗。2例较重者转住院治疗,余123例在急诊留院观察。125例中毒患者全部痊愈。 2 抢救与护理体会 抢救工作的组织管理 在抢救集体中毒患者时,有秩序地组织抢救工作对抢救的成功起着重要作用。当急救中心护士接到120急救电话后,确定需要集体抢救时,立即报告科主任、护士长、医院值班领导,启动急诊科应急预备方案,急诊科全体医护人员5~15min到岗。在大批患者未入院前,参与的抢救人员迅速准备好抢救物品、药品、洗胃器械等用物,以便患者到达后能得到及时有效的救治。护理部从各科室抽调护士长充实护理队伍,分成接诊组、观察组、治疗实施组。根据病情的轻重缓急实施催吐、洗胃、生命指征的监护等抢救措施。 有效清除胃肠道毒物,减少毒素吸收,催吐、洗胃是抢救的关键[1] 对于轻、中度中毒患者,护理人员指导饮温开水催吐,每次300~500ml,用手指或压舌板压迫舌根刺激咽后壁催吐,反复进行,直至胃内容物吐出,并在旁说明催吐、洗胃的重要性,劝导说服病人,以取得患者的密切配合。重度中毒患者给予洗胃直至洗出液澄清、无味为止。洗胃液一般选用生理盐水,温度控制在30℃~35℃之间,以免洗胃液过热而加速毒物吸收,过冷则易产生寒战导致高热。洗胃时患者左侧卧位,头偏向一侧,插胃管时动作应轻柔,切忌粗暴,以免损伤食管及胃黏膜引起出血,洗胃过程中经常按摩患者胃部以促进毒物排出。并严密观察患者生命体征的变化。洗胃结束后,自胃管注入50%硫酸镁或20%甘露醇导泻药促使毒物排出。在洗胃过程中同时要密切观察患者的面色、脉搏,注意有无血性液体洗出,如有异常情况,及时报告医生。 迅速建立静脉通路,静脉输液可稀释和促进毒物排泄[2] 按病情轻重为全部患者建立静脉通路,输入维生素C、维生素K等药物,达到稀释毒素,促进吸收的毒物排泄,以减轻中毒症状的目的。患者几乎同时到达医院,数量多、秩序一般较混乱,患者容易出现恐惧心理,争先用药,护士应冷静、果断做到忙而不乱,严格执行“三查八对”制度,对于口头医嘱一定要复述一遍,核实无误后再执行,用药后及时记录,做好安全用药。

随着人们法制观念的不断提高,病人维权意识逐渐增强,对医疗护理提出了更高的要求,因心电监护仪使用不当导致的投诉也逐渐增加。本院2003年6月至2004年6月被投诉4起,2004年7月至2005年6月5起,2005年7月至2006年6月9起;护士巡视不到位、责任心不强、病情变化未及时发现8例,心电监护仪参数设置不当或报警系统不工作5例,对心电监护仪性能不了解影响抢救治疗2例,设备本身问题2例,监护收费问题1例。病人自我保护意识增强与护士服务观念转变相对滞后的矛盾 随着病人及家属法制观念的逐渐加强,对医护质量的要求也越来越高〔1〕。在医疗护理活动中过去根本不会酿成纠纷的问题,现在都可能引发投诉,病家认为花了钱就要得到最好的服务及疗效,稍有不当病人或家属就要“讨个说法”,更有甚者,认为病人进了医院,化了钱,就得治好病,如病情反复或恶化就会千方百计寻找医疗工作中的缺陷和漏洞,进行投诉;而心电监护仪又是摆在他们面前看得见,摸得着的东西,稍有不慎就会成为投诉对象。护理服务质量与病人期望值之间的矛盾 需要心电监护的病人相对病情都比较重,家属特别关注治疗护理情况,以为使用心电监护仪后病情就能得到控制,当病情出现变化时就难以接受;而护士在护理过程中操作稍不仔细,解释不到位,对病人关心与理解不够,没有形成良好的护患关系,也就会受到病人及家属的迁怒。 护理队伍的年轻化,护理人员对心电监护仪性能不熟、使用不到位 当前医院发展速度较快,年轻护士较多,护理队伍的年轻化也已经成为护理投诉的主要原因之一〔2〕。首先年轻护士资历浅,工作经验不足,加之上岗前没有进行系统培训,不同程度地存在对心电监护仪使用性能及设置不熟悉,其次,年轻护士缺乏必要的医患沟通技巧和交谈艺术。心电监护仪故障延误病情 有些心电监护仪由于长时间连续使用,或者使用不当,或者年久失修等各种原因发生故障,特别是一些平时使用心电监护仪很少的科室,医护人员没有定期检查,不能及时发现和处理故障,一旦病情有变化需要时,却未能及时监护而延误了病情的监测、治疗,导致病家投诉。心电监护仪的使用费用相对较高,以每小时计算,且药费、检查费、一次性物品的广泛应用,给病家带来沉重的经济负担,因此,他们对收费特别敏感,对心电监护仪所用时数常有争议,加之新闻媒体过分渲染,对收费不放心,而多数家属在高额的医疗费用支出后疾病仍未明显好转,故将怨气发泄到仪器的使用和收费上导致投诉。为了适应目前新形势下病人对护理服务质量的要求,必须不断强化护士的优质服务意识,牢固树立“以人为本,以病人为中心”的服务观念,尊重病人的合法权益,尽量满足其要求。如在行心电监护前应耐心向病人及家属做好解释宣教工作,介绍心电监护的目的及仪器的安全性,告知可能出现的报警声。在整个监护过程中应加强巡视和观察,注意心电监护仪参数的变化,出现报警声时能迅速做出处理,并及时记录和保存。As the legal concept of continuous improvement, the patient gradually build up their human rights awareness, health care for a higher demand, due to the use of ECG monitor misconduct also led to a gradual increase in complaints. Hospital from June 2003 to June 2004 were 4 complaints since July 2004 to June 2005 5, July 2005 to June 2006 9; nurse visits are not in place, do not have a strong sense of responsibility, timely detection of the disease did not change in 8 cases, ECG monitor improper parameter setting alarm system does not work or five cases, the ECG monitor the performance of emergency treatment do not understand the impact of two cases, two cases of the issue of the equipment itself, the issue of guardianship fees and charges in 1 case. Self-protection awareness of patients and nurses to enhance the concept of service is lagging behind changes in the conflict Patients and their families with the legal concept of the gradual strengthening of the quality of health care have become more sophisticated [1]. Activities in health care will not lead to disputes over the issue, now may lead to complaints that the patient and his family will be花了钱the best services and the efficacy, some patients or their family will be inappropriate "to have a say" and, worse, that the patient into the hospital, of the money, you must heal the disease, such as illness or deterioration of repeated medical work will do everything possible to find defects and flaws in the conduct complaints; and ECG monitor is placed in front of them visible and tangible things, a little carelessness will become the target of complaint. Quality and patient care services in the conflict between the expectations The need for ECG monitoring of patients is relatively heavier than the disease, their families pay special attention to health care situation, that the use of ECG Monitor can be brought under control after the disease, when a change in condition when it is difficult to accept; and nurses in the care process is not operating slightly careful to explain in place, concern and understanding for patients not enough, there is no good nurse-patient relationship, but also patients and their families will be the vent. Care of the younger teams, nursing staff on ECG monitor the performance of the wake of the use of non-place Faster development of the current hospital, more young nurses, care of the younger team care has become one of the main causes of complaints [2]. First of all, the young junior nurses, lack of work experience, coupled with no systematic pre-training, varying degrees of ECG monitor and the setting up of the use of performance are not familiar with, and secondly, the younger the patient the nurses lack the necessary communication skills and conversation art. ECG monitor the delay fault condition ECG monitor some time as a result of continuous use, or improper use, or repair a variety of reasons such as failure, in particular, a number of normal ECG monitor the use of small sections, medical personnel do not conduct regular inspections, timely detection and to deal with failure, once the necessary conditions have changed, but failed to delay care and monitoring of the condition, treatment, patient and his family led to complaints. ECG monitor the use of the relatively high cost per hour basis, and drugs, inspection fees, the widespread application of a one-time items, to the patient and his family a heavy financial burden, so that they are particularly sensitive to charges of heart Monitor electricity used by a number of often controversial when, in addition to the news media exaggerated the charges do not trust, and the majority of families in the high medical costs to be incurred in a marked improvement after the disease has not yet, it will vent their grievances to the use of equipment and fees the lead to complaints. In order to adapt to the new situation at present patients quality care, nurses must continue to strengthen the services, and firmly establishing the "people-oriented, patient-centered" concept of service, respect for the legitimate rights and interests of patients, as far as possible to meet their requirements. If the line before ECG patience to do a good job to explain the patients and their families and education on the purpose of ECG and the security apparatus, this may sound the alarm. In the guardianship process should strengthen the inspection and observation, attention to ECG monitor changes in parameters, sound alarms when there quickly to deal with, and to record and preserve a timely manner.

Abstract: Objective analysis of HRV data and the autonomic nervous system function test results of the relationship that exists between, systematic preliminary study of Tai Chi Chuan training on the impact of the status of autonomic nervous system. Methods 12 non-sports professionals as a control group of girls, girls 11 Tai Chi Chuan as a special experimental group. 23 subjects, respectively, in a quiet state, lie down - vertical test stand - lie down under the application of test techniques Holter monitoring for heart rate variability analysis of the frequency domain. Results (1) quiet at the high-frequency components of the experimental group (HF) ~ was significantly higher than that. (2) vertical - back lying lie down when the pilot of the high-frequency components of the experimental group (HF) ~ , total power (TP) ~ Hz was significantly higher than that. (3) the control group and experimental group the results of autonomic nervous system function tests, there was a significant difference. (4) lie down - vertical test of the added value of heart rate and RR interval adjacent to the margin of the square root of mean square (RMSSD), poor adjacent RR interval> 50ms total number of the percentage of the number of heartbeats (pNN50), high frequency component (HF) ~ , total power (TP) ~ Hz showed a significant negative correlation. Vertical - Test Center lie down to reduce the rate of value and high-frequency component (HF) ~ were significantly negatively correlated. Conclusion Long-term tai chi training will enable the systematic body resting vagal tone enhancement. Taijiquan special athletes in the supine position to a better state of vagal tone reflects the strength. Taijiquan athletes vagus nerve excitability is higher than the general population, less than sympathetic excitatory general population. Autonomic function tests and HRV-related indicators to reflect the body's autonomic nervous system function the same conclusion. Key words: autonomic nervous system; heart rate variability; Taijiquan; upright lie down experiments, upright lie down experiment .摘要: 目的 分析HRV数据和植物神经系统功能检查结果之间存在的关系,初步探讨系统化的太极拳训练对植物神经系统状况的影响。 方法 选取12名非体育专业女生作为对照组、11名太极拳专项女生作为实验组。23名受试者分别在安静状态、卧倒-直立试验、直立-卧倒试验下应用动态心电图监测技术对其心率变异性进行频域分析。 结果 (1)安静时实验组的高频成分(HF)显著高于对照组。(2)直立-卧倒试验后仰卧位时实验组的高频成分(HF)、总功率(TP) ~ Hz显著高于对照组。(3)对照组与实验组植物神经系统功能检查结果存在显著差异。(4)卧倒-直立试验心率的增加值与相邻RR间期差值均方的平方根(RMSSD)、相邻RR间期差>50ms的个数占总心跳次数的百分比(pNN50)、高频成分(HF)、总功率(TP) ~ Hz均呈显著性负相关。直立-卧倒试验中心率的减小值与高频成分(HF)呈显著性负相关。 结论 长期系统化的太极拳训练可使安静时机体的迷走神经张力增强。太极拳专项运动员在仰卧位状态下能更好的反映出迷走神经张力的强弱。太极拳运动员的迷走神经兴奋性高于普通人群、交感神经兴奋性低于普通人群。植物神经功能检查与HRV相关指标在反映机体自主神经功能状态的结论一致。 关键词:植物神经系统;心率变异性;太极拳;卧倒直立实验,直立卧倒实验 以下专业词汇不用翻: 直立-卧倒试验、卧倒-直立试验、高频成分(HF)、总功率(TP) ~ Hz、心率的增加值与相邻RR间期差值均方的平方根(RMSSD)、相邻RR间期差>50ms的个数占总心跳次数的百分比(pNN50)、HRV

电动机电气检测论文

基于PLC的数控机床电气控制简析摘要:对数控机床电气控制系统的控制方式、系统功能、主要实现部件,进行了选择和分析,然后给出一个完整的基于PLC的数控机床电气控制系统工作原理方案。关键词:PLC;数控机床;电气控制目前数控机床相关技术的发展,不仅要对各机床各个坐标轴的位置进行连续控制外,而且需要对机床主轴停止、转向和进给运动的启动和停止、刀库及换刀机械手控制、切削液开关、夹具定位等动作,进行特性次序控制。特定次序的控制信息,由输入/输出控制,如控制开关、行程开关、压力开关、温度开关等输入元件,继电器、接触器和电磁阀等输出元件控制,同时还包括主轴驱动和进给伺服驱动的使能控制和机床报警处理等[1~5]。随着可编程序控制器(PLC)技术的发展,上述综合功能是可以由数控机床中的可编程序控制器来完成的[1~2]。它是由输入部分,逻辑部分和输出部分组成,输入部分收集并保存被控制部分实际运行的数据,逻辑部分处理输入部分所取得的信息,并判断哪些功能需做出输出反应。输出部分提供正在被控制的许多装置中,哪几个设备需要实时操作处理。笔者基于PLC控制来分析对一类数控机床的电气控制设计,主要包括对控制方式的选择和分析;对电气控制系统中的主要实现部件进行分析和选用,以及提出完整的基于PLC的数控机床电气控制系统工作原理方案。1基于P LC的数控机床电气控制方式的选择数控机床电气控制方式优劣,决定了控制系统的成败[3,5]。本文所提及的系统,要控制机床实现高速高精度的加工,所以系统的性能至关重要:首先要根据预定要求和被控对象的特征、控制精度、系统运行速度等限制进行了综合考虑,同时,充分考虑系统的性能价格比等因素,确定X、Y轴采用PC机+运动控制器+电机+光栅尺的方式进行闭环控制。采用此种方式,PC机发挥了强大的文件处理功能、人机交互功能以及高速的数据处理功能,运动控制器则体现了高可靠性、高速性、高精度等优点,光栅尺则为系统提供了高达1μm的精度的位置信息。同时,运动控制器可以接入机床的各种传感器,并及时做出处理,提高了整个系统的可靠性和稳定性。运动控制卡只能接入少数几根轴,而运动控制器可以大量扩展轴的数目,为系统以后的升级带来便利。运动控制器同时还可以通过一个标准接口接入一个PLC系统,即运动控制器同时可以执行PLC功能。2数控机床的功能分析本文分析的数控机床,是一拖四的机床,有X、Y轴和四个Z轴上的伺服电机,来进行工作台定位;X、Y、Z轴可以联动,四个Z轴可以同时运动,也可以分开运动。为了提高加工精度,工作台的X、Y轴运动,利用光栅尺实现全闭环控制,对工作台进行精确定位。通过外扩模拟量I/O点对高速变频器进行控制,实现四个主轴电机可以进行启停分开控制,转速同步控制。X、Y轴进行两侧硬限位和软限位双重保护,对Z轴下侧进行软硬限位。主轴转速高达16万r/min,实现较高的加工效率,并配备专用的冷却水泵对电机进行冷却,同时实时检测电机温度,提供温度保护。为每根主轴安装机械手和刀库,实现自动换刀和手动换刀可选择。为了提高加工质量,机械手换刀后,进行刀具深度和位置检测。加工过程中,实时检测刀具磨损以及断刀情况,出现刀具失效,可以自动通过机械手换刀或者提示操作者手动换刀。为了稳定加工,系统具有高速的上下位机通讯功能,上位机可以随时对下位机进行控制,下位机也把各种信息传到上位机。3电气控制系统组成控制系统由PC机(工控机),SIMOTION,电源模块,电机模块,电机,光栅尺,SMC30(传感器模块),分布式1/0ET200M(包括数字量模块和模拟量模块),机械手,主轴变频器,高速主轴以及多个传感器以及限位开关组成。具体的分析及其选用如下:上位机上位机是一台PC机(工控机),主要负责从加工文件中读取需要数控机床加工流程(以钻孔为例)的钻孔的孔位和孔径信息,以及为用户提供友好的界面设定加工参数,最后通过TCP/IP协议,把这些数据传到运动控制器。 S IMOTION运动控制器SIMOTION D是整个控制系统地核心,所以SIMOTION D的运行速度和可靠性,会对整个系统产生决定性影响。本系统选择的SIMOTIOND内部结构,是由西门子PLC5300和西门子的运动控制CPU组合而成,所以继承了PLC工业运用上的高可靠性优点,同时也继承了运动控制系统对运动控制的灵活性。SIMOTION是一个全新的西门子运动控制,它是世界上第一款针对生产机械而设计的控制系统。SIMOTION的目的是为实现各种运动控制任务提供一种简单、灵活的控制系统。为了确保成为最佳的控制方案,SIMOTION的功能得到了很大程度的扩展。SIMOTION主要有三大功能:(1)运动控制;(2)逻辑控制,例如,对输入信号的逻辑门处理,以及对输出信号的分析与赋值;(3)工艺控制,例如压力控制、温度控制等。目前SIMOTION面向的行业,主要是运动复杂、速度及精度的要求较高的制造机械、包装机械,橡塑机械,锻压机械,纺织机械,以及其他生产机械领域。电源模块一般变频器的工作方式,为先把一定频率的交流电变为直流电,再由逆变器把直流电变为指定频率的交流电。SIMO-TION运动控制系统,采用通过电源模块把工业交流电变为直流电,再分配给多个电机模块的方式。电源模块分为可调电源模块和不可调电源模块。可调电源模块,可以根据参数把它转化出来的直流电稳定到一个指定的可变值,并且具有与SIMOTION通信的功能;不可调电源模块,只能输出一个固定的直流电压,而且不能同SIMOTION通信。电机模块电机模块主要是把540V或600V的直流电,逆变成指定频率的三相交流电,供给电机使用。目前的电机模块有两种类型:书本型和装机装柜型。书本型又分为单轴电机模块和双轴电机模块,单轴为3-200A;双轴为3-18A;电机模块和主控单元之间通过DRIVE-CLIQ接口,进行快速数据交换。因为要对X、Y和四个Z轴进行伺服控制,所以采用3个书本型双电机控制模块,来对6个轴进行控制。伺服电机伺服电机是数控系统的动力提供者,本系统的X、Y和4个Z轴,都采用的是高动态相应的交流伺服电机。电机可以进行矢量控制和伺服控制,电机上还带有旋转编码器,用来组成一个电机位置闭环系统,实现对电机的精确控制。电机本身所带编码器的精度在10μm左右。电机也具有DRIVE-CLIQ接口,可以实时上传电机的状态参数,在系统自动组态时,可以上传自己的铭牌数据,极大地方便了系统组态。同时电机上边全部用标准安全接口,为电机接线时,只需把相应的插头插入即可。光栅尺西门子伺服电机本身带有编码器,但是电机编码器的精度只能达到10μm,离要求的5μm差距较大。所以用外部光栅尺检测工作台的位置,并把精确的位置信息通过SMC30(传感器模块)转换成标准信号,传递给SIMOTION进行处理。光栅尺选用业界知名的RENISHAW公司产品中的RG4系列。变频器数控机床的主轴速度,要求的非常高(12万r/min以上),所以为了对高速主轴进行控制,要选择一种高速变频器。台达V系列可以满足高速主轴的频率要求。由于SIMOTION上没有用来同台达变频器进行通信的485串口,所以对台达变频器的控制,采用模拟量控制方式。方案为SIMOTION D扩展ET200M获得模拟量I/O来对台达变频器进行控制。高速主轴机床的主轴采用西风的F16 160000RPM高效率PCB钻孔主轴,采用全流道冷却系统,是一种高精度、高寿命、高稳定性的全功能PCB钻孔主轴。刀具加紧方式,采用启动夹紧方式,冷却系统则为干净的水循环利用,不能使用去离子水。为了对独一主轴进行保护,主轴内置NTC温度控制系统。其他传感器()lOMRON接进开关。本系统对工作台的回零,采用外部标志加编码器零位方式回零,工作台回零时的外部标记用接近开关来实现,同时4个Z轴限位,也是通过接进开关来实现的。本控制系统的限位回零采用此接近开关。(2)深度检测系统。本系统可以采用机械手自动换刀或者手动换刀,由于换刀过程中,会出现刀具的夹装位置不同,造成钻孔深度不同,也会出现刀具安装倾斜等情况。NCPCB ToolSetting Device(刀具检测系统)可以在自动换刀或者手动换刀后,进行检测刀具深度以及方向是否正确。4电气控制系统总体工作方案设计如图1所示,为该电气控制系统总体工作方案原理图。该电气控制系统总体工作方案是:PC机读取文件信息,把数据传递给SIMOTION D;SIMOTION D再根据这些收到的数据,控制电机模块驱动电机,带动工作台进行位置控制;光栅尺实时检测工作台的位置信息,并传递给SIMOTION D,实现对工作台进行位置调整,满足对位置的精度要求。由于光栅尺信号不能由SIMOTION D直接识别,所以通过传感器模块SMC30转换为标准的信号,传递给SIMOTION D。被ET200M从SIMOTION D接收到主轴的转速信息,通过模拟量模块输出一个相应的电压,控制变频器驱动主轴转动。工作台的工作状态,可以通过多个传感器(如接近开关、断刀检测传感器、深度检测传感器等)检测到并传入系统。这些传感器的信号先送到SIMOTION的扩展模块ET200中,再送入SIMOTION中,运用SIMOTION强大的工艺处理、逻辑处理能力,对这些信号进行处理,从而完成整个的加工任务。5结束语数控设备在我国已广泛生产和应用,但水平还不高,这严重制约着我国生产加工工艺的提高。究其原因,主要体现在电气控制部分。本文给出的数控机床电气控制思想和方法,经过长期运行,证明其设计合理,控制精度高,性能可靠,能大大提高生产效率和质量,不失为一种优秀的数控电气控制方案。参考文献:[1]李华.PLC在数控机床控制系统中的应用[J].职业圈,2007,(07X):158-159.[2]李纪三,舒朝君,刘永喜.PLC在数控机床功能控制中的应用[J].机床电器,2008,35(2):12-14.[3]仲兴国.利用PLC进行数控机床故障维修的方法[J].制造技术与机床,2008,(6):144-146.[4]卢成斌.PLC和变频器在车床数控改造中的应用[J].数控机床市场,2008,(1):94-96.[5]李铁军,张淑敏.PLC在数控机床电气控制方面的应用[J].机械工程师,2005,(9):23-25.

·风力发电电能变换装置的研究 ·电流继电器设计 ·基于DSP的电力谐波测量装置的研究 ·电力现场图像监测系统设计 ·电力现场监测系统的设计 ·电力电子CAI课件的研制 ·电加热炉PLC温度自适应控制系统的研究 ·电加热反应釜生产过程控制 ·电机自动试验系统设计 ·电机起动方法及其软起动的研究 ·基于虚拟仪器的电机变频实验系统 ·电动汽车驱动电机及控制系统 ·电动机智能软起动控制系统的研究与设计(PLC) ·低压断路器智能式脱扣器设计 ·低压断路器操动机构的设计及优化 ·低压动态无功补偿装置的设计 ·低压变压器及其继电保护设计 ·倒立摆系统控制研究 ·倒立摆控制系统开发

电动机故障诊断技术的应用分析论文

无论是在学习还是在工作中,大家一定都接触过论文吧,论文一般由题名、作者、摘要、关键词、正文、参考文献和附录等部分组成。相信写论文是一个让许多人都头痛的问题,下面是我收集整理的电动机故障诊断技术的应用分析论文,欢迎阅读与收藏。

摘要:

当前,大型机械设备中安装电动机是非常普遍的,是辅助机械设备生产功能的一种手段,然而电动机在长期不间断工作,在电能转化为机械能的过程中造成温度持续上升、电动机性能降低、工作效率低下、电动机出现故障的情况,因此故障诊断技术的快速发展是延长电动机使用寿命的关键。本文立足于现实角度,针对现阶段电动机容易出现故障的类型,维修管理中应用的故障诊断技术的如何应用进行分析。希望通过本次研究,来探讨故障诊断技术在电动机维修管理上的应用情况,从而对相关专业知识有更深层次的理解。

关键词:

故障诊断技术,电动机,维修管理,技术

引言:

电动机的出现可以追溯到上个世纪初,随着二次工业革命的快速发展,电动机发挥了巨大的作用。随着我国科学技术、生产技术的突飞猛进,电动机在制造业、工业、农业中发挥了巨大的作用。然而长时间通过工程机械高频率使用电动机,很容易造成电动机故障。因此,故障诊断技术也顺势而生,当前电动机的故障主要包括四种类型,然而该如何进行故障诊断,从而对症下药,是当前专家学者与技术人员共同重视的问题,也是需要持续研究的课题。

1、电动机出现的故障类型分析

转子故障

转子故障主要是因为电动机在长期运行的过程中,由于转子长期处于机械制动的高频率里,所以很容易存在转子故障。电动机转子也包括两个板块:定位轴承、非定位轴承。定位轴承主要是承担转子在高速运转过程中承担负荷力度。在电动机运行的过程中为了避免其他外部作用力造成的损害电动机的情况,还需要安装非定位轴承。

因此,定位轴承与非定位轴承都可能因为电动机遭受了各种作用力造成损害或者损毁的情况,最终导致电动机出现转子故障,这种故障出现是电动机的常见故障之一,也是电动机无法持续运转的关键因素,最终形成断条。

定子故障

定子故障的产生很大程度是因为电动机的外部绝缘体受到了损害导致的;还有一种可能是由于电动机在使用的过程中出现了匝间短路故障。一旦出现了匝间短路则匝间绝缘需要承担暂态过电压。出现这种情况很大程度上是由于电动机长期处于较差环境中,并且持进行高速作业,造成的短路故障、绝缘变形、绝缘损坏的情况下出现的定子故障。

定子故障的产生也是非常常见的,维修人员可以通过故障检修技术来探讨电动机的使用状况、预计电动机的未来使用寿命。定子故障的产生也说明电动机的各个零部件、线路的性能出现了问题。

气隙偏心故障

气隙偏心故障的产生是由于电动机在组装过程中产生零部件、线路出现偏差。出现这种故障一般情况下是由于组装问题、组装人员专业素质导致的。

出现气隙偏心故障的另一原因就是电动机长期作业,在不断震动和高频度使用的过程中造成了零部件松动、轴承故障,或者是因为定子铁芯内径的椭圆度不符合电动机的长期作业指标,从而导致的气隙偏心故障。一旦出现这种故障,很容易产生连锁效应,导致电动机无法正常运作,最终导致定子、转子之间出现了间隙。当电动机无法正常运转时,自然对工程机械的使用造成了困难。

轴承故障

轴承故障的产生原因与气隙偏心故障有相似之处,也是由于零部件长期作业的过程中出现了松动、间隙之后产生的问题。由于轴承承担着电动机运转的多方力量,所以在实际运作的过程中很容易出现温度升高的情况。当温度不断升高,则轴承的径杆因热量影响,产生胀力,从而使轴承松动。电动机的轴承受到转子重力的影响,也必然会导致轴承径杆的表面因为长时间的旋转导致了磨损的情况。再加上轴承圈和轴表面在长期的旋转中呈现机械摩擦,最终导致电动机内部出现热量,最终对轴承造成破坏,导致电动机无法正常、持续的运转。

2、电动机故障诊断技术的应用分析

神经网络诊断

神经网络诊断的方法是目前使用较多的一种诊断方法。神经网络诊断是模仿人类大脑神经元结构,将电动机内部作为大脑结构,从而建立起非线性动力学网络系统,最终由各个单元进行集成式扫描处理,高度并联。

通过互联网数学模拟的能力,进行电动机的故障诊断工作。神经网络诊断方法与传统的计算机诊断方法有所不同。只需要通过软件编制相应的程序,以软件编制任务为基础,高度实行诊断指令,感知与处理电动机内部各个零部件的参数、具体数据,并对比故障之前的.电动机各项零部件的参数,从而扫描出高故障的零部件样本。

通过这种方法,能够更强的感知到电动机内部故障,判断是定子故障还是转子故障,并判断什么区域的零部件出现了松动、磨损的情况。因此,可以看出神经网络诊断主要是将电动机内部各项参数提前掌握,最终实现运算、对比、扫描工作来确诊。

专家系统诊断

专家系统故障诊断与神经网络诊断有相似之处,前者是依靠互联网数字技术,而专家系统诊断则是依靠了人工智能技术。该技术是综合了电动机故障检修相关专家的意见,并结合智能技术检测电动机各项参数,最终进行综合判断。

在使用专家系统诊断时,工程师需要根据自身知识素养来建立诊断模型,通过模型对比,逐一排查的方式,对电动机故障确诊。这种方法是目前较为新颖的检测技术,在建立模型、与专家系统诊断结合的过程中,能够对应解决故障,针对性延长电动机使用寿命,而且综合判断的准确率很高,在快速检测中实现全面排查工作,还能够对电动机有更加系统的诊断报告,帮助相关人员了解与判断电动机状态、未来预计使用寿命。

信号处理诊断

信号处理诊断技术是针对电动机发生故障后发出信号、指令来判断故障情况。除了一些先进的电动机机器设备外,一些企业会在电动机的绝缘设备上安装诊断用信号处理装置,通过安装这种装置,能够完全对应信息处理要求。而维修人员、工程师则根据信号处理诊断技术,对电动机发出的信号时域、时频来进行分析(分析内容是信号的时域、频域、频率分量的变化、信号非平稳时的时变函数判断),从而对相关设备发出的故障进行计算、参数对比,信号处理方式。

混合诊断方法

混合诊断方法也是常见的故障诊断技术,是结合以往的应急型故障诊断方法(该方法需要综合素质较高的工程师、检修工人来进行,结合仪器检测来综合判断电动机故障原因,但由于是肉眼检测和主观判断检测,所以准确率不高)的基础上,结合电动机维修管理工作,实施定期维护、管理工作,来进一步获取电动机内部定子、转子、各项零部件的数据参数,从而避免一旦出现故障会出现明显的数据误差,不利于判断重点损坏区域。当前,这种故障诊断技术随着互联网技术、数字技术的推进,也逐渐走向智能化,方便检修人员实时进行参数对比,方便预判电动机的状态,制定故障维修方案。

3、结束语

本文主要分析的是故障诊断技术在电动机维修管理中的应用,针对目前电动机故障类型进行系统分析与探讨,并针对故障诊断技术的分别具体应用进行详细的探讨,希望通过本文的分析,能够对相关专业知识有更深层次的了解。电动机是工程机械运行的重要组成部分,因此了解故障诊断技术的基础上,能够对相关专业研究有一定的引导作用。

参考文献

[1]刘迎春.故障诊断技术在煤矿机电设备维修中的运用探讨[J].现代工业经济和信息化,2019,9(02):111-113.

[2]王镇林.“电动机故障诊断”实训教学中任务驱动教学法的“微课”应用[J].科技创新导报,2018,15(31):144,146.

[3]孙慧影,林中鹏,刘银丽,李萌.基于随机游走蜂群算法优化的RBF神经网络电动机故障诊断研究[J].水电能源科学,2017,35(08):165-168.

手机电池检测论文

废旧电池的危害性 一粒纽扣电池可污染60万升水,等于一个人一生的饮水量。一节电池烂在地里,能够使一平方米的土地失去利用价值,所以把一节节的废旧电池说成是“污染小炸弹”一点也不过分。 我们日常所用的普通干电池,主要有酸性锌锰电池和碱性锌锰电池两类,它们都含有汞、锰、镉、铅、锌等各种金属物质,废旧电池被遗弃后,电池的外壳会慢慢腐蚀,其中的重金属物质会逐渐渗入水体和土壤,造成污染。重金属污染的最大特点是它在自然界是不能降解,只能通过净化作用,将污染消除。 废旧电池的危害主要集中在其中所含的少量的重金属上 金属种类 危害的表现 锰 过量的锰蓄积于体内引起神经性功能障碍,早期表现为综合性功能紊乱。较重者出现两腿发沉,语言单调,表情呆板,感情冷漠,常伴有精神症状。 锌 锌的盐类能使蛋白质沉淀,对皮膜粘膜有刺激作用。当在水中浓度超过10-50毫史/升时有致癌危险,可能引起化学性肺炎。铅:铅主要作用于神经系统、活血系统、消化系统和肝、肾等器官能抑制血红蛋白的合成代谢过程,还能直接作用于成熟红细胞,对婴幼儿影响甚大,它将导致儿童体格发育迟缓,慢性铅中毒可导致儿童的智力低下。 镍 镍粉溶解于血液,参加体内循环,有较强的毒性,能损害中枢神经,引起血管变异,严重者导致癌症。 汞 它在这些重金属污染物中是最值得一提的,这种重金属,对人类的危害,确实不浅,长期以来,我国在生产干电池时,要加入一种有毒的物质——汞或汞的化合物,我国的碱性干电池中的汞的含量达到1-5%,中性干电池为,全国每年用于生产干电池的汞具有明显的神经毒性,此外对内分泌系统、免疫系统等也有不良影响,1953年,发生在日本九州岛的震惊世界的水俣病事件,给人类敲响了汞污染的警钟。 重金属污染,威胁着人类的健康,人类如果忽视对重金属污染的控制,最终将吞下自酿的苦果,因此,加强废旧电池的回收就日显重要了。

基于视频的人流量监测系统设计与实现 图像水印识别微信小程序设计与实现 基于重力传感器的飞机大战游戏开发 手机平台加减乘除口算训练游戏开发 基于Android平台的个人移动地图软件开发 面向多种数据源的爬虫系统的设计与实现 基于Zabbix的服务器监控系统的设计与实现 基于新浪微博的分布式爬虫以及对数据的可视化处理 基于分布式的新闻热点网络爬虫系统与设计 舆情分析可视化系统的设计与实现 基于大数据的用户画像的新闻APP设计 基于Android平台的语言翻译程序设计与实现 基于SSH的水电信息管理系统的设计与实现 基于SSM的学科竞赛管理系统

废电池的危害:废弃在自然界电池中的汞会慢慢从电池中溢出来,进入土壤或水源,再通过农作物进入人体,损伤人的肾脏。在微生物的作用下,无机汞可以转化成甲基汞,聚集在鱼类的身体里,人食用了这种鱼后,甲基汞会进入人的大脑细胞,使人的神经系统受到严重破坏,重者会发疯致死。著名的日本水俣病就是甲基汞所致。镉渗出污染土地和水体,最终进入人体使人的肝和肾受损,也会引起骨质松软,重者造成骨骼变形。汽车废电池中含有酸和重金属铅泄漏到自然界可引起土壤和水源污染,最终对人造成危害。 废电池污染及其处理已经成为目前社会最为关注的环保焦点之一。国家环保总局科技标准司有关人士认为,随着我国电池的种类、生产量和使用量的不断扩大,废旧电池的数量和种类也在不断增加。废旧电池含有汞、铅、镉、镍等重金属及酸、碱等电解质溶液,对人体及生态环境有不同程度的危害。据了解,其中对人体健康和生态环境危害较大、列入危险废物控制名录的废电池主要有:含汞电池,主要是氧化汞电池;铅酸蓄电池;含镉电池,主要是镍镉电池。 湖南省动力化学电源工程技术研究中心杨毅夫博士告诉笔者,尽管我国一些大型电池生产企业已经开始生产无汞电池,但是大量中小企业生产的仍然是含汞电池,因其价格便宜,应用面广,销售量相当大。铅酸蓄电池主要应用在汽车、电动自行车、通讯备用电源和应急电源等方面。而镍镉电池则普遍用于手机、电动工具、电动玩具等方面,是一种可充电电池。 有关资料显示,一节一号电池烂在地里,能使1平方米的土壤永久失去利用价值;一粒纽扣电池可使600吨水受到污染,相当于一个人一生的饮水量。在对自然环境威胁最大的几种物质中,电池里就包含了汞、铅、镉等多种,若将废旧电池混入生活垃圾一起填埋,或者随手丢弃,渗出的汞及重金属物质就会渗透于土壤、污染地下水,进而进入鱼类、农作物中,破坏人类的生存环境,间接威胁到人类的健康。 人体一旦吸收这些重金属以后,会出现哪些病症呢?据有关专家介绍,汞是一种毒性很强的重金属,对人体中枢神经的破坏力很大,上世纪五十年代发生在日本的震惊中外的水俣病就是由于汞污染造成的。目前我国生产的含汞碱性干电池的汞含量达1%-5%,中性干电池的汞含量为0.025%,我国电池生产消耗的汞每年就达几十吨之多。镉在人体内极易引起慢性中毒,主要病症是肺气肿、骨质软化、贫血,很可能使人体瘫痪。而铅进入人体后最难排泄,它干扰肾功能、生殖功能。 专家们认为,由于电池污染具有周期长、隐蔽性大等特点,其潜在危害相当严重,处理不当还会造成二次污染。据杨毅夫博士介绍,我国沿海某省的一些农民在回收铅酸蓄电池中的铅时,因为回收处理不当,把含有铅和硫酸的废液倒掉,不仅造成了铅中毒,而且使当地农作物无法生长。

废旧电池的危害性 一粒纽扣电池可污染60万升水,等于一个人一生的饮水量。一节电池烂在地里,能够使一平方米的土地失去利用价值,所以把一节节的废旧电池说成是“污染小炸弹”一点也不过分。 我们日常所用的普通干电池,主要有酸性锌锰电池和碱性锌锰电池两类,它们都含有汞、锰、镉、铅、锌等各种金属物质,废旧电池被遗弃后,电池的外壳会慢慢腐蚀,其中的重金属物质会逐渐渗入水体和土壤,造成污染。重金属污染的最大特点是它在自然界是不能降解,只能通过净化作用,将污染消除。 废旧电池的危害主要集中在其中所含的少量的重金属上 金属种类 危害的表现 锰 过量的锰蓄积于体内引起神经性功能障碍,早期表现为综合性功能紊乱。较重者出现两腿发沉,语言单调,表情呆板,感情冷漠,常伴有精神症状。 锌 锌的盐类能使蛋白质沉淀,对皮膜粘膜有刺激作用。当在水中浓度超过10-50毫史/升时有致癌危险,可能引起化学性肺炎。铅:铅主要作用于神经系统、活血系统、消化系统和肝、肾等器官能抑制血红蛋白的合成代谢过程,还能直接作用于成熟红细胞,对婴幼儿影响甚大,它将导致儿童体格发育迟缓,慢性铅中毒可导致儿童的智力低下。 镍 镍粉溶解于血液,参加体内循环,有较强的毒性,能损害中枢神经,引起血管变异,严重者导致癌症。 汞 它在这些重金属污染物中是最值得一提的,这种重金属,对人类的危害,确实不浅,长期以来,我国在生产干电池时,要加入一种有毒的物质——汞或汞的化合物,我国的碱性干电池中的汞的含量达到1-5%,中性干电池为,全国每年用于生产干电池的汞具有明显的神经毒性,此外对内分泌系统、免疫系统等也有不良影响,1953年,发生在日本九州岛的震惊世界的水俣病事件,给人类敲响了汞污染的警钟。 重金属污染,威胁着人类的健康,人类如果忽视对重金属污染的控制,最终将吞下自酿的苦果,因此,加强废旧电池的回收就日显重要了。 回答者: weiguo159 - 首席运营官 十二级 5-11 17:31我们日常所用的普通干电池,主要有酸性锌锰电池和碱性锌锰电池两类,它们都含有汞、锰、镉、铅、锌等各种金属物质,汞、锰、镉、铅、锌,这五种金属物质各有各的害处:如果锰过量蓄积于体内能引起神经性功能障碍,早期表现为综合性功能紊乱。较重者出现两腿发沉,语言单调,表情呆板,感情冷漠,常伴有精神症状。锌的盐类能使蛋白质沉淀,对皮膜粘膜有刺激作用。当在水中浓度超过10-50毫史/升时有致癌危险,可能引起化学性肺炎。铅作用于神经系统、活血系统、消化系统和肝、肾等器官能抑制血红蛋白的合成代谢过程,还能直接作用于成熟红细胞,对婴幼儿影响甚大,它将导致儿童体格发育迟缓,慢性铅中毒可导致儿童的智力低下。镍粉溶解于血液,参加体内循环,有较强的毒性,能损害中枢神经,引起血管变异,严重者导致癌症。在这些重金属污染物中,汞是最值得一提的,这种重金属,对人类的危害,确实不浅,长期以来,我国在生产干电池时,要加入一种有毒的物质——汞或汞的化合物,我国的碱性干电池中的汞的含量达到1-5%,中性干电池为,全国每年用于生产干电池的汞具有明显的神经毒性,此外对内分泌系统、免疫系统等也有不良影响,1953年,发生在日本九州岛的震惊世界的水俣病事件,给人类敲响了汞污染的警钟。 我们用过的电池被遗弃后,电池的外壳会慢慢腐蚀,其中的重金属物质会逐渐渗入水体和土壤,造成污染。重金属污染的最大特点是它在自然界中不能降解,只能通过净化作用,将污染消除。废旧电池的危害主要集中在其中所含的少量的重金属上。废电池正在日益对环境构成严重威胁。有关资料显示:一节电池产生的有害物质能污染60万升水,等于一个人一生的饮水量:一节烂在地里的一号电池能吞噬一平方米土地,并可造成永久性公害。我国是电池生产消费大国,电池的年产量高达140亿节,消费约100亿节,占世界总量的1/3。以全国13亿人口计算,假设每年每人用6节电池,那么这些电池可以污染46800亿立方米的水,相当于中国全年径流总量的倍;也可使7800平方千米土地失去利用价值,这相当于个上海或15个浦东新区的面积。据估计,全球每年约有320亿节废旧电池被丢弃,其危害之大不能不令人触目惊心! 我们应该做到不乱扔废旧电池,如果在大街上见到被扔掉的废旧电池主动捡起,并放入电池回收箱,如果见到别人乱扔废旧电池,我应该告诉他这样做的害处,劝他把废旧电池放入电池回收箱。废电池是个“环境杀手”,它不但污染环境,而且还会进一步影响人类健康。 日益增长的垃圾产量正在使我们居住的星球超负荷运转,层出不穷的公害事件、"垃圾围城"早已为我们敲响了警钟。如何实现无害化、减量化、资源化已是当务之急。"放错了地方的资源"是近年来人们对垃圾的重新认识。实行垃圾分类将使能够回收的垃圾废物实现物尽其用,变废为宝。 就体积和重量而言,废电池在生活垃圾中是微不足道的,但它的害处却非常大,电池中含有汞、镉、铅等重金属物质。汞具有强烈的毒性,铅能造成神经紊乱、肾炎等;镉主要造成肾损伤以及骨疾-骨质疏松、软骨症及骨折。若把废电池混入生活垃圾中一起填埋,久而久之,渗出的重金属可能污染地下水和土壤。 电池在我们生活中的使用量正在迅速增加,已深入到我们生活和工作的每一个角落。WALKMAN、BP机、移动电话、照相机、计算器。目前,全国的电池消费量在70亿只左右。据预测,到2000年仅BP机的电池用量就将达到亿只。这些电池若未得到妥善处理,将直接或间接地危害人们的身体健康。实施并倡导废旧电池分类收集活动为越来越多的人们所认识,并得到越来越多的重视、支持和参与。与其分散污染,不如集中治理。 1998年《国家危险废物名录》上定出汞、镉、锌、铅、铬为危险废弃物: 汞:食用被汞污染的水产品,产生甲基汞中毒,关.头晕,四肢末梢麻木,记忆力减退,神经错乱,甚至死亡,还影响孕妇胎儿畸形。 铅:食用含铅食物,会影响酶及正常血红素合成,影响神经系统,铅在骨骼及肾脏中积累,有潜在的长期影响 镉:进入骨骼造成骨疼,骨骼软化萎缩,易发生病理性骨折,最后饮食不进,于疼痛中死亡。 铬:铬进入体内,分布于肝、肾中,出现肝炎和肾炎病理。 这些电池的组成物质在电池使用过程中,被封存在电池壳内部,并不会对环境造成影响。但经过长期机械磨损和腐蚀,使得内部的重金属和酸碱等泄露出来,进入土壤或水源,就会通过各种途径进入人的食物链。 生物从环境中摄取的重金属可以经过食物链的生物放大作用,逐级在较高级的生物中成千上万地富积,然后经过食物进入人的身体,在某些器官中积蓄造成慢性中毒。日本的水俣病就是汞中毒的典型案例。 40多年前,在日本九洲南部的一个沿海小镇———水俣镇,当地居民中出现了一种奇怪的病。患者开始口齿不清,步态不稳,四肢麻痹,最后全身痉挛,精神失常,在痛苦的折磨中死去。后来染上这种疾患的人越来越多,甚至连猫和海鸟都出现了同样的症状。后来,医务工作者从死者的尸体和海鱼体内发现了有毒的甲基汞,证明了人是吃了被污染的鱼而中毒的。经过调查,原来是当地的日本氮肥工业公司常年向水俣湾排放含汞废水,使海水受到了汞的污染,当地捕捞的海产品中都含有高浓度的甲基汞。 为了恢复水俣湾的生态环境,日本政府花了14年的时间,投入了485亿日元,把水俣湾的含汞底泥深挖4米,全部清除。同时,在水俣湾入口处设立了隔离网,将海湾内被污染的鱼统统捕获进行填埋。曾亲眼目睹过水俣病爆发的日本水俣市市长吉井正澄感慨地说:“经过近半个世纪的不懈努力,我们终于从水俣病的阴影中走出来了,正在建设一个新的水俣市。” 其实最应该回收废旧电池的应该是我国。因为我国目前是世界上干电池产量和销量最大的国家。而且,目前我国有1400余家生产电池的企业,生产及消费可达140亿只电池,而这其中,只有不足够1% 的废旧电池被回收,其余的呢?均被我们随手一扔了之了。 湖南省动力化学电源工程技术研究中心杨毅夫博士说:“尽管我国一些大型电池生产企业已经开始生产无汞电池,但是大量中小企业生产的仍然是含汞电池,因其价格便宜,应用面广,销售量相当大。铅酸蓄电池主要应用在汽车、电动自行车、通讯备用电源和应急电源等方面。而镍镉电池则普遍用于手机、电动工具、电动玩具等方面,是一种可充电电池。人体一旦吸收这些重金属以后,会出现哪些病症呢?据有关专家介绍,汞是一种毒性很强的重金属,对人体中枢神经的破坏力很大。目前我国生产的含汞碱性干电池的汞含量达1%-5%,中性干电池的汞含量为0.025%,我国电池生产消耗的汞每年就达几十吨之多。镉在人体内极易引起慢性中毒,主要病症是肺气肿、骨质软化、贫血,很可能使人体瘫痪。而铅进入人体后最难排泄,它干扰肾功能、生殖功能。 从我做起,从身边每一件小事做起,关爱身边环境、参与废旧电池的分类回收利用是我们每一个人的责任和义务。个人的行为也许微不足道,但把我们每个人的力量联合起来,便足以托起一种文明,一种与自然共生的文明,一种可持续发展的文明。 悲哀的是我们的政府和环保部门都没能尽职,难道环保部门设立几个废旧电池的回收箱有那么难吗???

心电检测论文带翻译

1、窦性心律2、偶发室早3、ST-T变化(注:心率大于100次每分,在模拟Ⅱ、Ⅲ、AVF、V5、V6导联ST段水平压低,T波倒置)4、心率变异性正常

1楼的是无脑翻译。。。

翻译护理论文可以找清北医学翻译,尤其是这一类医学类型的论文,难度比普通论文高很多,所以没有一定的水平我还是建议找机构。

窦性心率。这个正常第二是偶发室早,说明你有早搏,偶发的第三个ST-T变化,当你心率大于100次每分的时候雨ST段变化,考虑心肌缺血。心率异性正常。总体来说问题不大。

相关百科

热门百科

首页
发表服务